
Proceedings Paper
P05 imaging beamline at PETRA III: first resultsFormat | Member Price | Non-Member Price |
---|---|---|
$17.00 | $21.00 |
Paper Abstract
The imaging beamline (IBL/P05) operated by Helmholtz Zentrum Geesthacht (HZG) at the DESY PETRA III storage ring consists of two experimental stations: A micro tomography and a nano tomography end station. Here an overview of the experimental setups and the data acquisition will be given. In addition some first results out of the wide range of applications using the micro tomography station at P05 will be shown. Furthermore, we present first results of the nano tomography end station. These were obtained with an x–ray microscopy setup, which currently operates at energies of 17.4 and 30 keV using polymer compound refractive lenses (CRLs) and rolled prism lenses. Taken together these results clearly show the high potential of the newly built imaging beamline IBL.
Paper Details
Date Published: 11 September 2014
PDF: 8 pages
Proc. SPIE 9212, Developments in X-Ray Tomography IX, 92120O (11 September 2014); doi: 10.1117/12.2061768
Published in SPIE Proceedings Vol. 9212:
Developments in X-Ray Tomography IX
Stuart R. Stock, Editor(s)
PDF: 8 pages
Proc. SPIE 9212, Developments in X-Ray Tomography IX, 92120O (11 September 2014); doi: 10.1117/12.2061768
Show Author Affiliations
Imke Greving, Helmholtz-Zentrum Geesthacht (Germany)
Fabian Wilde, Helmholtz-Zentrum Geesthacht (Germany)
Malte Ogurreck, Helmholtz-Zentrum Geesthacht (Germany)
Julia Herzen, Helmholtz-Zentrum Geesthacht (Germany)
Technische Univ. München (Germany)
Jörg U. Hammel, Helmholtz-Zentrum Geesthacht (Germany)
Alexander Hipp, Helmholtz-Zentrum Geesthacht (Germany)
Fabian Wilde, Helmholtz-Zentrum Geesthacht (Germany)
Malte Ogurreck, Helmholtz-Zentrum Geesthacht (Germany)
Julia Herzen, Helmholtz-Zentrum Geesthacht (Germany)
Technische Univ. München (Germany)
Jörg U. Hammel, Helmholtz-Zentrum Geesthacht (Germany)
Alexander Hipp, Helmholtz-Zentrum Geesthacht (Germany)
Frank Friedrich, Univ. Hamburg (Germany)
Lars Lottermoser, Helmholtz-Zentrum Geesthacht (Germany)
Thomas Dose, Helmholtz-Zentrum Geesthacht (Germany)
Hilmar Burmester, Helmholtz-Zentrum Geesthacht (Germany)
Martin Müller, Helmholtz Zentrum Geesthacht (Germany)
Felix Beckmann, Helmholtz-Zentrum Geesthacht (Germany)
Lars Lottermoser, Helmholtz-Zentrum Geesthacht (Germany)
Thomas Dose, Helmholtz-Zentrum Geesthacht (Germany)
Hilmar Burmester, Helmholtz-Zentrum Geesthacht (Germany)
Martin Müller, Helmholtz Zentrum Geesthacht (Germany)
Felix Beckmann, Helmholtz-Zentrum Geesthacht (Germany)
Published in SPIE Proceedings Vol. 9212:
Developments in X-Ray Tomography IX
Stuart R. Stock, Editor(s)
© SPIE. Terms of Use
