X-Ray Thin Foil Filters At Cryogenic Temperatures
Author(s): Ritva A. M. Keski-Kuha
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

The X-ray spectrometer (XRS), which is being developed for one of the focal plane instruments of the Advanced X-ray Astrophysics Facility (AXAF), requires filters with high X-ray transmittance, high background rejection, and operation at cryogenic temperatures. Thin foil filters can provide high X-ray transmittance and the required rejection for low energy radiation. The results of the test program demonstrate that these filters are fully successful at cryogenic temperatures and therefore can provide blocking filters for the XRS with the required performance.

Paper Details

Date Published: 28 July 1989
PDF: 9 pages
Proc. SPIE 1160, X-Ray/EUV Optics for Astronomy and Microscopy, (28 July 1989); doi: 10.1117/12.962629
Show Author Affiliations
Ritva A. M. Keski-Kuha, NASA/Goddard Space Flight Center (United States)


Published in SPIE Proceedings Vol. 1160:
X-Ray/EUV Optics for Astronomy and Microscopy
Richard B. Hoover, Editor(s)

© SPIE. Terms of Use