Share Email Print
cover

Proceedings Paper

Optimization of integrated optical ring microresonator structure for sensitive absorption spectroscopy (Conference Presentation)

Paper Abstract

Optical ring micro-resonators (OMR) can be integrated onto chips to obtain sensitive, robust, low cost and portable sensor systems. They are used for in-situ real time detection of specific molecules by specialized or non- specialized persons. Target analytes, homogeneously spread in the cladding layer, induces a complex refractive index variation Δncl of the OMR waveguides upper cladding. In this study, we propose an optimized analytical approach to OMR designs in terms of bulk sensitivity. Those type of sensors are based on the evanescent field sensing. Interaction between the evanescent field and the analytes induces resonance wavelengths modifications. The main sensing strategy is based on resonant wavelength shift measurement. However, contrast variation, due to the absorption coefficient linked to analytes concentration, can also be measured. Colorimetric reactions, used to obtain a specific sensor, change significantly the light intensity in a specific peak of the transmission spectrum. This is due to the complex formation between a specific ligand and a heavy metal, such as hexavalent chromium and 1,5 diphenylcarbazide. From the well-known ring resonator’s transmission expression, we can establish an analytical model of sensitivity’s dependence on geometric dimensions. Sensitivity in influenced by the round-trip attenuation coefficient a, the auto-coupling coefficient τ, the optical path and the ratio of guided power into the cladding Γcl. We validated our approach with FDTD simulation of OMR’s response for a 15 μm radius. This analytical approach makes it possible, from the waveguide propagation structure and propagation losses, to obtain both the optimal ring radius and the resonator gap in order to obtain maximum sensitivity. Based on optical characterization of OMR, measured variations of 1% power drop at resonance should allow variation measurement on the extinction coefficient of ∆ni = 10−6.

Paper Details

Date Published: 1 April 2020
PDF
Proc. SPIE 11361, Biophotonics in Point-of-Care, 113610R (1 April 2020);
Show Author Affiliations
Pauline Girault, Univ. de Sherbrooke (Canada)
Guillaume Beaudin, Univ. de Sherbrooke (Canada)
Miguel Diez, Lab. d'Intégration du Matériau au Système (France)
Simon Joly, IMS Lab. (France)
Laurent Oyhenart, Lab. d'Intégration du Matériau au Système (France)
Michael Canva, Univ. de Sherbrooke (Canada)
Paul Charette, Univ. de Sherbrooke (Canada)
Laurent Bechou, Lab. d'Intégration du Matériau au Système (France)


Published in SPIE Proceedings Vol. 11361:
Biophotonics in Point-of-Care
Michael T. Canva; Ambra Giannetti; Hatice Altug; Julien Moreau, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray