
Proceedings Paper
Optical stent inspection of surface texture and coating thicknessFormat | Member Price | Non-Member Price |
---|---|---|
$17.00 | $21.00 |
Paper Abstract
Stent quality control is a critical process. Coronary stents have to be inspected 100% so no defective stent is implanted into a human body. We have developed a high numerical aperture optical stent inspection system able to acquire both 2D and 3D images. Combining a rotational stage, an area camera with line-scan capability and a triple illumination arrangement, unrolled sections of the outer, inner, and sidewalls surfaces are obtained with high resolution. During stent inspection, surface roughness and coating thickness uniformity is of high interest. Due to the non-planar shape of the surface of the stents, the thickness values of the coating need to be corrected with the 3D surface local slopes. A theoretical model and a simulation are proposed, and a measurement with white light interferometry is shown. Confocal and spectroscopic reflectometry showed to be limited in this application due to stent surface roughness. Due to the high numerical aperture of the optical system, only certain parts of the stent are in focus, which is a problem for defect detection, specifically on the sidewalls. In order to obtain fully focused 2D images, an extended depth of field algorithm has been implemented. A comparison between pixel variance and Laplacian filtering is shown. To recover the stack image, two different methods are proposed: maximum projection and weighted intensity. Finally, we also discuss the implementation of the processing algorithms in both the CPU and GPU, targeting real-time 2-Million pixel image acquisition at 50 frames per second.
Paper Details
Date Published: 20 February 2017
PDF: 11 pages
Proc. SPIE 10110, Photonic Instrumentation Engineering IV, 1011007 (20 February 2017); doi: 10.1117/12.2249614
Published in SPIE Proceedings Vol. 10110:
Photonic Instrumentation Engineering IV
Yakov G. Soskind; Craig Olson, Editor(s)
PDF: 11 pages
Proc. SPIE 10110, Photonic Instrumentation Engineering IV, 1011007 (20 February 2017); doi: 10.1117/12.2249614
Show Author Affiliations
Carlos Bermudez, Technical Univ. of Catalonia (Spain)
Sensofar-Tech, S.L. (Spain)
Ferran Laguarta, Technical Univ. of Catalonia (Spain)
Cristina Cadevall, Technical Univ. of Catalonia (Spain)
Sensofar-Tech, S.L. (Spain)
Sensofar-Tech, S.L. (Spain)
Ferran Laguarta, Technical Univ. of Catalonia (Spain)
Cristina Cadevall, Technical Univ. of Catalonia (Spain)
Sensofar-Tech, S.L. (Spain)
Aitor Matilla, Sensofar-Tech, S.L. (Spain)
Sergi Ibañez, Sensofar Medical, S.L. (Spain)
Roger Artigas, Technical Univ. of Catalonia (Spain)
Sensofar-Tech, S.L. (Spain)
Sergi Ibañez, Sensofar Medical, S.L. (Spain)
Roger Artigas, Technical Univ. of Catalonia (Spain)
Sensofar-Tech, S.L. (Spain)
Published in SPIE Proceedings Vol. 10110:
Photonic Instrumentation Engineering IV
Yakov G. Soskind; Craig Olson, Editor(s)
© SPIE. Terms of Use
