SPIE Membership Get updates from SPIE Newsroom
  • Newsroom Home
  • Astronomy
  • Biomedical Optics & Medical Imaging
  • Defense & Security
  • Electronic Imaging & Signal Processing
  • Illumination & Displays
  • Lasers & Sources
  • Micro/Nano Lithography
  • Nanotechnology
  • Optical Design & Engineering
  • Optoelectronics & Communications
  • Remote Sensing
  • Sensing & Measurement
  • Solar & Alternative Energy
  • Sign up for Newsroom E-Alerts
  • Information for:
    Advertisers
SPIE Photonics West 2018 | Call for Papers

SPIE Defense + Commercial Sensing 2018 | Call for Papers

SPIE Journals OPEN ACCESS

SPIE PRESS

SPIE PRESS

Print PageEmail PageView PDF

Biomedical Optics & Medical Imaging

Full-field imaging of cerebral blood flow in freely moving animals

A new miniature imager captures full-field cerebral blood flow in ambulating rats based on high-resolution laser speckle contrast analysis.
17 May 2012, SPIE Newsroom. DOI: 10.1117/2.1201205.004184

Functional and structural imaging of the cerebral neurovascular system has proven to be an important tool in neuroscience research. For example, functional magnetic resonance imaging and positron emission tomography provide 3D information about brain blood volume, which changes in response to metabolic alterations. But spatiotemporal resolution is limited, and subjects must be constrained or under anesthesia. In many areas of neuroscience investigation, neurovascular responses in the awake state are of great interest because anesthesia may affect the way neural circuits work.

In recent years, laser speckle imaging (LSI) based on laser speckle contrast analysis (LASCA) has been developed for monitoring cerebral blood flow (CBF). It has found application in biomedical research, e.g., hemodynamic response induced by tumor,1 retinal damage,2 or stroke,3 or peripheral electrical stimulation.4 Inspired by the miniature head-stage-based two-photon microscope and laser Doppler recording for freely moving animals, we developed a small head-mounted LSI system for cerebral vascular imaging.5 Two major challenges of such a device include integrating the image sensor, light source, micro-lens, and data acquisition chips into a wearable package that is sufficiently small and lightweight (e.g., ∼20g), and removing motion artifacts when the animal (e.g., a rat) is moving without losing the data resolution.


Figure 1. (a) Schematic illustration of a miniature head-mounted imager. (Adapted from Miao et al.5) (b) A rat wearing a laser speckle imager in a conscious state of behavior. PCB: Printed circuit board.

The imaging system has two components: a high-resolution CMOS sensor (1024×1396 pixel resolution, 8-bit data precision, 35MHz pixel clock, 50fps frame rate, 10ms exposure time, 640×640 pixel area of interest) on a portable printed circuit board (3.6×3.6cm) that is used to record the speckle images from the cerebral cortex; and four collection lenses that serve together as an imaging lens system (3.44mm radius, 6.2mm focal length, 20mm minimum focus distance). A fiber bundle delivers the coherent laser light (780nm, collimated from a laser diode). Figure 1 shows the entire imaging system mounted on a freely moving rat. Videos show a rat wearing a head-mounted LSI imager in an ambulatory state, and a rat undergoing treadmill training in an experiment related to rehabilitation following stroke.6, 7

We implemented two techniques to ensure high-spatio-temporal-resolution imaging. The first is registered LASCA8 for correcting motion artifacts by overlaying speckle images. The second is a random process estimator to improve the signal-to-noise ratio of contrast images when using fewer frames.9 The imager provides high performance (161 pixels/mm resolution and <2% distortion), with each pixel corresponding to a 12.5×12.5μm cortical area that is sufficiently small for imaging tissue perfusion (i.e., blood flow at the capillary level). Figure 2 shows a typical contrast image obtained in a rat where the diameter of the smallest recognizable vessels was 50μm.


Figure 2. A typical contrast image obtained in a freely moving rat. The diameter of smallest recognizable vessels is only 50μm. (Adapted from Miao et al.5)

In summary, this miniature head-mounted LSI for full-field high-resolution imaging of CBF can be used in freely moving small animals, such as rats. The system offers the possibility to study the functional brain network of small conscious and ambulatory animals. As next steps, we plan to implement VLSI (very large scale integration) design to further reduce the size and weight of the imager for freely moving mice. We will also combine optical intrinsic signal imaging and LSI to enable our next-generation imager to simultaneously monitor CBF, blood volume, and (de)oxyhemoglobin.


Shanbao Tong
Shanghai Jiao Tong University
Shanghai, China

Shanbao Tong is a professor. He received his PhD in biomedical engineering from Shanghai Jiao Tong University (2002) and did his postdoctoral training from 2002 to 2005 at Johns Hopkins University. His research interests include neural signal processing, LSI, and cognitive neural engineering.

Peng Miao
Shanghai University
Shanghai, China

Peng Miao is currently an assistant professor. He received his PhD in biomedical engineering at Shanghai Jiao Tong University (2011). His research areas include LSI, optogenetics, and neurophysiology.


References:
1. D. Zhu, W. Lu, Y. Weng, H. Cui, Q. Luo, Monitoring thermal-induced changes in tumor blood flow and microvessels with laser speckle contrast imaging, Appl. Opt. 46(10), p. 1911-1917, 2007.
2. H. Cheng, Y. Yan, T. Duong, Temporal statistical analysis of laser speckle images and its application to retinal blood-flow imaging, Opt. Express 16(14), p. 214-219, 2008.
3. A. K. Dunn, H. Bolay, M. A. Moskowitz, D. A. Boas, Dynamic imaging of cerebral blood flow using laser speckle, J. Cereb. Blood Flow Metab. 21(3), p. 195-201, 2001.
4. T. Durduran, M. G. Burnett, G. Yu, C. Zhou, D. Furuya, A. G. Yodh, J. A. Detre, J. H. Greenberg, Spatiotemporal quantification of cerebral blood flow during functional activation in rat somatosensory cortex using laser-speckle flowmetry, J. Cereb. Blood Flow Metab. 24(5), p. 518-525, 2004.
5. P. Miao, H. Lu, Q. Liu, Y. Li, S. Tong, Laser speckle contrast imaging of cerebral blood flow in freely moving animals, J. Biomed. Opt. 16(9), p. 090502, 2011.
6. http://spie.org/documents/newsroom/videos/4184/Video1.mov Video shows a rat wearing a head-mounted LSI imager in a freely moving state. Credit: Peng Miao, Shanghai Jiao Tong University.
7. http://spie.org/documents/newsroom/videos/4184/Video2.mov Video shows a rat undergoing treadmill training in an experiment related to rehabilitation following stroke. Credit: Hongyang Lu, Shanghai Jiao Tong University.
8. P. Miao, A. Rege, N. Li, Y. Zhu, N. V. Thakor, S. Tong, High resolution cerebral blood flow imaging by registered laser speckle contrast analysis, IEEE Trans. Biomed. Eng. 57(5), p. 1152-1157, 2010.
9. P. Miao, N. Li, N. V. Thakor, S. Tong, Random process estimator for laser speckle imaging of cerebral blood flow, Opt. Express 18(1), p. 218-36, 2010.