Proceedings Paper
Scanning transmission x-ray microscope at the NSLS: from XANES to cryoFormat | Member Price | Non-Member Price |
---|---|---|
$17.00 | $21.00 |
Paper Abstract
The Stony Brook scanning transmission x-ray microscope (STXM) has been operating at the X1A beamline at the NSLS since 1989. A large number of users have used it to study biological and material science samples. We report on changes that have been performed in the past year, and present recent results. To stabilize the position of the micro probe when doing spectral scans at high spatial resolution, we have constructed a piezo-driven flexure stage which carries out the focusing motion of the zone plate needed when changing the wavelength. To overcome our detector limitation set by saturation of our gas-flow counter at count rates around 1 MHz, we are installing an avalanche photo diode with an active quenching circuit which we expect to respond linearly to count rates in excess of 10 MHz. We have improved the enclosure for STXM to improve the stability of the Helium atmosphere while taking data. This reduces fluctuations of beam absorption and, therefore, noise in the image. A fast shutter has been installed in the beam line. We are also developing a cryo- STXM which is designed for imaging frozen hydrated samples at temperatures below 120 K. At low temperatures, radiation sensitive samples can tolerate a considerably higher radiation dose than at room temperature. This should improve the resolution obtainable from biological samples and should make recording of multiple images of the same sample area possible while minimizing the effects of radiation damage. This should enable us to perform elemental and chemical mapping at high resolution, and to record the large number of views needed for 3D reconstruction of the object.
Paper Details
Date Published: 25 September 1995
PDF: 12 pages
Proc. SPIE 2516, X-Ray Microbeam Technology and Applications, (25 September 1995); doi: 10.1117/12.221685
Published in SPIE Proceedings Vol. 2516:
X-Ray Microbeam Technology and Applications
Wenbing Yun, Editor(s)
PDF: 12 pages
Proc. SPIE 2516, X-Ray Microbeam Technology and Applications, (25 September 1995); doi: 10.1117/12.221685
Show Author Affiliations
Jorg M. Maser, SUNY/Stony Brook (United States)
Henry N. Chapman, SUNY/Stony Brook (United States)
Chris J. Jacobsen, SUNY/Stony Brook (United States)
Alex Kalinovsky, SUNY/Stony Brook (United States)
Janos Kirz, SUNY/Stony Brook (United States)
Angelika Osanna, SUNY/Stony Brook (United States)
Henry N. Chapman, SUNY/Stony Brook (United States)
Chris J. Jacobsen, SUNY/Stony Brook (United States)
Alex Kalinovsky, SUNY/Stony Brook (United States)
Janos Kirz, SUNY/Stony Brook (United States)
Angelika Osanna, SUNY/Stony Brook (United States)
Steve Spector, SUNY/Stony Brook (United States)
Steve Wang, SUNY/Stony Brook (United States)
Barry L. Winn, SUNY/Stony Brook (United States)
Sue Wirick, SUNY/Stony Brook (United States)
Xiaodong Zhang, SUNY/Stony Brook (United States)
Steve Wang, SUNY/Stony Brook (United States)
Barry L. Winn, SUNY/Stony Brook (United States)
Sue Wirick, SUNY/Stony Brook (United States)
Xiaodong Zhang, SUNY/Stony Brook (United States)
Published in SPIE Proceedings Vol. 2516:
X-Ray Microbeam Technology and Applications
Wenbing Yun, Editor(s)
© SPIE. Terms of Use