Presentation + Paper
21 October 2021 Simulation analysis of mechanical performance of laser catheter in ELCA operation
Author Affiliations +
Abstract
Excimer Laser Coronary Atherectomy (ELCA) uses 308nm laser to eliminate coronary atherosclerosis. It has a good therapeutic effect in diseases such as poor stent expansion, moderate calcification, and acute myocardial infarction. The laser catheter enters the patient's body during the operation and transmits the laser to the lesion, which plays an important role in the success of the operation. In this paper, the finite element simulation analysis of the mechanical properties of the laser catheter is carried out, and innovative optimization design is carried out on this basis. The paper first analyzes the laser catheter composite material, establishes its torsion, compression, and bending finite element model, and analyzes the influence of the microstructure on the mechanical properties of the laser catheter. Set different parameters for the helix angle, number and diameter of the optical fibers in the laser catheter, and simulate the stress conditions under three kinds of loads. The results show that the three variables have a great influence on the stress and deformation of the laser catheter composite material. Then a finite element model of the coronary artery of the heart is established, the laser catheter's movement in the coronary artery is simulated by LS-DYNA, and the effect of the laser catheter's diameter, wall thickness and elastic modulus on the stress of the laser catheter is analyzed. It is found that the laser catheter is subject to greater stress at the bending part of the aortic arch, and the diameter, wall thickness and elastic modulus of the laser catheter have a significant influence on the stress and advancing distance of the laser catheter. Finally, on the basis of simulation analysis and comprehensive consideration of various influencing factors, the parameters of the laser catheter are designed. In order to meet the stress requirements of different positions of the laser catheter, a catheter design with variable fiber helix angle is proposed.
Conference Presentation
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Lei Su, Bowen Liao, Yichun Wang, Hongzhang He, Han Wu, and Xiuquan Ma "Simulation analysis of mechanical performance of laser catheter in ELCA operation", Proc. SPIE 11900, Optics in Health Care and Biomedical Optics XI, 119000X (21 October 2021); https://doi.org/10.1117/12.2600427
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical simulations

Arteries

Optical fibers

Composites

Fiber lasers

Finite element methods

3D modeling