Proceedings Paper
Design and simulation of integrated optical interferometers fabricated in polymer foilsFormat | Member Price | Non-Member Price |
---|---|---|
$17.00 | $21.00 |
Paper Abstract
Integrated optical Mach-Zehnder interferometers (MZI) can be used as high sensitivity sensors through the
interaction of the evanescent field of the waveguide with liquids or gases surrounding the sensor. We present
here the design of polymer-based MZIs fabricated by hot-embossing and printing technologies. Simulations of an
integrated MZI system with regard to variations of the waveguide cross-section and the refractive indices of the
core layer are carried out to guarantee single mode behavior and optimize high sensitivity to external refractive
index changes of analytes. The simulation of propagation losses induced by the Y-coupleres is also presented.
Furthermore, transmission as a function of different interaction window lengths are also simulated on the entire
MZI structure using a mixture of water and ethanol as an analyte on the sensing arm. Finally, we calculate the
coupling efficiency of a laser diode into a tapered waveguide and estimate that a value of 30% is possible.
Paper Details
Date Published: 27 February 2015
PDF: 8 pages
Proc. SPIE 9365, Integrated Optics: Devices, Materials, and Technologies XIX, 93651F (27 February 2015); doi: 10.1117/12.2079276
Published in SPIE Proceedings Vol. 9365:
Integrated Optics: Devices, Materials, and Technologies XIX
Jean-Emmanuel Broquin; Gualtiero Nunzi Conti, Editor(s)
PDF: 8 pages
Proc. SPIE 9365, Integrated Optics: Devices, Materials, and Technologies XIX, 93651F (27 February 2015); doi: 10.1117/12.2079276
Show Author Affiliations
Hans Zappe, Univ. of Freiburg (Germany)
Published in SPIE Proceedings Vol. 9365:
Integrated Optics: Devices, Materials, and Technologies XIX
Jean-Emmanuel Broquin; Gualtiero Nunzi Conti, Editor(s)
© SPIE. Terms of Use