Proceedings Volume 1201

Optical Fibers in Medicine V

cover
Proceedings Volume 1201

Optical Fibers in Medicine V

View the digital version of this volume at SPIE Digital Libarary.

Volume Details

Date Published: 1 July 1990
Contents: 16 Sessions, 80 Papers, 0 Presentations
Conference: OE/LASE '90 1990
Volume Number: 1201

Table of Contents

icon_mobile_dropdown

Table of Contents

All links to SPIE Proceedings will open in the SPIE Digital Library. external link icon
View Session icon_mobile_dropdown
  • Laser-Tissue Interaction
  • Tissue Fluorescence Guidance Techniques
  • Angioscopy/Ultrasound Guidance Techniques
  • Laser Balloon Angioplasty/Arterial Welding
  • Laser Angioplasty Basic Science and New Devices
  • Clinical Laser Vascular Medicine
  • Fibers in Invasive Treatments/Surgery
  • Optical Fibers and Sensors in Medical Diagnostic
  • Direct Measurements with Optical Fibers
  • Raman Applications in Fiber Diagnostics
  • Diagnostic Systems II
  • Catheter-Based Medical Diagnostics and Imaging
  • Spectroscopic Imaging
  • Fiber Optic Imaging
  • Novel Techniques
  • Laserthermia and New PDT
  • Diagnostic Systems II
  • Raman Applications in Fiber Diagnostics
Laser-Tissue Interaction
icon_mobile_dropdown
Enhanced ablation of human atheroma using a copper vapor laser
Simon Ashley, Stephen G. Brooks, Helena Wright, et al.
The most suitable type of laser and delivery system for arterial recanalisation remains a matter of controversy. Atheroma demonstrates preferential absorption of laser light relative to normal vessel wall at wavelengths in the region of SOOnm. This phenomenon may be useful in laser angioplasty. A low power commercial quasi-continuous-wave copper vapour laser (CVL) licensed for photodynamic therapy (Oxford Lasers model CUb-A, Oxford, U.K.), emits light at 2 wavelengths - 51mm (green) and 578nm (yellow) [green/yellow ratio 2:1]. This laser may also be used to pump a dye laser producing a tunable output from 530-900nm. The output was coupled to a 1 mm diameter bare quartz optical fiber, and the effects of these wavelengths on atheroma were studied. Perforation thresholds in normal vessel were determined initially. Subsequently, tissue craters were created in sections of normal human femoral artery and in white fibrous atheromatous artery, using a total of 8 J of laser energy delivered with the fiber in contact and perpendicular to the tissue. Crater dimensions were determined histologically in 10 sections from each group, using an optical graticule. Results:- The dye laser pumping produced insufficient power output to achieve tissue ablation. The crater depth, width, and volume, in normal (N) and atheromatous (A) arterial wall achieved with the CVL were statistically compared using a Paired Student's t-test. Crater depth (mm) [mean (s.e.)]: N 0.91 (0.06), A 0.69 (0.05), p
Optical density of healthy human arterial vessel wall and atheromatous plaque as a basis for pulsed laser angioplasty
Hans-Joachim Schwarzmaier M.D., Thomas Hennig, Peter Betz M.D., et al.
Transmissions spectra of healthy human arterial vessel wall (intima, media, adventitia), lipid plaque as well as calcified plaque were obtained from 245 autopsy specimens (25 patients) by znicrospectrophotometry (25 jim sections, wavelength 240 nm - 1070nm). Lipid plaques showed moderately increased optical density over normal tissue in the visible and near infrared spectral range with maximal values in the blue spectral range (440 nm to 530 nm). At these wavelengths, extinction was about a factor of S compared to intima, a factor of 3 higher than in media, and a factor of 7 higher with respect to adventitia. Over the whole spectral range investigated, calcified plaque exhibited a significantly higher optical density compared to all layers of normal vessel wall. The maximum differences were found between 300 and 450 am for intima (6 to 7 fold), between 440 and 1070 for media (3 fold) and above 550am for adventitia (10 to 12 fold).
Tissue Fluorescence Guidance Techniques
icon_mobile_dropdown
Laser-induced tissue autofluorescence versus exogenous chemical probe induced fluorescence as an arterial layer detection method: a comparative study
The goal ofihis sludy was o develop a reliable laser inducedfluorescence specira analysis system using the 308nm Excimer Laser as an ablaiion andfluorescence inducing source. During our analysis we also aflempled lo determine whether exogenous chloroeiracycline hydrocloride (CTC) increased the discrimination capacity of the LIFS system. We then assessed the ability of CTC to improve the detection of the boundary between atheroma and normal media.
Changes in total fluorescence intensity resulting from laser penetration depth in human arteries
Biqing Ye, George S. Abela M.D.
The dependence of total fluorescence intensity emitted from normal artery on laser excitation power (30 mw - 230 mw) at 514 nm was studied. Variations in fluorescence profile and total fluorescence intensity were explored for normal arteries (n=13) and fibrous atheromas (n=32) using 488 nm laser excitation at 30 mw and 514 nm laser excitation at 40 mw respectively. In addition to changes in fluorescence profile, the total fluorescence intensity was considerably different for normal artery specimens and fibrous atheromas. The total fluorescence from normal artery was found to be twice as great as that from fibrous atheroma. A theoretical multi-layer model based on Beer's law was developed. This analysis was used to show that changes in total fluorescence intensity may be due to the variance in laser penetration depth in tissue when an incident laser of constant intensity was used. With the known absorption coefficients for plaque and normal wall at 488 and 514 nm excitation the calculations of total fluorescence intensity were made at tissue depths when the incident beam reached 1 mw. Thus according to the model, the penetration depth in normal artery is 1.70 mm and in fibrous atheroma is 0.85 mm at 488 nm laser excitation and 30 mw. The ratio of the total fluorescence from normal artery to that from atherosclerosis was calculated to be 1.8 multiplied by the ratio of their fluorescence coefficients. Also, the laser penetration depth in normal artery increased with the increase of the laser excitation power at 514 nm. The computed total fluorescence intensity was highly correlated with the experimental results obtained from tissue fluorescence (R = 0.996). Thus experimental results obtained from fresh necropsy normal and atherosclerotic
Detection of calcified plaques before generation of laser-induced shockwaves: dye laser, alexandrite laser
M. Scheu, Ralf Engelhardt, Jan H. Goethlin M.D.
We investigated the possibility to use the intensity of the time resolved laser induced fluorescence signal (LIF) to discriminate between normal intima and calcified lesions by use of a pulsed dye laser (495 nm, 590 nm) and an alexandrite laser (750 nm). Experiments were performed for 83 specimens consisting of normal intima, fibro-fatty plaques, yellow--white calcified and dark hemmorhagic calcified plaques. At 495 nm an obvious intensity discrimination level was found, 39 of 40 calcified plaques were correctly classified.
Angioscopy/Ultrasound Guidance Techniques
icon_mobile_dropdown
Percutaneous angioscopy of sapphire-tip laser angioplasty
Michael Ralph Rees, Abdurrazak A. Gehani, Simon Ashley, et al.
Percutaneous angioscopy using flexible steerable 2.2mm diameter and non-steerable 1.4 mm. angioscopes together with a guiding catheter system was used to evaluate the endoluminal appearances before and after laser angioplasty using ND-YAG laser energy modified by 1.8,2.2 and 3.0 mm rounded sapphire probes in 8 patients with occlusive peripheral vascular disease. Prior to laser angioplasty, angioscopy demonstrated endoluminal findings that were not detected by angiography. Following laser angioplasty it was observed that the probes predominantly recanalised via the true lumen of the vessel with charring and other evidence of thermal damage being infrequent (3/8 cases) . Where the procedure had been painful, angioscopy demonstrated significant sub-intirnal dissections (2/8 cases) . Angioscopy provides valuable clinical information to support in-vitro experimental evidence of the mode of action of sapphire probes.
Continuous wave laser angioplasty using IR (CO) or UV (Ar) lasers under visualization by a thin endoscope: in-vitro and in-vivo animal experiments
Tsunenori Arai, Akira Suda, Masato Nakagawa M.D., et al.
We studied an use of the continuous wave(cw) lasers(infrared and u1tra-violet) to the laser angioplasty by in vitro and an animal experiment in vivo. The use of the cw lasers provides an advantage of the reliable laser energy delivery by a thin flexible fiber. We had already reported the ablation characteristics and the fiber delivery capability of the CO laser. In this paper, we describe an another interesting cw laser for the laser angioplasty. The ablation characteristics of the uv Ar laser of which wavelength was approximately 350nm was studied. To develop an operation procedure of the angioscopic laser angioplasty, the animal experiments in vivo have been done under a visualization by a thin laser angioscope catheter with the CO laser irradiation. The advantage of the visualization during the laser angioplastic procedures are discussed.
Angioscopy by a new percutaneous transluminal coronary angioscope
Masami Sakurada, Kyoichi Mizuno, Akira Miyamoto M.D., et al.
We developed a new percutaneous transluminal coronary angioscopic catheter for visualization of coronary artery.This angioscopic catheter has an inflatable balloon at the distal tip and one - directional angulation mechanism.We performed percutaneous transluminal coronary angioscopy during cardiac catheterization cosecutively in 155 patients. With this angioscope , we could get good'-'fair visualization in 81%(131 of 162 lesions)without major complications.We could investigate the endothelial macropathology of ischemic heart disease such as unstable angina and acute myocardial infarction.
Intraluminal ultrasound guidance of transverse laser coronary atherectomy
H. Thomas Aretz M.D., Michael A. Martinelli, Earl G. LeDet, et al.
A coronary laser atherectomy system combining laser delivery and ultrasonic imaging capability is described. The system is being developed by Intra-Sonix, Inc. to treat severe stenoses. The imaging system provides the clinician with the guidance needed to remove substantial plaque without perforation. The ultrasound transducers and laser optics are mounted in a small (less than 4 F), flexible catheter, that is deliverable over a standard guidewire (0.016 inch). The laser and ultrasound beams are directed at the artery wall to permit debulking of lesions and ultrasonic depth profiling of the tissue structure throughout the thickness of the artery. This allows the physician to determine the level of therapy to be applied and to monitor the plaque removal as the therapy progresses. The precise location of the ultrasound and laser beams in the artery is determined by a navigation system. Navigation data are processed electronically in conjunction with ultrasound data to produce real-time cross-sectional and longitudinal images of the artery wall at selected locations, which are updated as the catheter progresses through the vessel lumen. Results of in vitro tests on human atherosclerotic arteries and early in vivo experiments in a canine-human xenograft model showing image construction and radial laser delivery are discussed.
Laser Balloon Angioplasty/Arterial Welding
icon_mobile_dropdown
Management of failed angioplasty with laser balloon angioplasty
Ronald D. Jenkins M.D., J. Richard Spears M.D.
Laser balloon angioplasty (LBA) is a technique for improving the post angioplasty result by the radial diffusion of continuous wave Neodymium:YAG laser energy to the arterial wall during the final inflation of percutaneous transluminal coronary angioplasty (PTCA). Potential mechanisms of luminal improvement include sealing of dissections, reduction of arterial recoil, desiccation of thrombus, and reduction of thrombogenicity of tissues at the luminal surface. These effects are helpful in the management of failed PTCA as defined by the presence of a greater than 50% stenosis after conventional PTCA. Preliminary data suggest that LBA may be safe and effective for the treatment of abrupt closure, with a majority of patients successfully avoiding emergency coronary artery bypass surgery. Similarly, a cohort in which the residual post-PTCA luminal diameter was less than 50% of reference diameter (n=13) was subsequently treated with LBA and demonstrated uniform success in improving luminal diameter, with a mean increment of 0.9mm. Data on the long-term clinical outcome of this cohort is encouraging.
Clinical coronary laser balloon angioplasty: effect on ergonovine responsiveness
Timothy J. Bowker, Nigel P. Buller, Morag W. Pearson, et al.
Laser balloon angioplasty involves delivery of continuous wave Nd-YAG laser energy radially from the surface of a specially designed a.ngioplast.y balloon directly to the luniirial surface of an arterial segment immediately after it.s succeasfu] dilatation by conventional balloon angioplasty, the purpose being to fuse loose flaps and disrupted atheroinatous plaque thermally hack against the arterial wall and to reduce elastic recoil and smooth muscle proliferation, in an attempt to prevent re stenosis . Ergonovirie stimulates arterial wall smooth muscle, normally causes arteries to constrict and is used in the diagnosis of coronary artery spasm. Three patients were treated with laser balloon angioplasty, each receiving 380 3 over 20 seconds (30 W for 5 a, 18 W for 5 s & 14 W for 10 5) . The minimum lumirial diameter of the treated arterial segment was measured angiographically before and after conventional balloon angioplasty, immediately after laser balloon angioplasty and again 1 month later both before and after ergonovine was given. The measurements were (respectively, in mm): 1.03, 1.71, 1.85, 2.37 and 2.37 in patient 1; 0.30, 1.54, 1.85, 2.07 and 2.11 in patient 2; and 0.98, 1.76, 2.27, 2.40 and 2.40 in patient 3. The before and after ergonovire measurements were almost identical, suggesting that laser balloon angioplasty abolishes ergonovine responsiveness for at least up to one month following the procedure, and thus might be of use in treating coronary artery spasm which is resistant to medical therapy.
Application of CO laser for laser balloon angioplasty
Akira Miyamoto M.D., Masami Sakurada, Kyoichi Mizuno, et al.
CO laser may be efficient for thermal fusion of intima of arterial wall without adventitial tissue damage because of high tissue absorption. To investigate the efficacy of CO laser as a laser bam for laser balloon angioplasty (LBA). CO laser was irradiated to aortic tissue through 3Oim polyethylene membrane and tissue temperature was measured by a thermistor. At 2Owatt/cm2 200joules/cm2 continuous laser exposure (CE), tissue temperature was above 100°C within a depth of 1mm and rapidly decreased to 60 °C or below between 2 and 3mm in depth. Moreover, adventitial temperature could be decreased by changing duty ratio (exposure duration/interval) of intermittent laser exposure (IE) despite of the same laser energy. Light microscopy showed high degree of medial coagulation necrosis in CE, however thermal coagulation was observed only at the surface of intima of aortic tissue in IE at duty ratio 1 / 2. These findings suggested CO laser could coagulate intimal layer with less deep thermal damage compared to Nd- YAG laser and that IE was better for superficial welding than CE at the same energy. We concluded that CO laser might be more efficient as a laser beam for LBA than Nd-YAG laser.
Laser welding for coronary artery anastomosis: techniques, temperature profiles, and the role of chromophores
Stephen G. Brooks, Simon Ashley, Abdurrazak A. Gehani, et al.
Laser vascular anastomosis is a developing technique which aims to employ the thermal effect of laser energy to achieve tissue fusion with minimal thermal damage. The tissue temperature necessary to achieve effective bonding is debated and must be related to the mechanism of fusion. Enhanced energy absorption at the anastomosis using chromophore (CR) dyes may improve technical success. Over 300 arteriotomies in porcine coronary arteries were welded in vitro using Argon (488/5 14 nm) and Nd:YAG (1060 nm) lasers with or without chromophore. Bursting pressures under saline infusion were measured and tissue temperatures during welding recorded using infrared thermal imaging. Results were as follows. Argon - CR (mmHg) [mean (s.e.)]: 249 (28). Argon + CR: 280 (22). Nd:YAG - CR: 1 5 1 (23). Nd:YAG + CR: 27 1 (30). The use of chromophore therefore increased the weld bursting strength for both lasers but this effect was statistically significant only for the Nd:YAG (p< 0.05, oneway ANOVA). Argon welds were stronger than Nd:YAG welds (p<0.O5) but this difference lost significance when chromophore was used. All welds required temperatures of around 100 degC to be effective and was inconsistent below 80 degC. In conclusion, vascular anastomoses produced by laser can withstand suprasystolic pressures. The effect of chromophore is to improve weld strength and consistency and furthermore, to visibly reduce thermal damage and facilitate beam aiming. These are considerable technical advantages.
Laser Angioplasty Basic Science and New Devices
icon_mobile_dropdown
Fiber optic laser angioplasty probe with optical steerability
Douglas A. Christensen, D. L. Decker-Dunn, G. Michael Vincent M.D.
We have designed and bench tested an optically steerable fiberoptic probe for use in laser angioplasty. The unique feature of this design is the use of a gradient-index (GRIN) lens attached to the distal end of a seven-fiber bundle. By selecting which fiber of the bundle is illuminated by the source, the radiation pattern from the probe's tip may be steer&l either straight ahead or off-axis in one of six angularly biased directions. The probe may also be used to collect scattered light (for example, fluorescence) for the purpose of detecting the spatial distribution of the plaque on the vessel's walls.
Effect of mechanical force with laser-thermal probes on the vaporization of atherosclerotic plaque
John W. Caravello, George S. Abela M.D., Gerald R. Barbeau M.D., et al.
To define the effect of mechanical force during vaporization of atherosclerotic tissue, commercially available thermal and thermal-optical laser probe systems were used to irradiate fresh homogenous atherosclerotic cadaveric human aorta in air. Force was applied as perpendicular pressure ranging from 5 to 40 gm at 2.0, 3.0, or 4.0 watts. Probe vaporization rate [VR] (tissue penetration in mm/sec) and vaporzation efficiency [VE] (volume of tissue vaporized/joule) were calculated for each irradiation. Probe temperatures [PT] were monitored using K-type thermocouples. The volume of carbonization surrounding each crater was used to quantify the amount of thermal damage [TD]. The following observations were made using these probe systems: (1) For the thermal system, VR was found to be constant with regard to force, but rose abruptly with increasing power from 3 to 4 watts. No significant increase in VE was observed with increasing force (ANOVA, P < 0.10). PT and TD also showed no dependence on force. (2) For the thermal-optical system, VR increased with applied force up to 30 gm, but reached a plateau or even decreased at greater forces. VE increased significantly at forces less than or equal to 20 gm (ANOVA, p < 0.05); however, at higher forces VE began to decrease. PT and TD both decreased with increasing probe force. Comparing the two probe systems revealed that VR and VE were significantly greater (ANOVA, p < 0.0001 and - < 0.005, respectively) but TD was not significantly smaller (ANOVA, p < 0.10) for the thermal-optical system compared to the thermal system. Within the range of energy settings evaluated, increasing mechanical force consistently enhanced vaporization up to 30gm of pressure when using the thermal-optical probe. Using the thermal probe system, this effect occurred abruptly when the power was increased. Thus, mechanical force seems to enhance laser recanalization, however, if much force is applied vaporizatioin efficiency starts to drop.
Optically modified fiber tips penetrate only when "dirty"
Rudolf M. Verdaasdonck, E. Duco Jansen, F. C. Holstege, et al.
Optically modified fiber tips are under investigation ox already in use clinically for the recanalization of totallyocciuded arteries. It has not been determined to what extent their mechanism of action is optical, thermal and mechanical. We studied a 2.2 mm diameter, rounded Sapphire Contact Probe (SLT, MTR 1.5) and a 1.5 mm diameter ball-shaped fiber (ACS) coupled to a continuous wave Nd-YAG laser using 1 second pulses. The probes were positioned perpendicular to homogeneous porcine fatty tissue samples in plasma using preset axial forces. Penetration depth per pulse and temperature of the collar of the probes were measured in relation to the force. Starting with new, clean probes no tissue penetration was achieved using forces up to the equivalent of 105 gr and powers up to 25 W for 10 s. On purpose, the probes where exposed to high powers in plasma until a coagulum was formed on the tip. After cleaning, a ring of carbonized particles deposited on the surface of the probe bordered the exit window of the beam on the tip. The power absorbed by the probes increased from 5 to 32 %. Tissue penetration with 'dirty' probes was force dependent. For sapphire contact probes it was 1.2 - 2.9 mm/pulse (1 mm diameter spot, 15 W, 1 s) in the force range of 23 - 105 gr. For the ball shaped fibers it was 2.7 10 mm/pulse (0.4 mm diameter spot, 10 W, 1 s) in force range of 23 - 35 gr. The optically modified fiber tips studied did not penetrate tissue by absorption of the Nd-YAG beam by the tissue only. Tissue penetration started when part of the laser beam was absorbed by pollution on the surface of the probe creating a 'hot tip'. Tissue penetration was force dependent due to the smaller diameter of the ablative beam in comparison to the diameter of the probe. Thus, the recanalization mechanism of both probes is partly mechanical.
Thermal and optical behavior of sapphire fiber tips for laser angioplasty
Simon Ashley, Stephen G. Brooks, Abdurrazak A. Gehani, et al.
Atraumatic rounded contact probes made from artificial sapphire crystal were developed for general laser surgery and are currently being evaluated for use in percutaneous laser angioplasty utilising continuous wave (cw) Nd-YAG energy (1064nm). The thermal and optical characteristics of five different types of rounded sapphire probe [Surgical Laser Technologies (SLT) - SMTR (1.8mm), MTh (2.2mm), MTRL (3.0mm); Living Technology - LT (2.2mm), OS (2.2mm)] were investigated and related to efficiency of contact ablation of arterial wall in vitro. The sapphire probes were mounted on catheters containing a 0.6 mm quartz optical fiber, coupled to a cw Nd-YAG laser. All probes produced a similar beam profile but there was some variation in their forward transmission of energy (54-85%).Probe heating occurs due to energy absorption within the sapphire and was measured in air by infrared thermography. There was a high temperature gradient from the front surface of the sapphires to the probe rim. But, at energy settings used clinically (10 J pulses, 10 Watts for 1 second) the SMTR, MTR, and MTRL probes exhibited a higher mean temperature rise (63-74 C) than the OS and LT probes (20 C) [3-way ANOVA p
Cardiomyoplasty with the use of different laser methods
Alexander Krakowsky, Valeri S. Chekanov, K. Shatalov, et al.
The first Soviet fundamental Investigation of the use of a skeleta]. aut&xnuscle as a functional active unit in the left ventricular aneurysm resection was carried out. The investigation was baica11y experimental; it was performed on 3 groups of 90 mongrel dogs. The authors refer to the first clinical experience. A cardiosynchronized , distance-guided, implantable neuromyostimulator working in the cardiosynchrcnized regimen, elaborated together with the Moscow Engeneering-Physical Institute is presented for the first time. A complete evaluation of the essential parämaters of the left ventricular myocardial contractile capacity, based on the intracardiac pressure registration in experimental animals was performed. The obtained data permit to consider the use of a skeletal automusole as a help to the cardiac function in left ventricular aneurysm as absolutely justified, because the stimulated automuscie can form a blood presure, adequate for the circulation support.
Fluid-core optical transmission for laser angioplasty
Optically transparent fluids were investigated as a means of transmitting laser energy (LE) in laser angioplasty catheters as an alternative to fused silica fibers. A catheter was constructed which transmits LE through a flowing stream of iodinated contrast media. LE is launched into a stream of contrast media and is internally reflected by a lower index of refraction cladding-providing transmission efficiency of 75%. As the stream exits the catheter, blood acts as an optical cladding and allows transmission 1 cm distal to the catheter tip. The low pressure stream removes intervening blood and provides an atraumatic surface for light interaction with target tissues. Fluoroscopy of the contrast stream allows real-time visualization of the catheter, the site of LE delivery and distal vasculature. We conclude that a fluid-core laser angioplasty catheter can transmit high peak-power laser energy and offers simplicity, blood removal, improved flexibility and real-time imaging during intravascular LE delivery.
Systematic assessment of the factors influencing the efficacy of laser thermal angioplasty in the coronary circulation
Bruce E. Keogh, Filippo Crea M.D., Terence Bull, et al.
These studies indicate that perfusate, vessel wall temperature, plaque geometry and plaque composition are all determinants of successful recanalization. Furthermore, these are important considerations for all types of laser coronary angioplasty and provide guidelines for future technological development.
Clinical Laser Vascular Medicine
icon_mobile_dropdown
Early results of pulsed dye laser angioplasty with integral ball-tips in long femoral occlusions
Alan Murray, David C. Mitchell, Richard F. M. Wood M.D.
A Pulsed Dye laser together with specifically designed integral ball-tipped optical fibres have been used for the primary recanalisation of femoropopliteal vascular disease in 25 limbs of 23 patients. All patients had complete occlusions of the vessels ranging from 8-49cms in length (mean 22cms), having presented with critical ischaemia (18) or severe claudication warranting operative intervention (5). Pedal ulceration was present in 8 limbs and digital gangrene in 4. The laser produced visible light at 480nm in lOOmJ/lus pulses, at a frequency of 10-20Hz. The energy delivery device comprised a smooth atraumatic ball-tip constructed from the glass of the optical fibre, which was loaded retrogradely into a standard balloon angioplasty catheter. The device was introduced through a common femoral artery cutdown. Angiographic recanalisation was achieved in 22 of the 25 limbs with a mean energy of 280J(range 68-727J) and in each case the channel created by the laser fibre was augmented by balloon angioplasty. Technical failure occurred in three cases, caused by a wall dissection, persistent side-branch entry and incomplete lesion penetration respectively. Eighteen of procedures (72%) were clinically successful with marked symptomatic improvement. Of the four angiographic successful but clinical failures, acute occlusion within 48 hours occurred in 2 diabetic patients with very poor run-off and distal gangrene. The third case failed acutely due to a technically inadequate balloon dilatation and the fourth patient failed to improve symptomatically due to widespread with segmental tibial vessel disease below a successful recanalisation. Over a mean follow-up period of 7 months, three patients died of myocardial infarction. Twelve of the 23 patients (52%) remain well with patent vessels. These early results demonstrate the efficacy of pulsed dye laser angioplasty using ball-tipped optical fibres.
Intraoperative XeCl excimer laser coronary artery endarterectomy: one-year follow up in ten patients and technical improvement of the method
Sigrid Avrillier, E. Delettre, J. L. Bussiere, et al.
We present the results of 12 XeC1 laser coronary artery endarterectomies performed in 10 patients during CABG surgery. The results are very encouraging and led us to the developement of a new and more efficient laser catheter &livery system which is described in the second part of this paper.
Percutaneous excimer laser coronary angioplasty
Tsvi Goldenberg, William B. Anderson, Frank Litvack M.D., et al.
Two hundred ten percutaneous excimer laser coronary angioplasty cases have been done using a XeC1 excimer laser system operating at 308 nanometers. The overall results of the cases are encouraging. The acute clinical success rate is approximately 85%,with a low rate of complications.
Report of clinical experiences on excimer laser angioplasty in coronary and peripheral arteries
Riccardo Viligiardi, V. Gallucci, Roberto Pini, et al.
Results and operative problems of excimer laser angioplasty in human arteries will be presented. They pertain to a clinical experience about the coronaric district in association with A.C. by-pass procedure and in the iliac and femoralpopliteal districts with a percutaneous approach.
Progress in the development of laser endarterectomy
John Eugene, Michael W. Berns
Argon ion laser endarterectomy has progressed from the laboratory to a clinical trial for peripheral vascular disease and now to a clinical trial for carotid artery disease. In the first 18 months of clinical trials, 14 peripheral laser enarterectomies and 4 carotid laser endarterectomies were performed. Low power argon ion laser radiation (1.0 W) was used for all operations. The peripheral vascular reconstructions resulted in symptomatic relief and all carotid patients are neurologically intact. There were no arterial injuries from laser radiation and all arteries showed smooth endarterectomy surfaces with welded end points. The initial clinical studies show that laser endarterectomy can be used for carotid artery disease as well as peripheral arterial disease with low power argon ion laser radiation.
Laser angioplasty using a lensed-fiber delivery system and a pulsed Nd:YAG laser: early clinical results
Christopher J. White M.D., Stephen R. Ramee M.D., Juan E. Mesa M.D., et al.
We performed a clinical trial to evaluate the safety and efficacy of a unique lensed-fiber delivery system with a pulsed Neodymium-yttrium aluminum garnet (Nd-YAG) laser in patients with atherosclerotic peripheral vascular disease. The lensed-fiber consists of a spherical silica lens, 1 .5 mm in diameter, mounted at the distal tip of a 300 im silica optical fiber. The Nd-YAG laser is pulsed at 10 Hz, and we delivered 0.5 J/pulse with a pulse duration of 100 msecs in 2- to 5-second bursts. Successful recanalization of stenoses or occlusions was obtained in 9 of 10 patients and was manifested by improvement in blood flow as measured angiographically and with ankle-brachial blood pressure index improvement (> 0. 15). There were no arterial perforations or dissections associated with the laser angioplasty. All successfully recanalized patients required adjunctive balloon angioplasty to obtain a satisfactory reduction in luminal diameter stenosis of the treated artery. We conclude that this unique delivery system and the pulsed Nd-YAG laser are a safe and effect method of recanalizing arterial stenoses not amenable to conventional balloon angioplasty alone.
Percutaneous peripheral laser angioplasty with a pulsed Nd:YAG laser and sapphire tips
Jan Kvasnicka, Frantisek Stanek, Frantisek Boudik M.D., et al.
Percutaneous transluminal laser angioplasty with a pulsed Nd:YAG laser (1,064 nm wavelength, 100 jig pulse duration, up to 0.4 J per pulse, 10 Hz repetition rate) coupled to optical fibers with sapphire tips of 1.8, 2.2 and 2.9 mm diameter was performed in 17 chronic occlusions of iliac, femoral, popliteal and fibular arteries in 15 patients. Clinically the procedure was successful in 14 cases. The probe formed a primary channel of at least 2.0 mm width which was further dilated by conventional balloon catheter. Ankle/brachial systolic pressure index (ABPI) increased from 0.46 0.13 to 0.84 0.21 after the procedure. Two failures were due to an extensive dissection which occurred after balloon angioplasty and resulted in an early reocclusion. In the remaining case a balloon catheter could not be introduced through the 30 cm long primary channel which reoccluded shortly after the recanalization. The initial patency rate was 82 % and in 5 patients followed for more then 6 months the ABPI showed only a minor decrease. These first results are encouraging and it is likely that this method could become an important alternative to conventional balloon angioplasty.
Fibers in Invasive Treatments/Surgery
icon_mobile_dropdown
Overview of challenges/problems in employing optical fibers for invasive treatments/surgery
As the lead paper for the session describing new results in the application of fiber optic systems to invasive treatments and surgery, this paper presents an overview of the basic properties of optical fibers and the advantages of using them in such applicaticns along with the challenges and problems which need to be addressed in designing the systems.
Technical prerequisites for the interstitial thermotherapy using the Nd:YAG laser
Stefan Frank F. Hessel, Klaus H. Frank
The laser has established a strong position in the field of tumor surgery. The endoscopic modalities of tumor coagulation in particular have been developed so far, that in some cases even tumors in anatomically difficult locations or inoperable tumors can be coagulated interstitially. The Nd:YAG laser is well suited to this technique due to its good coagulation properties and the transmissiblity through flexible fibers. Application systems such as the bare fiber, the diffuse emitting fiber, the frosted sapphire tip and a newly developed circumferentially emitting fiber, the so-called ITT light guide, differ widely with respect to beam characteristics, power density at the fibertissue transition, maximum laser power, geometrical dimension, flexibility, adhesive properties and compatibility with MRI diagnostics and MRI therapy control. In vitro experiments as well as first results from animal trials and clinical experiments prove that the Nd:YAG laser and the new ITT light guide provide a simple and reliable technique for interstitial thermo therapy.
Focusing of high-power laser beams transmitted through optical fibers
Pascal O. Rol, Juerg Wyser, Peter F. Niederer
In recent years laser technology has undergone a tremendous development. New laser sources have become available for routine applications which are now being introduced in various fields of medicine. In particular, excimer, pulsed dye, new solid state (Er:YAG, Ho:YAG, Alexandrite) and diode lasers exhibit promising characteristics in view of therapeutic procedures. At the same time optical fiber technology has been constantly ameliorated, primarily due to the growth of the telecommunication needs. Thanks to the manufacturing quality and to new types of optical fibers, it is now possible to transport through fibers the high power or energy which is often necessary to achieve therapeutic effects. As these fibers can have a thin diameter, new possibilities of treatment are being offered in that the laser beam can be brought inside the human body through natural openings or small incisions, thereby rendering more invasive procedure unnecessary. In this paper some aspects of power and pulse transportation characteristics of optical fibers are discussed and results of corresponding experiments are shown.
Formation of nonstable color centers in fused silica fibers induced by high-power XeCl laser radiation
Vitali I. Konov, Vladimir P. Pashinin, Alexander S. Silenok
The transmission properties of fused silica fibers irradiated by high power high repetition rate XeC1 laser have been investigated. Laser-induced additional losses of radiation were measured as a function of intensity and of repetition rate.
Flexible cables for IR laser power delivery
Vjacheslav G. Artioushenko, Eugeni M. Dianov, Klaus Doerschel, et al.
Overview of the development in crystalline infrared fibera and hollow waveguides is made for the practical use of the last resialts in applications of the cables based on these fibers and waveguideB.
Fiber optic delivery for excimer laser coronary surgery
Roderick S. Taylor, Kurt E. Leopold
The development of specialized fiber tips, tapered fibers and fiber bundles for the XeCl excimer laser recanalization of coronary arteries during open heart surgery is described.
Comparison of core fibers and contact probes for laser surgery
Rudolf W. Steiner, J. Keckstein M.D., Anthonio Finger
Advanced laser operational techniques have been introduced using the Nd:YAG or the argon laser in combination with fiber techniques and contact probes . In gynaecology, for exantple, surgeons need highly flexible fiber transmission systems for laparoscopic operations 2 Indications such as adhesiolysis or endornetriosis can be treated without mechanical traumatisation and bleeding using the laser light. Laser systems with different wavelengths, fibers and tips have become a very flexible surgical instrument. Feedback control of the reaction of the laser light with tissue makes the inedical laser system save and reliable.
Laser lithotripsy using double pulse technique
Juergen Helfmann, Klaus Doerschel, Gerhard J. Mueller
There are currntly several methods in the field of laser lithotripsy which operate not only at different wavelengths and pulse lengths but also with various types of optical front ends and various irrigation fluids'6. The methods can be divided into two main groups: First, those which utilize stone absorption and plasma formation on the stone surface to initiate stone fragmentation, such as dye lasers. Second, those which generate shock waves and caviatation in the surrounding fluid and which require additional means to produce aplasma (e.g. irrigation, focussing fiber end or metal surfaces). The pulsed Nd:YAG laser belongs to this group. The method presented here is the double pulse technique which is a combination of both methods. It uses two laser pulses with a short time delay transmitted by means of a fiber to destroy body concrements. The first pulse is the first harmonic of the Nd:YAG laser (532nm) which improves the coupling efficiency of the laser radiation with the stone. The second pulse is in the fundamental mode of the laser (1064 nm) delivering the high energy for the stone disruption.
Factors effecting the light distribution of cylindrical diffusers
William R. Potter, Leroy Wood, Earl E. Purcell Jr.
Th space irradiance produced by a fiber with a cylindrical diffusing tip was measured under a variety of launch and mode miling conditions. The aim of these measurements was to determine the extent to which conditions of use would effect the light distribution and to assess the impact these variations in light distribution would have on the therapeutic effect when the fibers were used in Photodynamic therapy treatments.
Uniform light distribution in hollow organs by means of backscattering layers
Wolfgang Beyer, Reinhold Baumgartner, Christian Ell, et al.
The uniform distribution of light over the area to be photodynamically treated is one of the prerequisites for a successful tumor therapy. For homogenization of laser light distributions especially in hollow organs a new method has been developed. It applies fiber coupled emitters in combination with a highly backscattering layer deposited on the inner wall of the organ to be irradiated. The effect of homogenization by means of this layer has been calculated for spherical and cylindrical hollow organs and compared with experimental results. This method also seems to be applicable for organs with irregular geometry. Laser light applications for different medical fields will be described. Applying the same method, isotropic light detectors with diameters of less than 1 mm have been developed for irradiation control during photodynamic treatment or for determination of light distributions in tissue.
Modified fiber tips for light application in hollow organs
Armin Heinze, Wolfgang Beyer, M. Krug, et al.
Four ways of optimizing laser-assisted treatments in hollow organs are proposed in this paper: 1 . For coagulation in axial direction at small irradiation distances fiber tips with enhanced divergence increase the coagulation volume and reduce vaporization. 2. Circumferentially complete coagulation of cylindrical organs can be achieved by using a radially radiating probe. 3. Radiators for photodynamic therapy in cylindrical organs can be constructed and optimized by means of a theoretical scattering model. 4. Isotropic radiators based on conical fiber tips improve the radiation into the rear hemisphere.
Quartz contact probe for use with argon and Nd:YAG lasers
Nicholas J. Razum, Gregory S. Keller M.D., James Glenn Bradley M.D., et al.
Contact fiberoptic surgery has been an important step in the evolution of modern day laser surgical procedures. Synthetic sapphire tips, attached to the end of a surgical fiber, are an accepted modality. Sapphire tips optically mold the distribution of the lasers energy exiting the fiber. New developments in quartz fiberoptic tips have provided surgeons with similar tissue results as sapphire tips, with greater flexibility, decreased size, and reduced cost. A pilot study was conducted at the Western Institute for Laser Treatment utilizing these quartz fibers in research and progressing into clinical procedures. The development was through a laser peripheral company; Laserguide Inc.
Light monitoring by isotropic and by integrated fiber detectors
Ronald Sroka, Reinhold Baumgartner, Wolfgang Beyer, et al.
In the medical field of laser light application detector systems are required for measuring the light power applied to the tissue and monitoring instabilities caused by the delivery system during the application of the laser light. An isotropic detector was developed consisting of a fiber tip molded to a sphere and covered with diffuse backscattering layers. The homogeneity of the isotropic detection is 85-90% in an angular field of Additionally a monitoring device has been developed which consists of a darkened chamber holding a part of the fiber bent to a curve. Integrated photodiodes detect the photons "stepping" out of the fiber. Defects of the fiber, the fiber tip, changes in the medium around the fiber tip, and variations of the laser output have influences on the detector signal. Both devices could be useful in evaluating an exact dosimetry for light.
Optical Fibers and Sensors in Medical Diagnostic
icon_mobile_dropdown
Mode mixing in fiber optic oximeter
Most catheter based oximeters use optical fiber to deliver two M more colors of light to the blood and collect the reflected lights with another optical fiber. Oxygen saturation of the blood is calculated from intensity of the returned lights. The coupling efficiency of this type of two-fiber sensor depends on the separation of fibers, the numerical aperture (NA) of the fibers, and the launching condition of lights from LED's to the transmission fiber. A micro-optical integrator was designed to combine outputs from two LED's into a multimode step-index fiber pig-tail through a high NA microball lens. The mismatch in the modes of propagation between red and IR lights was corrected by looping and sine-wave bending the fiber before it was coupled to an NA limiting GRIN lens, which also serves as an exit window. A far-field scan of two lights shows these two lights have spatial overlap of 92% or better. The overlap at the tip of the catheter, after it was coupled to the mode mixing pig-tail, is better than 98%. The addition of this simple method of mode-mixing has improved the overlap by nearly 30% and has substantially improved the accuracy of the oximeter, especially when in vitro calibration is used before taking the measurement in blood.
Hematocrit independent in-vivo measurement of oxygen saturation and indocyanine green concentration with a CCD array camera
Thomas Schroeder, Rainer Pahl M.D., Jens Peter Hering, et al.
A method was developed to measure 02-saturation and Indocyanine-green concentration without external haematocrit correction by recording reflection spectra with a fiberoptic catheter and a CCD array camera, connected with ap-computer. The calculation is based on evaluation of the whole spectrum. Thereby it was shown that it is possible to determine Indocyanine-green and O2-satrati0n and to correct the haematocrit using three wavelengths instead of two wavelengths as usually done. The calculation differs from conventional methods not only in the additional wavelength, but also in the bandwidths used. When compared with extracorporal photometric transmission reference techniques the correlation coefficients of O2-saturation are r=O.996 (n=67) in vitro and r=O.993 (n=267) in vivo, and the coefficients of Indocyanine-green are r=O.996 (n=87) in vitro and r=O.998 (n=107) in vivo. In comparison with the same reference technique, a conventional commercial fiberoptic reflection photometer (IVH3, Fa. Schwarzer, MUnchen, Germany) using LED's at two wavelengths and requiring haematocrit correction showed somewhat poorer linearity and correlation coefficients. [ Indocyanine-green, in vivo r=O.995 (n=96); 02-saturation, in vivo r=O.976 (n=92) I
Skin erythema meter
Harri K. Kopola, Arto Lahti, Risto A. Myllylae, et al.
The skin erythema meter is a fibre-optic, dual wavelength reflectance meter which measures the reflectance of the skin on two wavelengths, one the blood/haemoglobin absorption band (555 nm) and another a reference (660 nm). The instrument consists of a fibre-optic sensor head, a microprocessor-based control and analysis unit and a plotter, and it presents the relation between the measured reflectance results in terms of a reflectance index (R(555nm):R(660nm)). The measurement cycle, including printing, takes 5 seconds. Stability tests on the erythema meter (constant distance, reference object) showed the standard deviation of the reflectance index to be +/- 0.1%, while that in repeatability tests was <+1- 0.5% for skin and <+1- 0.2% for paper with hand-held positioning and repetition. The dynamic change in the reflectance index was about 30% with strong irritation. Results of various irritation test series on human skin are also presented. Finally, the performance and applicability of the skin erythema meter with respect to allergy test procedures, irritancy testing and measurement of UV-induced erythema are discussed.
Multichannel infrared fiber optic radiometer for controlled microwave heating
S. Drizlikh, Albert Zur, Abraham Katzir
An infrared fiberoptic multichannel radiometer was used for monitoring and controlling the temperature of samples in a microwave heating system. The temperature of water samples was maintained at about 40 °C, with a standard deviation of ± 0.2°C and a maximum deviation of ± 0.5°C. The temperature was monitored on the same time at several points on the surface and inside the sample. This novel controlled system is reliable and precise. Such system would be very useful for medical applications such as hypothermia and hyperthermi a.
Fiber optic sensors based on time-release polymers
Steven M. Barnard, David R. Walt
Fiber-optic sensors based on a controlled-release polymer provide sustained release of indicating reagents over long periods. This technique allows irreversible chemistries to be used in the design of sensors for continuous measurements. The first reported sensor used 8-hydroxypyrene- 1 ,3,6-trisulfonic acid and sulforhodamine 640 to measure pH continuously for three months in the range of 5.5 to 8.0 with a precision units. The sensor reported in this paper is based on a fluorescence energy transfer immunoassay. The sensor was cycled through different concentrations of antigen continuously for 30 hours. Although the sensor was not optimized, the data indicates the viability of the technique.
Stability studies of a pH-sensitive polymer matrix: applications to fiber optic pH sensors
A ratiometric pH-sensitive fluorescent dye (hydroxypyrenetrisulfonic acid) was covalently attached to an acrylamide polymer. These pH-sensitive copolymers were either covalently bonded to the end of an optical fiber or polymerized into separate gels. Long-term, accelerated aging studies were performed on the fibers and gels in 43°C distilled H20. The fiber-immobilized optrodes gave good pH responses for up to 2 months. The pH-sensitive gels were physically attached to optical fibers and gave very good pH responses for over one year. These physically immobilized, one-year-old, pH-sensitive copolymers provided optrodes with linear pH responses between pH 6 and 8 and resolution greater than 0.25 pH unit. A simple photostability experiment on these optrodes showed that they were very photostable. The results of this study indicate that pH-sensitive copolymers in a simple optrode design can be employed as pH sensors with useful lifetimes exceeding one year.
Direct Measurements with Optical Fibers
icon_mobile_dropdown
Fluorescence and Raman spectroscopy of biopolymers subsequent to excimer laser photoablation
Frank M. Cerio, Richard H. Clarke, Jeffrey M. Isner M.D.
The purpose of the fluorescence and Raman experiments in this study is to identify the cause of the red shift in the observed fluorescence emission of coronary arteries after laser ablation. In addition the identity of the molecular bonds broken in the photoablation process has been probed. These identifications are necessary, if one is to understand the laser tissue interaction and to monitor this interaction in a laser angioplasty procedure.
Fiber optic fluorescence detection of low-level porphyrin concentrations in preclinical and clinical studies
Thomas S. Mang, Carolyn McGinnis, S. Khan
A significant clinical problem in the local treatment of cutaneous metastases of breast cancer (by any modality--surgery, radiation therapy or photodynainic therapy) is the fact that the disease almost always extends beyond the boundary of visible lesions in the form of microscopic deposits. These deposits may be distant from the site of visible disease but are often in close proximity to it and are manifested sooner or later by the development of recurrent lesions at the border of the treated area, thus the "marginal miss" in radiation therapy, the "rim recurrence" in photodynamic therapy, and the "incisional recurrence" following surgical excision. More intelligent use of these treatment modalities demands the ability to detect microscopic deposits of tumor cells using non-invasive methodology. In vivo fluorescence measurements have been made possible by the development of an extremely sensitive fiber optic in vivo fluorescence photometer. The instrument has been used to verify that fluorescence correlated with injected porphyrin levels in various tissues. The delivery of light to excite and detect background fluorescence as well as photosensitizer fluorescence in tissues has been accomplished using two HeNe lasers emitting at 632.8 nm and 612 nm delivered through a single quartz fiber optic. Chopping at different frequencies, contributions of fluorescence may be separated. Fluorescence is picked up via a 400 micron quartz fiber optic positioned appropriately near the target tissue. Validation of these levels was made by extraction of the drug from the tissues with resultant quantitation. Recently, an extensive study was undertaken to determine if fluorescence could be used for the detection of occult, clinically non-palpable metastases in the lymph node of rats. This unique model allowed for the detection of micrometastases in lymph nodes using very low injected doses of the photosensitizer Photofrin II. Data obtained revealed the ability to detect on the order of 50-100 cells using 0.25 mg/kg of sensitizer, a level 20 times lower than normally used for treatment of animal tumors. These results indicate that Photofrin II could be used for fluorescence detection of small metastatic tumors, while substantially reducing the major side effect of PDT; namely, prolonged photosensitivity. Results to be presented demonstrate the ability of this technique to detect microscopic deposits of malignant tumor cells in patients with metastatic breast cancer. These deposits were found in clinically negative areas of the chest wall.
Fluorescence fiber optic probe with distance correction for endoscopic use
Paul M. Paspa, A. Charles Lytle, J. Brian Dunn, et al.
The introduction of fiber optics together with lasers has opened up many new areas of medicine, and in the case of the Fluorescent Fiber Optic Probe (hereafter Probe) make it possible to more selectively detect photosensitive drugs bound in tissue. In this case the fluorescent marker was formerly hematoporphyrin derivative (HpD), and has recently been inrnroved and replaced by dihemnatoporphyrin ether/ester (DHE) . ornmercially the drug is available under the trade name of Photofrin II Due to the small and flexible nature of the fibers themselves, fiber optics are an ideal tool to deliver and detect light through the biopsy channel of many commonly used endoscopes. In the case of the Probe a krypton laser operating in the violet region of the visible spectrum (406. 7 (36%) , 413 . 1(60%) , 415. 4 (4%)nm) is used as the exciting source to take advantage of the strong absorption peak of DHE around 410 nm. By monitoring the level of tissue autofluorescence (570 nm) and DHE fluorescence (690 nm) we are able to provide an output to indicate those areas where the fluorescent marker drug is localized while correcting for large variations in the fluorescence signal due to distance changes. Distance variations of the detecting fiber from the source are corrected for by ratioing the level of the two individual fluorescent signals received to provide a relatively linear fluorescent output reading with respect to individual channel readings and distance. The Probe is also designed to detect fluorescent drugs bound in tissue while working in the presence of the white light source used in endoscopy. The probe together with its own exciting light source (krypton laser) works as a stand alone device and does not require any modification or interlock with existing endoscopic equipment. Only the use of the biopsy channels of the endoscope are needed to insert the optical pick-up and delivery fibers.
Fiber optic laser light scattering measurement of ciliary function of the fallopian tube
Sheridan A. Halbert, Kap Lim, Wylie I. Lee
A fiber-optic laser light-scattering system (FLS) for measuring ciliary function was evaluated by means of three sets of in vitro experiments. First, FLS performance was compared to that of a previously proven benchtop laser system (BLS). Using tissue excised from rabbit fallopian tubes, ciliary beat frequency (CBF) of each sample was measured with FLS and BLS. Paired CBF measurements showed excellent correlation between the two systems (r =0.93). Second, the FLS was used to evaluate the dependency of CBF on temperature (T) by using tissue sampies of rabbit oviductal fimbna. Regression analysis of CBF vs T showed a linear relationship over the range of 18-37°C for both individual samples (r =0.98) and pooled data from all experiments (r = 0.84). Fmally, the relalionship between CBF and ciliary ovum transport rate (TR) was tested by using T to modulate CBF of rabbit fimbria, in vitro. The relationship was linear over the range of CBF from 10 to 30 Hz (r2 = 0.83). At 37°C, CBF = 31±1 Hz, and TR = O.12±.02 mm/sec. equal to ovum transport rate in situ. The FLS is a valuable tool for characterizing ciliary activity and thus ovum transport function. Owing to the fact that ciliary dyskinesia resulting from disease of the fallopian tube is associated with infeitility, the FLS may be useful to acquire data important to the clinical evaluation of fallopian tube function and female infertility.
Fiber optic radiation dosimetry for medical applications
Harald Bueker, Friedrich Wolfgang Haesing, S. Nicolai, et al.
The dosimetry with glass fibers perrilits for the first time the dose to be determined in the immediate vicinity of the tumour. A fiberoptic dosimeter can either be introduced during an operation or else inserted via a cannula into the vicinity of the tumour to be irradiated. The dosimeter should remain in the patient's body until radiation therapy has been completed. The basic principle of the fiberoptic dosimeter is to measure the additional attenuation generated in the fiber by irradiation. A lead-glass fiber with 60 weight - % PbO was used as a particular radiationsensitive fiber. This is a step-index fiber with a core diameter of 100 pm and a total diameter of 110 pm. Measurements of the spectral distribution of the induced loss result in a detection sensitivity of smaller than 0.1 Gy for the lead-glass fiber at a local resolution of about 2 cm. This satisfies the demands of radiotherapy.
Infrared fiber optic radiometry analysis to prevent tissue injuries during endourological laser therapy
Yuichiro Daidoh M.D., Tsunenori Arai, Satoshi Inazaki, et al.
To prevent a false laser irradiation to an urotherial tissue during the laser stone fragmentation, we applied the fiber-optic pulsed photothermal radiometry (PPTR) to discrimination between urinary stones and urotherial tissues. The experiment was made in vitro with the various wet sample of the urinary stones and the canine urotherial tissues. Three different lasers, ultraviolet argon laser(UV Ar laser), visible argon laser(Vis. Ar laser) and carbon monoxide laser(CO laser), were used for excitation light sources of the PF'TR method and compared to obtain clear discrimination between the stones and the tissue. The UV Ar laser gave the best result among them. The wet canine urotherial tissue was clearly differential from the urinary stones by the measurement of the e-folding decay time of the PPTR waveform.
Raman Applications in Fiber Diagnostics
icon_mobile_dropdown
Prospect of utilizing surface-enhanced Raman spectroscopy for bio- and biomedical sensing
Michael M. Carrabba, Lois S. Robblee, R. David Rauh
This paper will evaluate the potential applications of SERS for bio- and biomedical sensing. The emphasis willbe on technologies which will allow the development ofcost effective SERS instrumentation. Potential techniques which can be adapted to fiber optic based sensing will also be discussed.
Surface-enhanced Raman probes of neurotransmitters
Michael D. Morris, Michael L. McGlashen, Kevin L. Davis
SERS of catecholamines and histamines is discussed. The SERS of histamines is partially assigned. The use of cellulose acetate electrodes for SERS in matrices with a high protein burden is described.
Optical fiber sensor for oxygen with Raman scattering sampling
Dexiu Shi, Myron Lee Wolbarsht
The Resonance Raman spectra of hemoglobin (Hb) molecules are exclusively due to scattering of the heme group, and the spectrum of a partially oxygenated Hb sample can be employed as a measure of oxygen partial pressure. A optical fiber oxygen sensor based on immobilized Hb is proposed by taking advantage of the Resonance Raman spectra of oxyHb and deoxyHb.
Development of a drug assay using surface-enhanced Raman spectroscopy
S. Michael Angel, Jeffrey N. Roe, Brian D. Andresen, et al.
Surface-enhanced Raman spectroscopy has been used to detect low levels of several chemical compounds, including the drugs of abuse -cocaine hydrochloride and methamphetamme hydrochloride. Raman spectra of these substances have also been taken over optical fibers using red-wavelength excitation. These measurements demonstrate the feasibility of the remote determination of various target chemicals using diode laser excitation and diode array detection.
Diagnostic Systems II
icon_mobile_dropdown
Compact fiber optic sensor for in-vivo enterogastric reflux detection
Riccardo Falciai, Francesco Baldini, Paolo Bechi, et al.
The characteristics of an optical fiber sensor for the entero-gastric reflux are described. Two different probes are developed for "in vivo" measurements making use of PCS fibers (200 um core diameter) and of a fiber bundle respectively. The performance of the sensor and of the two probes are discussed and experimental "in vivo" results are reported.
Fiber optic intracranial pressure sensor system
Jan Dorosz, Krzysztof Kruczkowski
Fiber optics, thanks to its many advantages finds new areas of ap plication in medicine. This paper describes a fiber optic pressure sensor system. A short sensor theory, a building of a sensor probe and a callibration during measure methode are given.
Catheter-Based Medical Diagnostics and Imaging
icon_mobile_dropdown
Intravascular ultrasonic characterization of coronary structure
Peter J. Fitzgerald
Ultrasonic intravascular imaging is a rapidly developing technology that permits unique visualization of the inner architecture of peripheral and coronary vessels. A number of groups have published limited trials using these devices directed at assessing their safety and ability to accurately represent endovascular detail. The challenge that lies ahead is to prove that this technology is useful clinically for the diagnosis and treatment of vascular disease. The potential clinical utilities that appear realistic include; (i) quantitating the degree of vascular stenosis, (ii) guiding interventional therapies, and (iii) tissue characterization of atheromatous plaques. Although preliminary results are encouraging in each of these categories, additional work is needed to determine what clinical impact this imaging modality will have in vascular disease.
3-D visualization of arterial structures: tissue differentiation techniques
Richard I. Kitney, Christopher J. Burrell M.D., Lincoln Moura, et al.
We have previously described a method for the 3-D visualisation of arterial structures using the voxel space approach to three-dimensional solid modelling. The system we use for intra-arterial imaging, in vitro and in vivo, is based on ultrasonic data, acquired with a purpose-built, catheter-mounted ultrasound probe. In this paper, we describe the methods employed for the reconstruction of 3-D models from these 2-D ultrasonic data and present preliminary work on tissue differentiation, using arterial models and colour-coding of the image.
Angioplasty under ultrasound?
Christopher J. Burrell M.D., Richard I. Kitney, Keith Straughan, et al.
In this paper, we discuss some of the problems associated with attempting to image blood vessels using ultrasound from an intravascular approach. These include device miniaturisation, ultrasonic problems, difficulties with positioning and orientation of the device, and problems associated specifically with imaging catheters incorporating mechanically rotating parts. Some of the possible solutions are suggested, in terms of modification of transducer design, which may ultimately allow us to realise the goal of directing intraluminal treatment devices by means of intravascular, ultrasonic imaging.
Potential of intraluminal ultrasound for angioplasty guidance
Marwan R. Tabbara, George E. Kopchok M.D., Rodney A. White M.D.
The manifestation of atherosclerotic lesions in arteries can vary from asymptomatic thickening in the vessel wall to complete occlusion. Experimental studies on non-human primates and on human subjects indicate that atherosclerotic lesions may progress without a reduction in luminal diameter because of dilatation of the arterial wall . Although angiography has been considered the "gold standard" for visualization of the arterial tree ar1 detection of luminal narrowing, it does not demonstrate arterial wall thickening or morphology. Moreover, the measurement of luminal diameter of the sane lesion can vary considerably depending on the plane of projection of the x-ray beam. This is attributed to the eccentric nature of the residual lumen in an atherosclerotic vessel . Extraluminal B-mode real time imaging has the feasibility of demonstrating arterial lumen and arterial wall thickness. However, it is still in some instances limited by inadequate resolution and image quality. Intraluminal ultrasound using a phased array or rotating transducer gives better definition of the vessel wall and luminal diameter as it is not limited by the tissue interposed between the vessel and the probe in transcutaneous devices. This paper demonstrates further experience with intravascular ultrasound as a diagnostic tool using B-mode real time imaging.
Engineering considerations for integrating laser angioplasty with ultrasound diagnostics in a single device
James D. Passafaro, Paul J. Zalesky
The application of direct laser energy for the ablation of atherosclerotic plaque has been investigated extensively. It has been recognized that the need for an onboard guidance capability which can direct the laser energy is essential for controlled plaque removal. Intravascular ultrasound represents one approach for identifying diseased tissue and directing laser therapy. The design of a catheter with combined laser and ultrasound capabilities is discussed. The design considers the optical and acoustical requirements. In addition, vascular anatomical constraints and their impact on the mechanical aspects of the device configuration are considered. The optical considerations dictate safe and predictable high energy laser transmission. The acoustic requirements consider material properties and ultrasonic beam resolution. The vascular anatomy imposes constraints on maximum catheter size and it requires a means for conventional delivery of the device to the targeted lesion.
Fiber optic holographic endoscopy
The combination of holographic metrology with endoscopic imaging allows the development of a new class of minute instruments for high-resolving, noncontactive, non-destructive quantitative diagnostics within body cavities. This includes the analysis of structure, form, deformation and vibration of the object under study. There are two possibilities of holographic endoscopic recording: at the distal end within the instrument or with an external holographic camera. In both cases optical fibers are essential for easy handling and flexibility of the holographic endoscopic system. Avantages and drawbacks of optical fiber use are discussed and examples of medical applications are presented.
Spectroscopic Imaging
icon_mobile_dropdown
Optimum illumination wavelength for fluorescence spectroscopy of atheromatous plaque
Arthur F. Gmitro, Andrew L. Alexander, Carolyn M.C. Davenport, et al.
Seven illumination wavelengths from 270 to 364 nm were investigated for their ability to produce differences in the fluorescence spectra between normal aorta and atheromatous plaque. Differences in the spectra were evaluated using the Hotelling trace and ROC methods. The results indicate that large spectral differences and, therefore, good classification can be obtained with illumination in the range from about 304 to 334 nm and that the performance drops off rapidly on either end of the illumination range.
Endoscopic optical metrology: the possibilities of holographic interferometry
Of the various holographic measuring methods, holographic interferometry has found the broadest application in biological and medical research. It allows for non-destructive evaluation and for high resolution deformation analysis. By combining holographic interferometry with endoscopic imaging it is possible to obtain holographic imaging inside natural cavities of the body , thus making possible intracavitary measurements of size, shape or deformation of the objects under study. Some applications of holographic interferometry with endoscopic imaging are reviewed in this paper.
Detection of lung cancer by ratio fluorometry with and without Photofrin II
Stephen Lam, Jaclyn Hung, Branko Palcic
Fluorescence bronchoscopy with a ratio fluorometer probe was used to examine patients with known or suspected bronchogenic carcinoma to determine if early lung cancer can be detected with low dose Photofrin II without skin photosensitivity. Seventeen patients were examined 24 hours after injection of 0.25 mg/kg Photofrin II. Using a red-green (R/G) ratio of greater than 1.5 times the mean value of normal areas as being potentially significant, both carcinoma in situ and invasive cancers were accurately localized (sensitivity 100%, specificity 61%). The majority of the false positive fluorescence (80%) came from the lesions with dysplasia. The elevated R/G ratios from the cancerous and pre-cancerous lesions were found to be due to a significantly lower green autofluorescence. No skin photosensitivity was observed on all seventeen patients. Ratio fluorometry was also carried out in thirty-one patients with known or suspected lung cancer without Photofrin II. A similar diagnostic accuracy was found (sensitivity 90%, specificity 86%). Our results suggest that early lung cancer may be detectable by ratio fluorometry by exploiting autofluorescence differences between tumor and normal tissues.
Monitoring neonatal bilirubinemia using an optical patch
Hyperbiirubinemia is a serious condition affecting many neonates, andthere is a clinical need to monitor the bilirubin levels in susceptible infants. Transcutaneous bilirubinometry by means of an optical patch taped onto the skin would offer an inexpensive, non-invasive method to measure the bilirubin levels in infants. Such a system should give reliable bilirubin readings invariant with the melanin pigmentation, water content, and condition of the skin. We have determined the optical properties of neonatal skin. We are using these optical properties to create scaled phantom models of the skin, and to conduct Monte Carlo computer simulations of light propagation in skin. These models are being used to study how reflectance spectroscopy is affected by the spatial distribution of absorbing chromophores in the skin, and by the wavelength dependence of light collection.
Fiber Optic Imaging
icon_mobile_dropdown
Technical considerations for angioscopic imaging
Brett A. Trauthen
An angioscopic imaging system involves several interfaces among its optical and mechanical components. For best results, the system should be optimized at least to the level of its weakest link. As with any multi-component system, the process of optimizing an angioscope system begins with careful analysis of the functional properties of each component followed by a design study to determine how the components work together. The component technology has evolved to provide sufficient image quality so that the physician-user can use the information for diagnostic applications.
Percutaneous coronary angioscopy with a new steerable microangioscope: experimental and early clinical results
Stephen R. Ramee M.D., Christopher J. White M.D., Juan E. Mesa M.D., et al.
We have developed a new, steerable microangioscope for performing percutaneous coronary angioscopy. The angioscopic catheter is made of polyethylene, contains a distal balloon for occlusion of blood flow during imaging, fits through an 8 Fr percutaneous coronary angioplasty (PTCA) guiding catheter and is steerable by means of a guidewire. Initial feasibility was demonstrated in animal studies involving both peripheral and coronary arteries. Angioscopic findings in normal vessels included normal endothelial surface, collateral blood flow, and side branches. Angioscopy was also performed after balloon denudation of the arteries, laser- assisted balloon angioplasty, and stent implantation. In early human clinical trials we have performed percutaneous angioscopy in six patients undergoing percutaneous coronary angioplasty without complications. Findings in these patients include atherosclerotic plaque, thrombus, and dissection. This new device has great potential for use in the research, diagnosis, and treatment of coronary atherosclerosis.
Novel Techniques
icon_mobile_dropdown
3-D blood flow visualization
Richard I. Kitney, Christopher J. Burrell M.D., Don P. Giddens, et al.
In this paper, we show how 3-D arterial visualisations may be combined with a 3-D representation of blood flow. We have developed techniques for the estimation and representation of the entire 3-D flow field for the section of artery under investigation. The flow fields are calculated from numerical solutions of the Navier-Stokes equations by a flow solver using a finite difference approach. In order to achieve this, both the profile of the inlet velocity waveform and the shape of the external grid structure of the flow field, derived from the 3-D solid model, are required. Clinically useful 3-D flow information is presented effectively by using a combination of 2-D cross-sectional displays.
Performance and applications of the dynamic focus scanning laser imaging system
Bradley D. Clymer, Jogikal M. Jagadeesh, Gregory S. Bergmann, et al.
A multipurpose digital imaging device has been developed for applications in quantitative densitometry, light scatter detection and fluorescence emission measurement. The Scanning Laser Imaging (SLI) device consists of a three-dimensional laser beam controller, a fiber optic faceplate coupler, a specially designed photodetector assembly and a support computer that has interactive control over the beam positioner. Image information is collected as measurement of either total forward light loss, forward direction scattering or fluorescent emission, depending on the nature of the biological target and the configuration of the detection assembly. Signal output from the bulk photodetector is digitized and assigned to the corresponding pixel location illuminated by the laser spot. The target and detector assembly are stationary while the laser spot is scanned in a programmed pattern. Areas up to 16 cm2 are scanned at a rate of 5.1 x iO pixels/s with 12 bits gray level detection range per pixel. Typically, 1024 x 1024 pixels are captured in less than 30 seconds and stored for display, processing or archiving. Spatial resolution for image reconstruction is a function of laser spot size and has been demonstrated to 3 pm. Rescan and arbitrary laser spot positioning is accomplished to within Biological, biophysical, clinical instrumentation and optical and computer engineering applications of this technology are broad. SLI methods have been developed for quantitative densitometric analysis of electrophoretic gels, thin-layer chromatography plates and autoradiographic materials generally used in molecular biology research. These applications are not well suited for conventional scanning densitometry, particularly when translucent materials such as nylon or nitrocellulose transfer membranes are used because of loss in resolution due to scattering. The SLI spatial resolution is not affected significantly by such scatter. Other quantitative analysis such as measurement of immunofluorescent and immunochemical staining of cells from blood samples and tissue sections can be performed with the SLI device. These applications are poorly suited for traditional flow cytometry, which requires dispersal of individual cells from the tissue. In addition to imaging, the SLI device is capable of detecting and analyzing the occurrence of very rare events. It is routinely capable of scanning a large transparent or translucent target, detecting submicron particles and recording the position of the particles to within approximately 1 pm. The system will detect and locate a single submicron particle placed anywhere on a 800 mm2 surface, a task analogous to locating a standard typewritten character placed on a football field, within 30 seconds.
Laserthermia and New PDT
icon_mobile_dropdown
Pathological studies using laserthermia with Nd:YAG laser
Naoto Mamiya, Hiroshi Tsunekawa M.D., M. Sugihara M.D., et al.
In 198k we developed a method of hyperthermia using Nd:YAG laser (laser thermia) a system for transmitting continuous low power energy (2 W) through an artificial sapphire interstitial probe for local hyperthermia (43-0.5°C). Our experimental and clinical evidence indicated that this method is safe and effective. The process of tumor destruction induced by laser thermia is, however, poorly understood. We performed in vivo histopathological studies and obtained the following results; 1) At the tissue level, the initial change after laser thermia was the damage of tumor feeding vessels. 2) At the cell level, immediately after laser thermia the mitochondria in the intracellular organella were completely destroyed.
Development of hybrid laserthermia probe for single-channel G1 endoscope
Sotaro Suzuki, Hiroyuki Narumi, Jun Aoki M.D., et al.
The computer controlled Laserthermia system by the method of using double channel endoscope with the contact frosted probe and a thermocouple was reported previously.25 In this paper, the single channel method with the new single laser delivery system was studied experimentally. Especially hyperthermal effect by the newly developed Hybrid Laserthermia feedback probe(Hybrid probe) was discussed comparatively with the effects by the interstitial contact probe. The Hybrid probe could be possible to treat clinically more accurate Laserthermia in the near future.
Some attempts for improvement of balloon laserthermia
Koichi Futatsuki, Koji Saifuku, Kunio Yamamoto, et al.
We investigated the use of a new Nd:YAG laser irradiation method, 'balloon laserthermia' I involving use of a balloon filled with a light diffusing substance attached to the end of a quartz fiber. This balloon laserthermia technique, using a 3cm diameter balloon containing 0.25% Intralipid solution, was tested on a Meth-A sarcoma in Balb-C mice. A 20 minute irradiation at 20 watts resulted in the following necrosis rates: control group -4%; 40.0-40.5°C. 35%; 42.5-62%; 50.0 -50.5°C. - 97%. When the balloon size was reduced from 3 to 2cm, the optimum values for hypertherinia were a 0.5% Intralipid solution density and a laser power output of 10 watts. As previous use of balloon laserthermia has generally involved use of quartz fibers with a standard 8° angle of light emission, these experiments included trials of a fiber with a 40°light emission angle, along with various combinations of solution densities and laser output conditions. When used with 0.25% Intralipid I the wide-angle fiber provided a power density distribution around the balloon equivalent to that of the standard fiber, but with only half the laser output for hyperthermia, about 10 watts.
Laserthermia for the treatment of small hepatocellular carcinoma: a preliminary study
Teh-Hong Wang, Guan-Tarn Huang, Jin-Chuan Sheu, et al.
A new designed interstitial probe (hybrid probe) was used to treat small hepatocellular carcinoma(HCC) with laserthermia. Before the human study, testing in normal rabbit liver was done to measure the thermal map. And then laserthermia was studied in human small HCC. The set condition was 43-45° C in thermocouple and the duration of laserthermia was 20 minutes. From the follow-up computed tomography and liver biopsies, laserthermia had tumorcidal effect. It is concluded that laserthermia may be helpful to the patients with small HCC.
Laserthermia for deep-seated brain tumors using a hybrid laserthermia probe
Hideru Sato, Tsuneo Sakai M.D., Ichiro Fujishima M.D., et al.
A new laserthermia system using Nd:YAG laser with a hybrid laserthermia probe was developed to overcome a certaine disadvantage of conventional laserthermia system with a frosted tipped cantact probe. Experimental and clinical studies ravealed that laserthermia system using a hybrid laserthermia probe was effective, easy, and safe to treat deep seated brain tumors.
Optimal temperature control in laser hyperthermia
Douglas Robert Wyman, Carrie-Lynne Swift, Rosemarie A. Siwek, et al.
Interstitial laser hypefthezmia is a tecbnique for the treatment of malignant tumors that involves heating a tumor volume by directing infrared laser light, usually from an Nd: YZG laser, into the volume through interstitially iirlanted optical fibers . We have developed a multi-source, multi-sensor corruter controlled laser hyperthermia system similar to that first described by Daikuzono et al .' In this system, irrlanted inicrothermocouple sensors provide internal terrerature feedback to an algorithm that dynamically deteimines how much light should be directed into the various optical fiber sources, in order to maintain a spatially and tenporally unifoirn teriperature distribution in a tumor volume. This algorithm allows for the tissue thermal response to light to change over time (nonlinear system) , for exarrle, as tissue terterature increases or as tissue damage is incurred. The algorithm eiiploys an original nonlinear system control method that involves a periodic and indirect determination of how each microthermocouple responds to a unit irrulse of light directed down each fiber. Initial testing of the system in a ground beef phantom is described. By accommodating a nonlinear system, our irrlementation of laser hyperthermia should allow for optimal teirerature control.
Diagnostic Systems II
icon_mobile_dropdown
Computerized diode laser system for CO content investigation in human expiration
Andrian I. Kouznetsov, A. P. Logachev, Eugene V. Stepanov
First results of diode laser spectroscopy methods applications for diagnosing the gas content of expired air are presented. Carbon monoxide (CO) contents of expirations of a sportsman and a smoker were subjected to analysis by using a computerized diode laser system. In the first case there was detected a considerable growth of CO concentration after an intensive exercise. In the second one there were revealed and measured three time constants - characteristics of CO removal from the organism. Promising trends of development and applications of diode laser spectroscopy in medicine are at issue.
Raman Applications in Fiber Diagnostics
icon_mobile_dropdown
Surface-enhanced Raman spectroscopy of peptides
Robin L. Garrell, Tonya M. Herne, Angela M. Ahern, et al.
Surface-enhanced Raman (SER) spectroscopy has been used to probe the adsorption, surface interactions, and orientations of peptides on metal surfaces. Amino acids in homodipeptides give SER spectra with unique features that can be used to characterize the surface interactions of specific functional groups in more complicated peptides. In heterodipeptides, there is a hierarchy of functional group-surface interactions that prescribe their orientation and conformation on metal surfaces. By establishing this hierarchy, it is now possible to predict the interactions that occur between larger peptides and surfaces. Furthermore, the observed trends suggest that it should be possible to control these interactions by varying the solution pH, the charge on the surface, and other parameters of the measurement in order to adsorb species selectively from mixtures of peptides in solution. Potential biomedical applications of this technique will be described.