Calibration of projection parameters in the varioscope AR, a head-mounted display for augmented-reality visualization in image-guided therapyFormat | Member Price | Non-Member Price |
---|---|---|
$17.00 | $21.00 |
Paper Abstract
Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the real-world scene and the computer generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost- effective head-mounted operating microscope, for AR. In this work, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of sixteen calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24+/- 0.38 pixels or 0.12+/- 0.05 mm for a 640 x 480 display. Maximum error accounted for 3.33+/- 1.04 pixels or 0.33+/- 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.
Paper Details
Date Published: 28 May 2001
PDF: 10 pages
Proc. SPIE 4319, Medical Imaging 2001: Visualization, Display, and Image-Guided Procedures, (28 May 2001); doi: 10.1117/12.428089
Published in SPIE Proceedings Vol. 4319:
Medical Imaging 2001: Visualization, Display, and Image-Guided Procedures
Seong Ki Mun, Editor(s)
PDF: 10 pages
Proc. SPIE 4319, Medical Imaging 2001: Visualization, Display, and Image-Guided Procedures, (28 May 2001); doi: 10.1117/12.428089
Show Author Affiliations
Wolfgang Birkfellner, Univ. of Vienna General Hospital (Switzerland)
Michael Figl, Univ. of Vienna General Hospital (Austria)
Klaus Huber, Univ. of Vienna General Hospital (Austria)
Johann Hummel, Univ. of Vienna General Hospital (Austria)
Rudolf A. Hanel, Univ. of Vienna General Hospital (Austria)
Michael Figl, Univ. of Vienna General Hospital (Austria)
Klaus Huber, Univ. of Vienna General Hospital (Austria)
Johann Hummel, Univ. of Vienna General Hospital (Austria)
Rudolf A. Hanel, Univ. of Vienna General Hospital (Austria)
Peter Homolka, Univ. of Vienna General Hospital (Austria)
Franz Watzinger, Univ. of Vienna General Hospital (Austria)
Felix Wanschitz, Univ. of Vienna General Hospital (Austria)
Rolf Ewers, Univ. of Vienna General Hospital (Austria)
Helmar Bergmann, Univ. of Vienna General Hospital (Austria)
Franz Watzinger, Univ. of Vienna General Hospital (Austria)
Felix Wanschitz, Univ. of Vienna General Hospital (Austria)
Rolf Ewers, Univ. of Vienna General Hospital (Austria)
Helmar Bergmann, Univ. of Vienna General Hospital (Austria)
Published in SPIE Proceedings Vol. 4319:
Medical Imaging 2001: Visualization, Display, and Image-Guided Procedures
Seong Ki Mun, Editor(s)
© SPIE. Terms of Use