Bone cartilage imaging with x-ray interferometry using a practical x-ray tube
Author(s): Kazuhiro Kido; Chiho Makifuchi; Junko Kiyohara; Tsukasa Itou; Chika Honda; Atsushi Momose
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

The purpose of this study was to design an X-ray Talbot-Lau interferometer for the imaging of bone cartilage using a practical X-ray tube and to develop that imaging system for clinical use. Wave-optics simulation was performed to design the interferometer with a practical X-ray tube, a source grating, two X-ray gratings, and an X-ray detector. An imaging system was created based on the results of the simulation. The specifications were as follows: the focal spot size was 0.3 mm of an X-ray tube with a tungsten anode (Toshiba, Tokyo, Japan). The tube voltage was set at 40 kVp with an additive aluminum filter, and the mean energy was 31 keV. The pixel size of the X-ray detector, a Condor 486 (Fairchild Imaging, California, USA), was 15 μm. The second grating was a Ronchi-type grating whose pitch was 5.3 μm. Imaging performance of the system was examined with X-ray doses of 0.5, 3 and 9 mGy so that the bone cartilage of a chicken wing was clearly depicted with X-ray doses of 3 and 9 mGy. This was consistent with the simulation's predictions. The results suggest that X-ray Talbot-Lau interferometry would be a promising tool in detecting soft tissues in the human body such as bone cartilage for the X-ray image diagnosis of rheumatoid arthritis. Further optimization of the system will follow to reduce the X-ray dose for clinical use.

Paper Details

Date Published: 23 March 2010
PDF: 9 pages
Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 76224O (23 March 2010); doi: 10.1117/12.843655
Show Author Affiliations
Kazuhiro Kido, Konica Minolta Medical & Graphic, Inc. (Japan)
Chiho Makifuchi, Konica Minolta Medical & Graphic, Inc. (Japan)
Junko Kiyohara, Konica Minolta Medical & Graphic, Inc. (Japan)
Tsukasa Itou, Konica Minolta Medical & Graphic, Inc. (Japan)
Chika Honda, Konica Minolta Medical & Graphic, Inc. (Japan)
Atsushi Momose, The Univ. of Tokyo (Japan)


Published in SPIE Proceedings Vol. 7622:
Medical Imaging 2010: Physics of Medical Imaging
Ehsan Samei; Norbert J. Pelc, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray