Share Email Print
cover

Proceedings Paper

Estimating visual acuity from a single wavefront measurement
Author(s): Derek Nankivil; Thomas D. Raymond; Greg Hofmann; Daniel R. Neal
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

Wavefront metrics such as root mean squared error provide excellent descriptions of optical quality but the connection to visual performance is not directly interpretable from the wavefront alone. Converting to visual acuity (VA) would provide a more accessible assessment of the effect of ocular wavefront. In this study, multiple measurements of wavefront and pupil diameter were acquired at 1 cd/m2 using the iDesign 1.3 (Johnson and Johnson Surgical Vision) in 552 eyes of 293 subjects. Uncorrected (UC) and best corrected (BC) VA were measured at 4m for each eye at 100 cd/m2 . VA was estimated using a neural contrast sensitivity function (NCSF) weighted modulation transfer function (MTF). To estimate BCVA, sphere and astigmatism terms were nulled. For each subject, classification was performed using random forest considering estimated VA, age, measured pupil diameter, manifest refraction spherical equivalent, manifest refraction cylinder and gender. Across all measurements, predicted differed from measured UCVA by -0.11 and BCVA by +1.6 (-10logMAR). The NCSF-based model predicts population mean VA to within approximately 2-lines but cannot predict an individual’s VA well, supporting the notion that other factors need to be considered to obtain more accurate estimates of VA. Classification with the random forest approach improved the accuracy of estimates of an individual subject’s VA; approximately 95% of the estimates match the measured VA.

Paper Details

Date Published: 19 February 2020
PDF: 10 pages
Proc. SPIE 11218, Ophthalmic Technologies XXX, 1121822 (19 February 2020); doi: 10.1117/12.2548645
Show Author Affiliations
Derek Nankivil, Johnson & Johnson Vision Care, Inc. (United States)
Thomas D. Raymond, Johnson & Johnson Surgical Vision, Inc. (United States)
Greg Hofmann, Johnson & Johnson Vision Care, Inc. (United States)
Daniel R. Neal, Johnson & Johnson Surgical Vision, Inc. (United States)


Published in SPIE Proceedings Vol. 11218:
Ophthalmic Technologies XXX
Fabrice Manns; Arthur Ho; Per G. Söderberg, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray