Low dose applications of lightspeed VCT in cardiac imaging
Author(s): Jianying Li; Jiang Hsieh; Ronald Lundgren; Yun Shen
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

We introduced and evaluated the techniques LightSpeed VCT uses to reduce X-ray dose and image noise in cardiac helical CT applications. These techniques include the use of much improved VCT data acquisition system (VDAS) with reduced electronic noise; cardiac bowtie that redistributes X-rays to have more signals for heart and much less flux to the peripheries; adaptive post-processing filters to reduce cardiac image noise; and ECG modulated tube currents to concentrate X-ray dose for desired cardiac phases. Phantom and patient scans were used to evaluate the dose saving and noise reduction potentials of these techniques. The results demonstrated that the improved VDAS reduced image noise 15-20% for cardiac imaging. With same scan technique, the use of cardiac bowtie reduced about 10% dose in terms of CTDIw measurement and clinical evaluation demonstrated additional 7% image noise reduction and equivalent image quality with cardiac bowtie vs. regular body bowtie. The adaptive filter generated 15-20% noise reduction while maintaining image resolution and artery sharpness. Finally, the use of ECG modulated mA method provided up to 50% dose reduction based on CTDIw measurements, but the saving potentials depended on the heart rate and cardiac phase selection. For heart rate of 60bpm and ±15% cardiac phase margin, the average dose reduction could be 30%. Since these dose and noise reduction methods are inclusive and can be combined to produce even greater dose/noise reduction. It is reasonable to believe that with VCT we maybe able to acquire cardiac helical CT images with only 30-40% of the dose of older generation 16-slice CT scanners with similar noise level and same slice thickness.

Paper Details

Date Published: 14 March 2007
PDF: 7 pages
Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 65102B (14 March 2007); doi: 10.1117/12.708384
Show Author Affiliations
Jianying Li, GE Healthcare China (China)
Jiang Hsieh, GE Healthcare Technologies (United States)
Ronald Lundgren, GE Healthcare Technologies (United States)
Yun Shen, GE Healthcare China (China)


Published in SPIE Proceedings Vol. 6510:
Medical Imaging 2007: Physics of Medical Imaging
Jiang Hsieh; Michael J. Flynn, Editor(s)

© SPIE. Terms of Use
Back to Top