Optimization of energy thresholds in photon-counting CT via a virtual clinical trial
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

In photon-counting CT, detector energy thresholds directly affect image quality attributes such as contrast and noise. The purpose of this study was to identify optimum energy thresholds using a comprehensive virtual clinical trial platform. The virtual trial was done using a computational, anthropomorphic phantom and a photon-counting CT simulator. The phantom (adult male, 50th percentile body mass index) was chosen from the library of extended cardiac-torso (XCAT) phantoms. A vessel growth algorithm was used to model detailed hepatic arteries within the liver. Five computational lesions were inserted to the liver. The phantom was “imaged” with iodinated contrast at three contrast phases, i.e. arterial, portal venous, and delayed phases. All virtual sinograms were simulated using a validated CT simulator (DukeSim) modeling a prototype photon-counting scanner (CounT, Siemens Healthcare). The simulator included an energy- and threshold-dependent detector model accounting for X-ray and electronic effects and noise. At each contrast phase, the phantom was imaged at 35 detector energy threshold combinations with five lower-energy thresholds (20-40 keV) and seven upper-energy thresholds (50-80 keV). For each scan, two “threshold” images (photons detected beyond a threshold) and one “bin” image (photons detected between the two thresholds) were acquired. Noise magnitude, image contrast, and contrast-to-noise ratio (CNR) were measured in the aorta and the liver lesions. Optimum energy thresholds were identified as those yielding higher CNRs. From the simulations, noise magnitude was found to increase and CNR decrease with the increase in energy thresholds. Keeping the low threshold constant, the noise decreased and CNR increased with the increase in the upper energy threshold. Therefore, our results suggest that a combination of a lower threshold at 20-30 keV and upper threshold at 80 keV maximize the image quality. This study demonstrates an application of a virtual trial platform to quantify and optimize the quality of photon-counting CT.

Paper Details

Date Published: 16 March 2020
PDF: 6 pages
Proc. SPIE 11312, Medical Imaging 2020: Physics of Medical Imaging, 113121Y (16 March 2020); doi: 10.1117/12.2549055
Show Author Affiliations
Ehsan Abadi, Duke Univ. (United States)
Jayasai Rajagopal, Duke Univ. (United States)
NIH Clinical Ctr. (United States)
Thomas Sauer, Duke Univ. (United States)
Elizabeth Jones, NIH Clincal Ctr. (United States)
W. Paul Segars, Duke Univ. (United States)
Ehsan Samei, Duke Univ. (United States)


Published in SPIE Proceedings Vol. 11312:
Medical Imaging 2020: Physics of Medical Imaging
Guang-Hong Chen; Hilde Bosmans, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray