Share Email Print
cover

Proceedings Paper

Performance evaluation of a Se/CMOS prototype x-ray detector with the Apodized Aperture Pixel (AAP) design
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

An x-ray detector’s ability to produce high signal-to-noise ratio (SNR) images for a given exposure is described by the detective quantum efficiency (DQE) as a function of spatial frequency. Current mammography and radiography detectors have poor DQE performance at high frequencies due to noise aliasing when using a high- resolution converter layer. The Apodized-Aperture Pixel (AAP) design is novel detector design that increases high-frequency DQE by removing noise aliasing using smaller sensor elements (eg. 5 - 50 μm) than image pixel size (eg. 50 - 200 μm). The purpose of this work is to implement the AAP design on a selenium (Se) CMOS micro-sensor prototype with 7.8 × 7.8 μm size elements. Conventional (binned) and AAP images with 47 μm pixel size were synthesized and used to measure the modulation transfer function (MTF), normalized Wiener noise power spectrum (NNPS) and DQE. A micro-focus x-ray source (with a tungsten target) and a 60kV beam filtered with 2mm of aluminum was used to measure performance with DQEPro (DQEInstruments Inc., London, Canada) in a dynamic image acquisition mode at a high exposure level (9.7mR). The AAP design has 1.5x greater MTF near the image cut-off frequency (uc = 10.6 cyc/mm) than conventional design. DQE near ucwas 2.5x greater with the AAP design than conventional, and specimen imaging of a kidney stone shows greater SNR of fine-detail in the AAP image.

Paper Details

Date Published: 1 March 2019
PDF: 11 pages
Proc. SPIE 10948, Medical Imaging 2019: Physics of Medical Imaging, 1094816 (1 March 2019); doi: 10.1117/12.2512954
Show Author Affiliations
Tomi F. Nano, Robarts Research Institute (Canada)
Western Univ. (Canada)
Christopher C. Scott, Univ. of Waterloo (Canada)
KA Imaging Inc. (Canada)
Yunzhe Li, Univ. of Waterloo (Canada)
KA Imaging Inc. (Canada)
Celal Con, Univ. of Waterloo (Canada)
KA Imaging Inc. (Canada)
Karim S. Karim, Univ. of Waterloo (Canada)
KA Imaging Inc. (Canada)
Ian A. Cunningham, Robarts Research Institute (Canada)
Western Univ. (Canada)


Published in SPIE Proceedings Vol. 10948:
Medical Imaging 2019: Physics of Medical Imaging
Taly Gilat Schmidt; Guang-Hong Chen; Hilde Bosmans, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray