Paper Abstract

Purpose: To estimate conversion factors for calculating effective dose (E) and organ dose taking tube current modulation (TCM) and patient size into account in adult thorax and abdomen CT examinations. Method: 99 consecutive adult patients were included in this study. All examinations were performed with TCM (CareDose 4D. Siemens Definition Flash) at 120 kVp and 110 (thorax) and 200 (abdomen) reference mAs. E and organ dose were estimated with PCXMC 2.0 (STUK. Helsinki. Finland). using an extension of the software from a planar geometry to spiral acquisitions of aCT scanner. This software accounts for patient size by rescaling the anthropomorphic phantom to actual patient weights and heights. E and organ doses were normalized to the CTDivol as reported in the patient's report. These conversion factors (dE and dorgan were studied as a function of different patient metrics: lateral and anterior-posterior (AP) diameter. sum of the lateral and AP diameter, area of a cross section image and effective diameter. Results:. No trend was found for any of the metrics neither forE nor for the organs investigated (lungs. breasts. stomach and liver). Average value ± 2 standard deviation were calculated. For a thorax examination, the average dE was 0.57 ± 0.14 mSv/mGy. dlungs was 1.26 ± 0.28 mGy/mGy and dbreasts was 1.29 ± 0.40 mGy/mGy. For an abdomen scan dE was 0.82 ± 0.18. mSv/mGy. d,tomooh was 1.42 ± 0.26 mGy/mGy. dliver was 1.42 ± 0.30 mGy/mGy. Conclusion:. For the scanner studied, average conversion factors, which account for TCM and patient size, were proposed. This is a first step towards patient-specific dosimetry.

Paper Details

Date Published: 6 March 2013
PDF: 8 pages
Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 866842 (6 March 2013); doi: 10.1117/12.2007880
Show Author Affiliations
X. Lopez-Rendon, UZ Leuven (Belgium)
F. Zanca, UZ Leuven (Belgium)
R. Oyen, UZ Leuven (Belgium)
H. Bosmans, UZ Leuven (Belgium)


Published in SPIE Proceedings Vol. 8668:
Medical Imaging 2013: Physics of Medical Imaging
Robert M. Nishikawa; Bruce R. Whiting; Christoph Hoeschen, Editor(s)

© SPIE. Terms of Use
Back to Top
PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research
Forgot your username?
close_icon_gray