Share Email Print
cover

Proceedings Paper

Double-2D: an innovative numerical procedure for the thermal performance evaluation of actively cooled components
Author(s): Mario Merola
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

An innovative diverter concept for a thermonuclear fusion reactor is being studied at the Institute for Advanced Materials of the Joint Research Centre of the European Communities. It is made of a single material, an ultrahigh thermal conductivity carbon fiber reinforced graphite (CFC) composite; the coolant is helium gas. When looking at the new diverter concept, it is necessary to make several numerical calculations in order to investigate the influence of the various parameters to be optimized. This paper shows a new numerical procedure which has been developed to avoid a complete 3D-calculation.

Paper Details

Date Published: 25 February 1993
PDF: 9 pages
Proc. SPIE 1739, High Heat Flux Engineering, (25 February 1993); doi: 10.1117/12.140519
Show Author Affiliations
Mario Merola, Joint Research Ctr. (Italy)


Published in SPIE Proceedings Vol. 1739:
High Heat Flux Engineering
Ali M. Khounsary, Editor(s)

© SPIE. Terms of Use