
Proceedings Paper
Near-field radio-frequency thermo-acoustic imaging based on transmission lines for optimized performanceFormat | Member Price | Non-Member Price |
---|---|---|
$17.00 | $21.00 |
Paper Abstract
Near-field Radio-frequency Thermoacoustic Imaging (NRTI) is an imaging modality that was recently introduced to
generate thermoacoustic signals using ultra-short high energy impulses. Because it allows for a higher energy coupling
within an ultra-short time, it can achieve higher resolutions and higher signal to noise ratio, compared to traditional
thermoacoustic tomography based on radiating sources at single frequencies. As for traditional thermoacoustic imaging
the contrast comes from the conductivity and the dielectric properties of the tissues, while the resolution depends on the
measured acoustic waves. Since NRTI depends on the efficient generation of high energy short impulses, the ability to
control their time width and pulse shape is of high importance. We present here a methodology for generating such
impulses based on transmission lines. The ability of such generators to generate impulses in the range of tens of nanoseconds
enables high resolution images in the range of tens of microns to hundreds of microns without compromising the
amount of the energy coupled. Finally the pulser is used to generate high resolution images of small absorbing insertions,
of phantoms with different conductivities and of ex-vivo mouse images. From the phantoms it is possible to see both the
capabilities of the system to accurately image small insertions as well as the high quality images generated from imaging
phantoms, from ex-vivo mouse images it is possible to see several anatomical characteristics, such as the mouse
boundary, the spine and some other characteristics in the mouse abdomens.
Paper Details
Date Published: 23 February 2012
PDF: 5 pages
Proc. SPIE 8223, Photons Plus Ultrasound: Imaging and Sensing 2012, 82231O (23 February 2012); doi: 10.1117/12.908616
Published in SPIE Proceedings Vol. 8223:
Photons Plus Ultrasound: Imaging and Sensing 2012
Alexander A. Oraevsky; Lihong V. Wang, Editor(s)
PDF: 5 pages
Proc. SPIE 8223, Photons Plus Ultrasound: Imaging and Sensing 2012, 82231O (23 February 2012); doi: 10.1117/12.908616
Show Author Affiliations
Murad Omar, Technical Univ. Munich (Germany)
Helmholtz Zentrum Munich (Germany)
Stephan Kellnberger, Technical Univ. Munich (Germany)
Helmholtz Zentrum Munich (Germany)
George Sergiadis, Aristotle Univ. of Thessaloniki (Greece)
Helmholtz Zentrum Munich (Germany)
Stephan Kellnberger, Technical Univ. Munich (Germany)
Helmholtz Zentrum Munich (Germany)
George Sergiadis, Aristotle Univ. of Thessaloniki (Greece)
Daniel Razansky, Technical Univ. Munich (Germany)
Helmholtz Zentrum Munich (Germany)
Vasilis Ntziachristos, Technical Univ. Munich (Germany)
Helmholtz Zentrum Munich (Germany)
Helmholtz Zentrum Munich (Germany)
Vasilis Ntziachristos, Technical Univ. Munich (Germany)
Helmholtz Zentrum Munich (Germany)
Published in SPIE Proceedings Vol. 8223:
Photons Plus Ultrasound: Imaging and Sensing 2012
Alexander A. Oraevsky; Lihong V. Wang, Editor(s)
© SPIE. Terms of Use
