Patient evaluation of breast shape-corrected tomosynthesis reconstruction
Author(s): Koen Michielsen; Tsvetanka Rangelova; Ioannis Sechopoulos
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

Iterative reconstruction is a good match with the sparsely sampled limited angle data generated by breast tomosynthesis systems. However, it suffers from a specific artifact near the breast edge where it overestimates the x-ray path length, resulting in a considerable underestimation of the reconstructed linear attenuation coefficients. In this work, we present the application of a method that uses the measured 3D breast shape to reduce these artifacts in patient data, by including this information as an additional constraint in the image reconstruction process. A series of 50 patients undergoing breast tomosynthesis were additionally imaged with a pair of structured light cameras placed left and right of the mammography unit. These 3D surfaces were then aligned with the help of the backprojected breast outline from the x-ray data to form a single contour following the true breast shape. This was then further processed to generate a binary 3D mask set to 1 inside and to 0 outside the breast, and used as constraint in the reconstruction. Due to incomplete coverage and image artifacts, this mask was created successfully for only 19 out of 50 cases. Reconstructions were created with and without this constraint, and comparing attenuation profiles found that the artifact was almost completely corrected, bringing the reconstructed attenuation near the breast edge to the same level as the central region. Further visual inspection does show that higher quality optical 3D measurements and more precise alignment between optical and x-ray data are needed to avoid introducing new artifacts in the reconstruction.

Paper Details

Date Published: 1 March 2019
PDF: 6 pages
Proc. SPIE 10948, Medical Imaging 2019: Physics of Medical Imaging, 1094813 (1 March 2019); doi: 10.1117/12.2513436
Show Author Affiliations
Koen Michielsen, Radboud Univ. Medical Ctr. (Netherlands)
Tsvetanka Rangelova, Radboud Univ. Medical Ctr. (Netherlands)
Ioannis Sechopoulos, Radboud Univ. Medical Ctr. (Netherlands)
Dutch Reference Ctr. for Screening (Netherlands)


Published in SPIE Proceedings Vol. 10948:
Medical Imaging 2019: Physics of Medical Imaging
Taly Gilat Schmidt; Guang-Hong Chen; Hilde Bosmans, Editor(s)

© SPIE. Terms of Use
Back to Top