Micro-thermography enables rapid inspection of defects in diode lasers

Manufacturers need a better way to inspect devices for defects before shipping diode lasers to customers.
07 February 2006
Anna Kozlowska, Jens W. Tomm, Piotr Wawrzyniak, and Fritz Weik

Diode lasers (DLs) are efficient light sources that are widely used in telecommunication, computer equipment, medicine, telemetry and material processing. Though the technology of low-power devices has already reached a level of maturity, the reliability of high-power DLs remains an issue. Diode laser bars could be widely used—e.g. for optical pumping of solid-state lasers—but due to reliability problems they frequently lose when in competition even with conventional lamp sources. In order to increase reliability, manufacturers need a better way to inspect devices for defects before shipping the DLs to customers.

Past approaches used to identify the defects inside the diode laser include microscopic, spectroscopic, and electrical methods.1 These methods are helpful in understanding and solving the degradation problems, but their complexity prevents their use in an industrial environment. Micro-thermography seems to be an ideal solution, especially if we take into account the enormous progress in the field of infrared (IR) imaging: improved spatial resolution, quasi-real-time operation and high detection sensitivity. Thermography has already been implemented for the inspection of high-power laser bar stacks.2 Also, our recent work has been devoted to the analysis of various thermal problems in DLs and DL bars.3–5

Our basic idea for this measurement relies on the fact that both defect creation and accumulation are typically accompanied by a local temperature increase that can be directly detected by micro-thermography. Moreover, the extension of this measurement system to include two spectral channels, together with analysis of thermal transients, allows our system to distinguish between pure thermal radiation and any other parasitic emission, such as deep-level luminescence.

To investigate problems related to fast and slow degradation of diode lasers we used devices made in-house. These were based on a double-barrier separate confinement heterostructure emitting at 808nm.6 Their design is intended to reduce fast-axis beam divergence. Figure 1 shows a schematic of our thermographic system. We used a camera sensitive in the wavelength range 1.5 – 5.5μm. Two filters, F1 and F2, define spectral channels in the near and mid IR.

 
Figure 1. Multi-spectral thermocamera system inspects a diode laser (DL) in two spectral ranges. Spectra show the sensitivity of the thermocamera as well as transmission curves of filters F1 and F2. TEC: thermoelectric cooler.
 

We captured mid-IR thermal images of DLs that were candidates for fast degradation. A DL with a hot spot at the front facet is shown in Figure 2(a). In the case of another DL, the defect is located deeper in the substrate and is visible as an extended warmed area, see Figure 2(b). If we shift the focal plane from the facet to the defect inside the cavity, however, we can image a localized hot spot, see Figure 2(c). Moreover, we have demonstrated3 that thermal profiling helps recognize defects that cannot be detected by simple visual inspection.

 
Figure 2. Thermographic images of defective diode lasers acquired in the mid IR. In (c), the focal point of the camera is shifted to 300μm below the laser's surface.
 

Near-IR images of diode lasers can show signs of slow degradation. We found that signals detected in this spectral channel are mainly caused by mid-gap deep-level luminescence.4,5 A comparison between a new DL and a DL aged for 3000 hours — see Figure 3(a,b) and (c,d) respectively—shows that, over time, the intensity of this type of luminescence increases in the near IR. Most probably, the concentration of deep-level defects increases during aging. On the other hand, re-absorption of light at the defect centers gives rise to increased heating, which was examined in the mid-IR range.5 The temperature increase as a result of long-term operation certainly limits the performance of the device.

 
Figure 3. Front view thermographic images acquired in the near IR for a new (a) and aged diode laser (c) and their lateral profiles (b) and (d), respectively, taken along the junction plane.
 

Summarizing, we have used a micro-thermographic method to investigate effects responsible for both fast and slow degradation of diode lasers. The results presented here pave the way for an advanced reliability screening methodology for high-power diode lasers and laser bars.


Authors
Anna Kozlowska and Piotr Wawrzyniak
Laser Laboratory, Institute of Electronic Materials Technology
Warsaw, Poland
Dr. Anna Kozlowska is the head of Laser Laboratory in the Institute of Electronic Material Technology in Warsaw (Poland). She is working on high-power diode laser technology and development of advanced characterization methods.
Jens W. Tomm and Fritz Weik
Max-Born-Institut fur Nichtlineare Optik und Kurzzeitspektroscopie
Berlin, Germany

PREMIUM CONTENT
Sign in to read the full article
Create a free SPIE account to get access to
premium articles and original research