Presentation + Paper
4 April 2022 Single-shot quantitative x-ray imaging using a primary modulator and dual-layer detector: simulation and phantom studies
Linxi Shi, N. Robert Bennett, Adam S. Wang
Author Affiliations +
Abstract
Conventional x-ray imaging provides little quantitative information due to scatter, beam hardening, and overlaying tissues. A single-shot quantitative x-ray imaging (SSQI) method was previously developed to quantify material-specific densities in x-ray imaging by combining the use of a primary modulator (PM) and dual-layer (DL) detector. The feasibility of this concept was demonstrated with simulations using an iterative patch-based method. In this work, we propose a new algorithm pipeline for SSQI that enables accurate quantification and high computational efficiency. The DL images contain four measurements that are obtained behind the unattenuated and partially attenuated regions of the PM of each layer. Using the low-frequency property of scatter and a precalibrated material decomposition (MD), four unknowns (i.e., two scatter images and two material-specific images) are jointly recovered by directly solving four equations given by the four measurements. We tested this algorithm in simulations and further demonstrated its efficacy on chest phantom experiments. Through simulation, we show that the new method for MD is robust against scatter. Its performance improves with smaller PM pitch size and smaller focal spot blur. The RMSE in material-specific images compared to ground truth reduces by 52%-84% versus without scatter correction. For our experimental study, we successfully separated soft tissue and bone. The computational time for processing each view was ~8 s without optimization. The reported results further strengthen the potential of SSQI for widespread adoption, leading to quantitative imaging not only for x-ray imaging but also for real-time image guidance or cone-beam CT.
Conference Presentation
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Linxi Shi, N. Robert Bennett, and Adam S. Wang "Single-shot quantitative x-ray imaging using a primary modulator and dual-layer detector: simulation and phantom studies", Proc. SPIE 12031, Medical Imaging 2022: Physics of Medical Imaging, 1203106 (4 April 2022); https://doi.org/10.1117/12.2611591
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-ray imaging

Modulators

Tissues

Bone

Calibration

X-ray computed tomography

X-rays

Back to Top