Share Email Print
cover

Proceedings Paper

Region of interest processing for iterative reconstruction in x-ray computed tomography
Author(s): Felix K. Kopp; Radin A. Nasirudin; Kai Mei; Andreas Fehringer; Franz Pfeiffer; Ernst J. Rummeny M.D.; Peter B. Noël
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

The recent advancements in the graphics card technology raised the performance of parallel computing and contributed to the introduction of iterative reconstruction methods for x-ray computed tomography in clinical CT scanners. Iterative maximum likelihood (ML) based reconstruction methods are known to reduce image noise and to improve the diagnostic quality of low-dose CT. However, iterative reconstruction of a region of interest (ROI), especially ML based, is challenging. But for some clinical procedures, like cardiac CT, only a ROI is needed for diagnostics. A high-resolution reconstruction of the full field of view (FOV) consumes unnecessary computation effort that results in a slower reconstruction than clinically acceptable. In this work, we present an extension and evaluation of an existing ROI processing algorithm. Especially improvements for the equalization between regions inside and outside of a ROI are proposed. The evaluation was done on data collected from a clinical CT scanner. The performance of the different algorithms is qualitatively and quantitatively assessed. Our solution to the ROI problem provides an increase in signal-to-noise ratio and leads to visually less noise in the final reconstruction. The reconstruction speed of our technique was observed to be comparable with other previous proposed techniques. The development of ROI processing algorithms in combination with iterative reconstruction will provide higher diagnostic quality in the near future.

Paper Details

Date Published: 18 March 2015
PDF: 7 pages
Proc. SPIE 9412, Medical Imaging 2015: Physics of Medical Imaging, 94122E (18 March 2015); doi: 10.1117/12.2081911
Show Author Affiliations
Felix K. Kopp, Technische Univ. München (Germany)
Radin A. Nasirudin, Technische Univ. München (Germany)
Kai Mei, Technische Univ. München (Germany)
Andreas Fehringer, Technische Univ. München (Germany)
Franz Pfeiffer, Technische Univ. München (Germany)
Ernst J. Rummeny M.D., Technische Univ. München (Germany)
Peter B. Noël, Technische Univ. München (Germany)


Published in SPIE Proceedings Vol. 9412:
Medical Imaging 2015: Physics of Medical Imaging
Christoph Hoeschen; Despina Kontos, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray