Share Email Print
cover

Proceedings Paper

The GRAVITY spectrometers: design report of the optomechanics and active cryogenic mechanisms
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

The work package of the University of Cologne within the GRAVITY consortium included the development and manufacturing of two spectrometers for the beam combiner instrument. Both spectrometers are optimized for different tasks. The science spectrometer provides 3 different spectral resolutions. In the highest resolution the length of the spectral lines is close to the borders of the imaging area of the detector. Also the integration time of these high resolution images is relative long. Therefor the optical pathes have to be controlled by the feedback of a faster spectrometer. The fringe tracking spectrometer has only one low resolution to allow much shorter integration times. This spectrometer provides a feedback for the control loops which stabilize the optical pathes of the light from the telescope to the instrument. This is a new key feature of the whole GRAVITY instrument. Based on the optical layout my work was the design of the mechanical structure, mountings, passive and active adjustment mechanisms. This paper gives a short review about the active mechanisms and the compliant lens mounts. They are used similarly in both spectrometers. Due to the observation and analysis of near-infrared light the mechanisms have to run at cryogenic temperatures and in a high vacuum. Except the linear stages, the motorized mechanisms will get used for several times per observation.

Paper Details

Date Published: 28 July 2014
PDF: 9 pages
Proc. SPIE 9147, Ground-based and Airborne Instrumentation for Astronomy V, 91472M (28 July 2014); doi: 10.1117/12.2056703
Show Author Affiliations
Michael Wiest, Univ. zu Köln (Germany)
Senol Yazici, Univ. zu Köln (Germany)
Sebastian Fischer, Deutsches Zentrum für Luft- und Raumfahrt e.V. (Germany)
Markus Thiel, Kayser-Threde GmbH (Germany)
Marcus Haug, Max-Planck-Institut für extraterrestrische Physik (Germany)
Constanza Araujo-Hauck, Gemini Observatory (Chile)
Christian Straubmeier, Univ. zu Köln (Germany)
Imke Wank, Univ. zu Köln (Germany)
Frank Eisenhauer, Max-Planck-Institut für extraterrestrische Physik (Germany)
Guy Perrin, Lab. d'Etudes Spatiales et d'Instrumentation en Astrophysique (France)
LESIA, Observatoire de Paris, CNRS, UPMC, Univ. Paris Diderot (France)
Groupement d’Intérêt Scientifique PHASE (France)
Wolfgang Brandner, Max-Planck-Institut für Astronomie (Germany)
Karine Perraut, Lab. d’Astrophysique Observatoire de Grenoble (France)
Antonio Amorim, CENTRA-SIM (Portugal)
Markus Schöller, European Southern Observatory (Germany)
Andreas Eckart, Univ. zu Köln (Germany)
Max-Planck-Institut für Radioastronomie (Germany)


Published in SPIE Proceedings Vol. 9147:
Ground-based and Airborne Instrumentation for Astronomy V
Suzanne K. Ramsay; Ian S. McLean; Hideki Takami, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray