Share Email Print
cover

Proceedings of SPIE Volume 9783

Medical Imaging 2016: Physics of Medical Imaging
Format Member Price Non-Member Price
Softcover $225.00 $300.00

Volume Details

Volume Number: 9783
Date Published: 22 June 2016
Softcover: 216 papers (1794) pages
ISBN: 9781510600188

Table of Contents
show all abstracts | hide all abstracts
Front Matter: Volume 9783
Author(s): Proceedings of SPIE
Quantification of resolution in multiplanar reconstructions for digital breast tomosynthesis
Author(s): Trevor L. Vent; Raymond J. Acciavatti; Young Joon Kwon; Andrew D. A. Maidment
Show Abstract
Stationary digital chest tomosynthesis for coronary artery calcium scoring
Author(s): Gongting Wu; Jiong Wang; Marci Potuzko; Allison Harman; Caleb Pearce; Jing Shan; Yueh Z. Lee; Otto Zhou; Jianping Lu
Show Abstract
A new generation of stationary digital breast tomosynthesis system with wider angular span and faster scanning time
Author(s): Jabari Calliste; Gongting Wu; Philip E. Laganis; Derrek Spronk; Houman Jafari; Kyle Olson; Bo Gao; Yueh Z. Lee; Otto Zhou; Jianping Lu
Show Abstract
Detection of microcalcification clusters by 2D-mammography and narrow and wide angle digital breast tomosynthesis
Author(s): Andria Hadjipanteli; Premkumar Elangovan; Padraig T. Looney; Alistair Mackenzie; Kevin Wells; David R. Dance; Kenneth C. Young
Show Abstract
Feasibility of reduced-dose 3D/4D-DSA using a weighted edge preserving filter
Author(s): Erick L. Oberstar; Michael A. Speidel; Brian J. Davis; Charles Strother; Charles Mistretta
Show Abstract
Generation of 3D synthetic breast tissue
Author(s): Premkumar Elangovan; David R. Dance; Kenneth C. Young; Kevin Wells
Show Abstract
Rayleigh imaging in spectral mammography
Author(s): Karl Berggren; Mats Danielsson; Erik Fredenberg
Show Abstract
Reproducing 2D breast mammography images with 3D printed phantoms
Author(s): Matthew Clark; Bahaa Ghammraoui; Andreu Badal
Show Abstract
Breast ultrasound tomography with two parallel transducer arrays
Author(s): Lianjie Huang; Junseob Shin; Ting Chen; Youzuo Lin; Kai Gao; Miranda Intrator; Kenneth Hanson
Show Abstract
A new, open-source, multi-modality digital breast phantom
Author(s): Christian G. Graff
Show Abstract
Estimating breast thickness for dual-energy subtraction in contrast-enhanced digital mammography using calibration phantoms
Author(s): Kristen C. Lau; Young Joon Kwon; Moez Karim Aziz; Raymond J. Acciavatti; Andrew D. A. Maidment
Show Abstract
EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)
Author(s): Simon R. Cherry; Ramsey D. Badawi; Terry Jones
Show Abstract
Dictionary-based image denoising for dual energy computed tomography
Author(s): Korbinian Mechlem; Sebastian Allner; Kai Mei; Franz Pfeiffer; Peter B. Noël
Show Abstract
Limited-angle multi-energy CT using joint clustering prior and sparsity regularization
Author(s): Huayu Zhang; Yuxiang Xing
Show Abstract
Twin robotic x-ray system for 2D radiographic and 3D cone-beam CT imaging
Author(s): Andreas Fieselmann; Jan Steinbrener; Anna K. Jerebko; Johannes M Voigt; Rosemarie Scholz; Ludwig Ritschl; Thomas Mertelmeier
Show Abstract
Image-based motion compensation for high-resolution extremities cone-beam CT
Author(s): A. Sisniega; J. W. Stayman; Q. Cao; J. Yorkston; J. H. Siewerdsen; W. Zbijewski
Show Abstract
Striped ratio grids for scatter estimation
Author(s): Scott S. Hsieh; Adam S. Wang; Josh Star-Lack
Show Abstract
Five-dimensional motion compensation for respiratory and cardiac motion with cone-beam CT of the thorax region
Author(s): Sebastian Sauppe; Andreas Hahn; Marcus Brehm; Pascal Paysan; Dieter Seghers; Marc Kachelrieß
Show Abstract
Over-exposure correction in knee cone-beam CT imaging with automatic exposure control using a partial low dose scan
Author(s): Jang-Hwan Choi; Kerstin Muller; Scott Hsieh; Andreas Maier; Garry Gold; Marc Levenston; Rebecca Fahrig
Show Abstract
Shifted detector super short scan reconstruction for the rotate-plus-shift trajectories and its application to C-arm CT systems
Author(s): Jan Kuntz; Michael Knaup; Christof Fleischmann; Marc Kachelrieß
Show Abstract
Single-shot x-ray phase contrast imaging with an algorithmic approach using spectral detection
Author(s): Mini Das; Chan-Soo Park; Nathaniel R. Fredette
Show Abstract
X-ray differential phase contrast imaging using a grating interferometer and a single photon counting detector
Author(s): Yongshuai Ge; Ran Zhang; Ke Li; Guang-Hong Chen
Show Abstract
Potential use of microbubbles (MBs) as contrast material in x-ray dark field (DF) imaging: How does the DF signal change with the characteristic parameters of the MBs?
Author(s): Ran Zhang; Bin Qin; Yongshuai Ge; Bruce Whiting; Ke Li; Flordeliza Villanueva; Guang-Hong Chen
Show Abstract
High-energy x-ray grating-based phase-contrast radiography of human anatomy
Author(s): Florian Horn; Christian Hauke; Sebastian Lachner; Veronika Ludwig; Georg Pelzer; Jens Rieger; Max Schuster; Maria Seifert; Johannes Wandner; Andreas Wolf; Thilo Michel; Gisela Anton
Show Abstract
Design and characterization of a dedicated cone-beam CT scanner for detection of acute intracranial hemorrhage
Author(s): J. Xu; A. Sisniega; W. Zbijewski; H. Dang; J. W. Stayman; X. Wang; D. H. Foos; N. Aygun; V. E. Koliatsos; J. H. Siewerdsen
Show Abstract
Mask free intravenous 3D digital subtraction angiography (IV 3D-DSA) from a single C-arm acquisition
Author(s): Yinsheng Li; Kai Niu; Pengfei Yang; Beveley Aagaard-Kienitz; David B. Niemann; Azam S. Ahmed; Charles Strother; Guang-Hong Chen
Show Abstract
C-arm cone beam CT perfusion imaging using the SMART-RECON algorithm to improve temporal sampling density and temporal resolution
Author(s): Yinsheng Li; Kai Niu; Ke Li; Sebastian Schafer; Kevin Royalty; Charles Strother; Guang-Hong Chen
Show Abstract
Nonlinear statistical reconstruction for flat-panel cone-beam CT with blur and correlated noise models
Author(s): Steven Tilley; Jeffrey H. Siewerdsen; Wojciech Zbijewski; J. Webster Stayman
Show Abstract
Automatic intrinsic cardiac and respiratory gating from cone-beam CT scans of the thorax region
Author(s): Andreas Hahn; Sebastian Sauppe; Michael Lell; Marc Kachelrieß
Show Abstract
Reduction of beam hardening artifacts in cone-beam CT imaging via SMART-RECON algorithm
Author(s): Yinsheng Li; John Garrett; Guang-Hong Chen
Show Abstract
Development of a realistic, dynamic digital brain phantom for CT perfusion validation
Author(s): Sarah E. Divel; W. Paul Segars; Soren Christensen; Max Wintermark; Maarten G. Lansberg; Norbert J. Pelc
Show Abstract
Fluence-field modulated x-ray CT using multiple aperture devices
Author(s): J. Webster Stayman; Aswin Mathews; Wojciech Zbijewski; Grace Gang; Jeffrey Siewerdsen; Satomi Kawamoto; Ira Blevis; Reuven Levinson
Show Abstract
Accuracy of patient specific organ-dose estimates obtained using an automated image segmentation algorithm
Author(s): Taly Gilat-Schmidt; Adam Wang; Thomas Coradi; Benjamin Haas; Josh Star-Lack
Show Abstract
Noise characteristics of CT perfusion imaging: how does noise propagate from source images to final perfusion maps?
Author(s): Ke Li; Guang-Hong Chen
Show Abstract
Experimental characterization of extra-focal radiation in CT scanners
Author(s): Bruce R. Whiting; Mariela A. Porras-Chaverri; Joshua D. Evans; Jeffrey F. Williamson
Show Abstract
Dual-source multi-energy CT with triple or quadruple x-ray beams
Author(s): Lifeng Yu; Zhoubo Li; Shuai Leng; Cynthia H. McCollough
Show Abstract
Optimized projection binning for improved helical amplitude- and phase-based 4DCT reconstruction in the presence of breathing irregularity
Author(s): René Werner; Christian Hofmann; Tobias Gauer
Show Abstract
Improving detector spatial resolution using pixelated scintillators with a barrier rib structure
Author(s): Langechuan Liu; Minghui Lu; Wanqing Cao; Luke Peng; Arthur Chen
Show Abstract
Solid-state flat panel imager with avalanche amorphous selenium
Author(s): James R. Scheuermann; Adrian Howansky; Amir H. Goldan; Olivier Tousignant; Sébastien Levéille; K. Tanioka; Wei Zhao
Show Abstract
A novel x-ray detector design with higher DQE and reduced aliasing: Theoretical analysis of x-ray reabsoprtion in detector converter material
Author(s): Tomi Nano; Terenz Escartin; Karim S. Karim; Ian A. Cunningham
Show Abstract
DQE simulation of a-Se x-ray detectors using ARTEMIS
Author(s): Yuan Fang; Aldo Badano
Show Abstract
High dynamic range CMOS-based mammography detector for FFDM and DBT
Author(s): Inge M. Peters; Chiel Smit; James J. Miller; Andrey Lomako
Show Abstract
An open library of CT patient projection data
Author(s): Baiyu Chen; Shuai Leng; Lifeng Yu; David Holmes; Joel Fletcher; Cynthia McCollough
Show Abstract
A generalized Fourier penalty in prior-image-based reconstruction for cross-platform imaging
Author(s): A. Pourmorteza; J. H. Siewerdsen; J. W. Stayman
Show Abstract
Limits to dose reduction from iterative reconstruction and the effect of through-slice blurring
Author(s): Scott S. Hsieh; Norbert J. Pelc
Show Abstract
Compensation of skull motion and breathing motion in CT using data-based and image-based metrics, respectively
Author(s): H. Bruder; C. Rohkohl; K. Stierstorfer; T. Flohr
Show Abstract
Reduction of truncation artifacts in CT images via a discriminative dictionary representation method
Author(s): Yang Chen; Ke Li; Yinsheng Li; Jiang Hsieh; Guang-Hong Chen
Show Abstract
Reduction of motion artifacts in cardiac CT based on partial angle reconstructions from short scan data
Author(s): Juliane Hahn; Herbert Bruder; Thomas Allmendinger; Karl Stierstorfer; Thomas Flohr; Marc Kachelriess
Show Abstract
Estimation of signal and noise for a whole-body photon counting research CT system
Author(s): Zhoubo Li; Shuai Leng; Zhicong Yu; Steffen Kappler; Cynthia H. McCollough
Show Abstract
Material decomposition and virtual non-contrast imaging in photon counting computed tomography: an animal study
Author(s): R. Gutjahr; C. Polster; S. Kappler; H. Pietsch; G. Jost; K. Hahn; F. Schöck; M. Sedlmair; T. Allmendinger; B. Schmidt; B. Krauss; T. G. Flohr
Show Abstract
On the analogy between pulse-pile-up in energy-sensitive, photon-counting detectors and level-crossing of shot noise
Author(s): Ewald Roessl; Matthias Bartels; Heiner Daerr; Roland Proksa
Show Abstract
Lossless compression of projection data from photon counting detectors
Author(s): Picha Shunhavanich; Norbert J. Pelc
Show Abstract
A high-resolution imaging technique using a whole-body, research photon counting detector CT system
Author(s): S. Leng; Z. Yu; A. Halaweish; S. Kappler; K. Hahn; A. Henning; Z. Li; J. Lane; D. L. Levin; S. Jorgensen; E. Ritman; C. McCollough
Show Abstract
Short term reproducibility of a high contrast 3-D isotropic optic nerve imaging sequence in healthy controls
Author(s): Robert L. Harrigan; Alex K. Smith; Louise A. Mawn; Seth A. Smith; Bennett A. Landman
Show Abstract
Crystal timing offset calibration method for time of flight PET scanners
Author(s): Jinghan Ye; Xiyun Song
Show Abstract
Solving outside-axial-field-of-view scatter correction problem in PET via digital experimentation
Author(s): Andriy Andreyev; Yang-Ming Zhu; Jinghan Ye; Xiyun Song; Zhiqiang Hu
Show Abstract
Initial experience in primal-dual optimization reconstruction from sparse-PET patient data
Author(s): Zheng Zhang; Jinghan Ye; Buxin Chen; Amy E. Perkins; Sean Rose; Emil Y. Sidky; Chien-Min Kao; Dan Xia; Chi-Hua Tung; Xiaochuan Pan
Show Abstract
Spatio-energetic cross-talks in photon counting detectors: detector model and correlated Poisson data generator
Author(s): Katsuyuki Taguchi; Christoph Polster; Okkyun Lee; Steffen Kappler
Show Abstract
Comparison of quantitative k-edge empirical estimators using an energy-resolved photon-counting detector
Author(s): Kevin C. Zimmerman; Taly Gilat Schmidt
Show Abstract
“Conventional” CT images from spectral measurements
Author(s): Paurakh L. Rajbhandary; Norbert J. Pelc
Show Abstract
Improving material decomposition by spectral optimization of photon counting computed tomography
Author(s): C. Polster; K. Hahn; R. Gutjahr; F. Schöck; S. Kappler; O. Dietrich; T. G. Flohr
Show Abstract
Optimal selection of thresholds for photon counting CT
Author(s): Thomas O'Donnell; Friederike Schoeck; Rabee Cheheltani; David Cormode; Zahi A. Fayad
Show Abstract
Method for dose-reduced 3D catheter tracking on a scanning-beam digital x-ray system using dynamic electronic collimation
Author(s): David A. P. Dunkerley; Tobias Funk; Michael A. Speidel
Show Abstract
Multi-gamma-source CT imaging system: a feasibility study with the Poisson noise
Author(s): Sunhee Wi; Seungryong Cho
Show Abstract
Investigation of noise and contrast sensitivity of an electron multiplying charge-coupled device (EMCCD) based cone beam micro-CT system
Author(s): Sumukh Bysani Krishnakumar; Alexander R. Podgorsak; S. V. Setlur Nagesh; Amit Jain; Stephen Rudin; Daniel R. Bednarek; Ciprian N. Ionita
Show Abstract
High-spatial-resolution nanoparticle x-ray fluorescence tomography
Author(s): Jakob C. Larsson; William Vågberg; Carmen Vogt; Ulf Lundström; Daniel H. Larsson; Hans M. Hertz
Show Abstract
800-MeV magnetic-focused flash proton radiography for high-contrast imaging of low-density biologically-relevant targets using an inverse-scatter collimator
Author(s): Matthew S. Freeman; Jason Allison; Camilo Espinoza; John Jerome Goett; Gary Hogan; Brian Hollander; Kris Kwiatkowski; Julian Lopez; Fesseha Mariam; Michael Martinez; Jason Medina; Patrick Medina; Frank E. Merrill; Deborah Morley; Chris Morris; Matthew Murray; Paul Nedrow; Alexander Saunders; Tamsen Schurman; Thomas Sisneros; Amy Tainter; Frans Trouw; Dale Tupa; Josh Tybo; Carl Wilde
Show Abstract
Method to study sample object size limit of small-angle x-ray scattering computed tomography
Author(s): Mina Choi; Bahaa Ghammraoui; Andreu Badal; Aldo Badano
Show Abstract
Coded aperture x-ray diffraction imaging with transmission computed tomography side-information
Author(s): Ikenna Odinaka; Joel A. Greenberg; Yan Kaganovsky; Andrew Holmgren; Mehadi Hassan; David G. Politte; Joseph A. O'Sullivan; Lawrence Carin; David J. Brady
Show Abstract
Coded aperture coherent scatter imaging for breast cancer detection: a Monte Carlo evaluation
Author(s): Manu N. Lakshmanan; Robert E. Morris; Joel A. Greenberg; Ehsan Samei; Anuj J. Kapadia
Show Abstract
Task-driven tube current modulation and regularization design in computed tomography with penalized-likelihood reconstruction
Author(s): G. J. Gang; J. H. Siewerdsen; J. W. Stayman
Show Abstract
Design, fabrication, and implementation of voxel-based 3D printed textured phantoms for task-based image quality assessment in CT
Author(s): Justin Solomon; Alexandre Ba; Andrew Diao; Joseph Lo; Elianna Bier; François Bochud; Michael Gehm; Ehsan Samei
Show Abstract
Detectable change of lung nodule volume with CT in a phantom study with high and low signal to background contrast
Author(s): Marios A. Gavrielides; Qin Li; Rongping Zeng; Qi Gong; Kyle Myers; Berkman Sahiner; Nicholas Petrick
Show Abstract
Investigation of optimal parameters for penalized maximum-likelihood reconstruction applied to iodinated contrast-enhanced breast CT
Author(s): Andrey Makeev; Lynda Ikejimba; Joseph Y. Lo; Stephen J. Glick
Show Abstract
Predicting detection performance with model observers: Fourier domain or spatial domain?
Author(s): Baiyu Chen; Lifeng Yu; Shuai Leng; James Kofler; Christopher Favazza; Thomas Vrieze; Cynthia McCollough
Show Abstract
Comparison of model and human observer performance in FFDM, DBT, and synthetic mammography
Author(s): Lynda Ikejimba; Stephen J. Glick; Ehsan Samei; Joseph Y. Lo
Show Abstract
Conceptual detector development and Monte Carlo simulation of a novel 3D breast computed tomography system
Author(s): Jens Ziegle; Bernhard H. Müller; Bernd Neumann; Christoph Hoeschen
Show Abstract
Eigenbreasts for statistical breast phantoms
Author(s): Gregory M. Sturgeon; Daniel J. Tward; M. Ketcha; J. T. Ratnanather; M. I. Miller; Subok Park; W. P. Segars; Joseph Y. Lo
Show Abstract
Optimal exposure techniques for iodinated contrast enhanced breast CT
Author(s): Stephen J. Glick; Andrey Makeev
Show Abstract
Simulation of spiculated breast lesions
Author(s): Premkumar Elangovan; Faisal Alrehily; R. Ferrari Pinto; Alaleh Rashidnasab; David R. Dance; Kenneth C. Young; Kevin Wells
Show Abstract
Estimation of mammary gland composition using CdTe series detector developed for photon-counting mammography
Author(s): Akiko Ihori; Chizuru Okamoto; Tsutomu Yamakawa; Shuichiro Yamamoto; Masahiro Okada; Ai Nakajima; Misa Kato; Yoshie Kodera
Show Abstract
Reduction of artifacts in computer simulation of breast Cooper's ligaments
Author(s): David D. Pokrajac; Adam Kuperavage; Andrew D. A. Maidment; Predrag R. Bakic
Show Abstract
Analysis of the scatter effect on detective quantum efficiency of digital mammography
Author(s): Jiwoong Park; Seungman Yun; Dong Woon Kim; Cheol-Ha Baek; Hanbean Youn; Hosang Jeon; Ho Kyung Kim
Show Abstract
Comparison of contrast enhancement methods using photon counting detector in spectral mammography
Author(s): Hyemi Kim; Su-Jin Park; Byungdu Jo; Dohyeon Kim; Hee-Joung Kim
Show Abstract
Biopsy system guided by positron emission tomography in real-time
Author(s): L. Moliner; J. Álamo; D. Hellingman; J. L. Peris; J. Gomez; P. Tattersall; V. Carrilero; A. Orero; C. Correcher; J. M. Benlloch
Show Abstract
Discrimination between normal breast tissue and tumor tissue using CdTe series detector developed for photon-counting mammography
Author(s): Chizuru Okamoto; Akiko Ihori; Tsutomu Yamakawa; Shuichiro Yamamoto; Masahiro Okada; Misa Kato; Ai Nakajima; Yoshie Kodera
Show Abstract
Grid-less imaging with antiscatter correction software in 2D mammography: the effects on image quality and MGD under a partial virtual clinical validation study
Author(s): Nelis Van Peteghem; Frédéric Bemelmans; Xenia Bramaje Adversalo; Elena Salvagnini; Nicholas Marshall; Hilde Bosmans; Chantal Van Ongeval
Show Abstract
Estimation of adipose compartment volumes in CT images of a mastectomy specimen
Author(s): Abdullah-Al-Zubaer Imran; David D. Pokrajac; Andrew D. A. Maidment; Predrag R. Bakic
Show Abstract
Feasibility of generating quantitative composition images in dual energy mammography: a simulation study
Author(s): Donghoon Lee; Ye-seul Kim; Sunghoon Choi; Haenghwa Lee; Seungyeon Choi; Hee-Joung Kim
Show Abstract
A new paradigm of dielectric relaxation spectroscopy for non-invasive detection of breast abnormalities: a preliminary feasibility analysis
Author(s): Sreeram Dhurjaty; Yuchen Qiu; Maxine Tan; Wei Qian; Bin Zheng
Show Abstract
DICOM organ dose does not accurately represent calculated dose in mammography
Author(s): Moayyad E. Suleiman; Patrick C. Brennan; Mark F. McEntee
Show Abstract
Radiation dose differences between digital mammography and digital breast tomosynthesis are dependent on breast thickness
Author(s): Maram M. Alakhras; Claudia Mello-Thoms; Roger Bourne; Mary Rickard; Jennifer Diffey; Patrick C. Brennan
Show Abstract
Ring artifacts removal via spatial sparse representation in cone beam CT
Author(s): Zhongyuan Li; Guang Li; Yi Sun; Shouhua Luo
Show Abstract
Library-based scatter correction for dedicated cone beam breast CT: a feasibility study
Author(s): Linxi Shi; Srinivasan Vedantham; Andrew Karellas; Lei Zhu
Show Abstract
Properties of the ellipse-line-ellipse trajectory with asymmetrical variations
Author(s): Zijia Guo; Frédéric Noo; Andreas Maier; Guenter Lauritsch
Show Abstract
Lens of the eye dose calculation for neuro-interventional procedures and CBCT scans of the head
Author(s): Zhenyu Xiong; Sarath Vijayan; Vijay Rana; Amit Jain; Stephen Rudin; Daniel R. Bednarek
Show Abstract
A system to track skin dose for neuro-interventional cone-beam computed tomography (CBCT)
Author(s): Sarath Vijayan; Zhenyu Xiong; Stephen Rudin; Daniel R. Bednarek
Show Abstract
Regularization design for high-quality cone-beam CT of intracranial hemorrhage using statistical reconstruction
Author(s): H. Dang; J. W. Stayman; J. Xu; A. Sisniega; W. Zbijewski; X. Wang; D. H. Foos; N. Aygun; V. E. Koliatsos; J. H. Siewerdsen
Show Abstract
A fast GPU-based approach to branchless distance-driven projection and back-projection in cone beam CT
Author(s): Daniel Schlifske; Henry Medeiros
Show Abstract
Scatter correction in CBCT with an offset detector through a deconvolution method using data consistency
Author(s): Changhwan Kim; Miran Park; Hoyeon Lee; Seungryong Cho
Show Abstract
Imaging characteristics of distance-driven method in a prototype cone-beam computed tomography (CBCT)
Author(s): Sunghoon Choi; Ye-seul Kim; Haenghwa Lee; Donghoon Lee; Chang-Woo Seo; Hee-Joung Kim
Show Abstract
Deblurring in iterative reconstruction of half CBCT for image guided brain radiosurgery
Author(s): SayedMasoud Hashemi; Young Lee; Markus Eriksson; Håkan Nordström; Bongyong Song; Wooseok Nam; Arjun Sahgal; William Song; Mark Ruschin
Show Abstract
Algorithm for x-ray beam hardening and scatter correction in low-dose cone-beam CT: phantom studies
Author(s): Wenlei Liu; Junyan Rong; Peng Gao; Qimei Liao; HongBing Lu
Show Abstract
Beam hardening and motion artifacts in cardiac CT: evaluation and iterative correction method
Author(s): Zeyang Shen; Okkyun Lee; Katsuyuki Taguchi
Show Abstract
MADR: metal artifact detection and reduction
Author(s): Sunil Prasad Jaiswal; Sungsoo Ha; Klaus Mueller
Show Abstract
Metal artifact reduction in CT via ray profile correction
Author(s): Sungsoo Ha; Klaus Mueller
Show Abstract
Line-ratio based ring artifact correction method using transfer function
Author(s): Daejoong Oh; Dosik Hwang; Younguk Kim
Show Abstract
A geometric calibration method for inverse geometry computed tomography using P-matrices
Author(s): Jordan M. Slagowski; David A. P. Dunkerley; Charles R. Hatt; Michael A. Speidel
Show Abstract
CT dose minimization using personalized protocol optimization and aggressive bowtie
Author(s): Hui Wang; Zhye Yin; Yannan Jin; Mingye Wu; Yangyang Yao; Kun Tao; Mannudeep K. Kalra; Bruno De Man
Show Abstract
Segmentation-free x-ray energy spectrum estimation for computed tomography
Author(s): Wei Zhao; Qiude Zhang; Tianye Niu
Show Abstract
Noise power spectrum studies of CT systems with off-centered image object and bowtie filter
Author(s): Daniel Gomez-Cardona; Juan P. Cruz-Bastida; Ke Li; Adam Budde; Jiang Hsieh; Guang-Hong Chen
Show Abstract
Prototype adaptive bow-tie filter based on spatial exposure time modulation
Author(s): Andreu Badal
Show Abstract
Estimation of breast dose saving potential using a breast positioning technique for organ-based tube current modulated CT
Author(s): Wanyi Fu; Xiaoyu Tian; Gregory Sturgeon; Greeshma Agasthya; William Paul Segars; Mitchell M. Goodsitt; Ella A. Kazerooni; Ehsan Samei
Show Abstract
Robust dynamic myocardial perfusion CT deconvolution using adaptive-weighted tensor total variation regularization
Author(s): Changfei Gong; Dong Zeng; Zhaoying Bian; Jing Huang; Xinyu Zhang; Hua Zhang; Lijun Lu; Qianjin Feng; Zhengrong Liang; Jianhua Ma
Show Abstract
Organ dose conversion coefficients for tube current modulated CT protocols for an adult population
Author(s): Wanyi Fu; Xiaoyu Tian; Pooyan Sahbaee; Yakun Zhang; William Paul Segars; Ehsan Samei
Show Abstract
A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging
Author(s): Pooyan Sahbaee; Ehsan Abadi; Jeremiah Sanders; Marc Becchetti; Yakun Zhang; Greeshma Agasthya; Paul Segars; Ehsan Samei
Show Abstract
Experimental demonstration of a dynamic bowtie for region-based CT fluence optimization
Author(s): Vance Robinson; Walt Smith; Xue Rui; Zhye Yin; Mingye Wu; Paul Fitzgerald; Bruno De Man
Show Abstract
Hybrid deterministic and stochastic x-ray transport simulation for transmission computed tomography with advanced detector noise model
Author(s): Lucretiu M. Popescu
Show Abstract
An automated technique for estimating patient-specific regional imparted energy and dose in TCM CT exams
Author(s): Jeremiah W. Sanders; Xiaoyu Tian; W. Paul Segars; John Boone; Ehsan Samei
Show Abstract
A framework for analytical estimation of patient-specific CT dose
Author(s): Hanbean Youn; Jin Woo Kim; Hosang Jeon; Jiho Nam; Seungman Yun; Min Kook Cho; Ho Kyung Kim
Show Abstract
Modulation transfer function determination using the edge technique for cone-beam micro-CT
Author(s): Junyan Rong; Wenlei Liu; Peng Gao; Qimei Liao; Hongbing Lu
Show Abstract
An approach for quantitative image quality analysis for CT
Author(s): Amir Rahimi; Joe Cochran; Doug Mooney; Joe Regensburger
Show Abstract
Quantitative comparison using generalized relative object detectability (G-ROD) metrics of an amorphous selenium detector with high resolution microangiographic fluoroscopes (MAF) and standard flat panel detectors (FPD)
Author(s): M. Russ; A. Shankar; A. Jain; S. V. Setlur Nagesh; C. N. Ionita; C. Scott; K. S. Karim; D. R. Bednarek; S. Rudin
Show Abstract
Exploration of maximum count rate capabilities for large-area photon counting arrays based on polycrystalline silicon thin-film transistors
Author(s): Albert K. Liang; Martin Koniczek; Larry E. Antonuk; Youcef El-Mohri; Qihua Zhao
Show Abstract
Indirect-detection single-photon-counting x-ray detector for breast tomosynthesis
Author(s): Hao Jiang; Joerg Kaercher; Roger Durst
Show Abstract
SWAD: inherent photon counting performance of amorphous selenium multi-well avalanche detector
Author(s): Jann Stavro; Amir H. Goldan; Wei Zhao
Show Abstract
Focal spot deblurring for high resolution direct conversion x-ray detectors
Author(s): S. V. Setlur Nagesh; R. Rana; M. Russ; Ciprian N. Ionita; D. R. Bednarek; S. Rudin
Show Abstract
Noise power spectrum measurements under nonuniform gains and their compensations
Author(s): Dong Sik Kim; Eun Kim; Choul Woo Shin
Show Abstract
A comparison of quantum limited dose and noise equivalent dose
Author(s): Isaias D. Job; Sarah J. Boyce; Michael J. Petrillo; Kungang Zhou
Show Abstract
Optimizing the CsI thickness for chest dual-shot dual-energy detectors
Author(s): Dong Woon Kim; Junwoo Kim; Hanbean Youn; Hosang Jeon; Ho Kyung Kim
Show Abstract
Physical properties of a new flat panel detector with cesium-iodide technology
Author(s): Andreas Hahn; Petar Penchev; Martin Fiebich
Show Abstract
Detective quantum efficiency: a standard test to ensure optimal detector performance and low patient exposures
Author(s): Terenz R. Escartin; Tomi F. Nano; Ian A. Cunningham
Show Abstract
MTF and NPS of single-shot dual-energy sandwich detectors
Author(s): Junwoo Kim; Dong Woon Kim; Hanbean Yun; Ho Kyung Kim
Show Abstract
Computed tomography with single-shot dual-energy sandwich detectors
Author(s): Seung Ho Kim; Hanbean Youn; Daecheon Kim; Dong Woon Kim; Hosang Jeon; Ho Kyung Kim
Show Abstract
Theoretical and Monte Carlo optimization of a stacked three-layer flat-panel x-ray imager for applications in multi-spectral diagnostic medical imaging
Author(s): Sebastian Lopez Maurino; Aldo Badano; Ian A. Cunningham; Karim S. Karim
Show Abstract
Noise suppression for energy-resolved CT using similarity-based non-local filtration
Author(s): Joe Harms; Tonghe Wang; Michael Petrongolo; Lei Zhu
Show Abstract
Dual energy x-ray imaging and scoring of coronary calcium: physics-based digital phantom and clinical studies
Author(s): Bo Zhou; Di Wen; Katelyn Nye; Robert C. Gilkeson; David L. Wilson
Show Abstract
Enhanced diagnostic value for coronary CT angiography of calcified coronary arteries using dual energy and a novel high-Z contrast material: a phantom study
Author(s): Jack W. Lambert; Karen G. Ordovas; Yuxin Sun; Benjamin M. Yeh
Show Abstract
Reconstruction of limited-angle dual-energy CT using mutual learning and cross-estimation (MLCE)
Author(s): Huayu Zhang; Yuxiang Xing
Show Abstract
Calcium scoring with dual-energy CT in men and women: an anthropomorphic phantom study
Author(s): Qin Li; Songtao Liu; Kyle Myers; Marios A. Gavrielides; Rongping Zeng; Berkman Sahiner; Nicholas Petrick
Show Abstract
Dual-energy computed tomography of the head: a phantom study assessing axial dose distribution, eye lens dose, and image noise level
Author(s): Kosuke Matsubara; Hiroki Kawashima; Takashi Hamaguchi; Tadanori Takata; Masanao Kobayashi; Katsuhiro Ichikawa; Kichiro Koshida
Show Abstract
Multi-energy method of digital radiography for imaging of biological objects
Author(s): V. D. Ryzhikov; S. V. Naydenov; O. D. Opolonin; V. G. Volkov; C. F. Smith
Show Abstract
Iterative image reconstruction for multienergy computed tomography via structure tensor total variation regularization
Author(s): Dong Zeng; Zhaoying Bian; Changfei Gong; Jing Huang; Ji He; Hua Zhang; Lijun Lu; Qianjin Feng; Zhengrong Liang; Jianhua Ma
Show Abstract
Iterative CT reconstruction using coordinate descent with ordered subsets of data
Author(s): F. Noo; K. Hahn; H. Schöndube; K. Stierstorfer
Show Abstract
Optimization-based reconstruction for reduction of CBCT artifact in IGRT
Author(s): Dan Xia; Zheng Zhang; Pascal Paysan; Dieter Seghers; Marcus Brehm; Peter Munro; Emil Y. Sidky; Charles Pelizzari; Xiaochuan Pan
Show Abstract
Resolution-enhancing hybrid, spectral CT reconstruction
Author(s): D. P. Clark; C. T. Badea
Show Abstract
Axial 3D region of interest reconstruction using weighted cone beam BPF/DBPF algorithm cascaded with adequately oriented orthogonal butterfly filtering
Author(s): Shaojie Tang; Xiangyang Tang
Show Abstract
Joint regularization for spectro-temporal CT reconstruction
Author(s): D. P. Clark; C. T. Badea
Show Abstract
Texture-preserved penalized weighted least-squares reconstruction of low-dose CT image via image segmentation and high-order MRF modeling
Author(s): Hao Han; Hao Zhang; Xinzhou Wei; William Moore; Zhengrong Liang
Show Abstract
Regularized CT reconstruction on unstructured grid
Author(s): Yun Chen; Yao Lu; Xiangyuan Ma; Yuesheng Xu
Show Abstract
A new look at signal sparsity paradigm for low-dose computed tomography image reconstruction
Author(s): Yan Liu; Hao Zhang; William Moore; Zhengrong Liang
Show Abstract
Texture-preserving Bayesian image reconstruction for low-dose CT
Author(s): Hao Zhang; Hao Han; Yifan Hu; Yan Liu; Jianhua Ma; Lihong Li; William Moore; Zhengrong Liang
Show Abstract
Fast conjugate gradient algorithm extension for analyzer-based imaging reconstruction
Author(s): Oriol Caudevilla; Jovan G. Brankov
Show Abstract
Efficient iterative image reconstruction algorithm for dedicated breast CT
Author(s): Natalia Antropova; Adrian Sanchez; Ingrid S. Reiser; Emil Y. Sidky; John Boone; Xiaochuan Pan
Show Abstract
Direct reconstruction of enhanced signal in computed tomography perfusion
Author(s): Bin Li; Qingwen Lyu; Jianhua Ma; Jing Wang
Show Abstract
A method for investigating system matrix properties in optimization-based CT reconstruction
Author(s): Sean D. Rose; Emil Y. Sidky; Xiaochuan Pan
Show Abstract
A comparative study of the effects of using normalized patches for penalized likelihood tomographic reconstruction
Author(s): Xue Ren; Soo-Jin Lee
Show Abstract
High-resolution and large-volume tomography reconstruction for x-ray microscopy
Author(s): Chang-Chieh Cheng; Yeukuang Hwu; Yu-Tai Ching
Show Abstract
An adaptive method for weighted median priors in transmission tomography reconstruction
Author(s): Ji Eun Jung; Soo-Jin Lee
Show Abstract
Continuous analog of multiplicative algebraic reconstruction technique for computed tomography
Author(s): Kiyoko Tateishi; Yusaku Yamaguchi; Omar M. Abou Al-Ola; Takeshi Kojima; Tetsuya Yoshinaga
Show Abstract
Texture enhanced optimization-based image reconstruction (TxE-OBIR) from sparse projection views
Author(s): Huiqiao Xie; Tianye Niu; Yi Yang; Yi Ren; Xiangyang Tang
Show Abstract
Acceleration of iterative tomographic image reconstruction by reference-based back projection
Author(s): Chang-Chieh Cheng; Ping-Hui Li; Yu-Tai Ching
Show Abstract
Noise reduction in computed tomography using a multiplicative continuous-time image reconstruction method
Author(s): Yusaku Yamaguchi; Takeshi Kojima; Tetsuya Yoshinaga
Show Abstract
Assessment of tomographic reconstruction performance using the Mojette transform
Author(s): Henri Der Sarkissian; Jeanpierre Guédon; Benoit Recur; Nicolas Normand
Show Abstract
A wide-acceptance Compton spectrometer for spectral characterization of a medical x-ray source
Author(s): Michelle A. Espy; A. Gehring; A. Belian; T. Haines; J. Hunter; M. James; M. Klasky; J. Mendez; D. Moir; R. Sedillo; R. Shurter; J. Stearns; K. Van Syoc; P. Volegov
Show Abstract
X-ray spectrum estimation from transmission measurements by an exponential of a polynomial model
Author(s): Boris Perkhounkov; Jessika Stec; Emil Y. Sidky; Xiaochuan Pan
Show Abstract
A dual-energy medical instrument for measurement of x-ray source voltage and dose rate
Author(s): V. D. Ryzhikov; S. V. Naydenov; V. G. Volkov; O. D. Opolonin; S. Makhota; T. Pochet; C. F. Smith
Show Abstract
In vivo small animal lung speckle imaging with a benchtop in-line XPC system
Author(s): A. B. Garson; S. Gunsten; S. Vasireddi; S. Brody; M. A. Anastasio
Show Abstract
Seventh-generation CT
Author(s): G. M. Besson
Show Abstract
A glass-sealed field emission x-ray tube based on carbon nanotube emitter for medical imaging
Author(s): Seung Jun Yeo; Jaeik Jeong; Jeung Sun Ahn; Hunkuk Park; Junghwan Kwak; Eunkyong Noh; Sanghyun Paik; Seung Hoon Kim; Jehwang Ryu
Show Abstract
Organ radiation exposure with EOS: GATE simulations versus TLD measurements
Author(s): A. H. Clavel; P. Thevenard-Berger; F. R. Verdun; J. M. Létang; A. Darbon
Show Abstract
Scattering-compensated cone beam x-ray luminescence computed tomography
Author(s): Peng Gao; Junyan Rong; Huangsheng Pu; Wenlei Liu; Qimei Liao; Hongbing Lu
Show Abstract
Microstructure analysis of the pulmonary acinus by a synchrotron radiation CT
Author(s): K. Minami; K. Maeda; Y. Kawata; N. Niki; K. Umetani; Y. Nakano; H. Sakai; H. Ohmatsu; H. Itoh
Show Abstract
Ultrasound waveform tomography with the second-order total-generalized-variation regularization
Author(s): Youzuo Lin; Lianjie Huang
Show Abstract
Event-by-event PET image reconstruction using list-mode origin ensembles algorithm
Author(s): Andriy Andreyev
Show Abstract
Quantitative analysis of L-SPECT system for small animal brain imaging
Author(s): Tasneem Rahman; Murat Tahtali; Mark R. Pickering
Show Abstract
In vitro flow assessment: from PC-MRI to computational fluid dynamics including fluid-structure interaction
Author(s): Jonas Kratzke; Fabian Rengier; Christian Weis; Carsten J. Beller; Vincent Heuveline
Show Abstract
Characterization of various tissue mimicking materials for medical ultrasound imaging
Author(s): Audrey Thouvenot; Tamie Poepping; Terry M. Peters; Elvis C. S. Chen
Show Abstract
Quantitative evaluation of susceptibility effects caused by dental materials in head magnetic resonance imaging
Author(s): S. Strocchi; M. Ghielmi; F. Basilico; A. Macchi; R. Novario; R. Ferretti; E. Binaghi
Show Abstract
Effects of tissue heterogeneity on single-coil, scanning MIT imaging
Author(s): J. R. Feldkamp; S. Quirk
Show Abstract
Quantitative evaluation of PET image using event information bootstrap
Author(s): Hankyeol Song; Shin Hye Kwak; Kyeong Min Kim; Joo Hyun Kang; Yong Hyun Chung; Sang-Keun Woo
Show Abstract
Construction and evaluation of a high-energy grating-based x-ray phase-contrast imaging setup
Author(s): Christian Hauke; Florian Horn; Georg Pelzer; Jens Rieger; Sebastian Lachner; Veronika Ludwig; Maria Seifert; Max Schuster; Johannes Wandner; Andreas Wolf; Thomas Weber; Thilo Michel; Gisela Anton
Show Abstract
Feasibility of using energy-resolving detectors in differential phase-contrast imaging
Author(s): Pavlo Baturin
Show Abstract
Joint reconstruction of absorption and refractive properties in propagation-based x-ray phase-contrast tomography via a non-linear image reconstruction algorithm
Author(s): Yujia Chen; Kun Wang; Doga Gursoy; Carmen Soriano; Francesco De Carlo; Mark A. Anastasio
Show Abstract
Improvement of the visibility for x-ray phase contrast imaging using photon counting detector
Author(s): S. Sano; K. Tanabe; T. Yoshimuta; K. Kimura; T. Shirai; T. Doki; A. Horiba; T. Sato
Show Abstract
Quantification of signal detection performance degradation induced by phase-retrieval in propagation-based x-ray phase-contrast imaging
Author(s): Cheng-Ying Chou; Mark A. Anastasio
Show Abstract
Quantitative imaging of the microbubble concentrations by using an in-line phase contrast tomosynthesis prototype: a preliminary phantom study
Author(s): Di Wu; Muhammad U. Ghani; Molly D. Wong; Yuhua Li; Kai Yang; Wei R. Chen; Bin Zheng; Hong Liu
Show Abstract
Evaluation of a new reconstruction algorithm for x-ray phase-contrast imaging
Author(s): Maria Seifert; Christian Hauke; Florian Horn; Sebastian Lachner; Veronika Ludwig; Georg Pelzer; Jens Rieger; Max Schuster; Johannes Wandner; Andreas Wolf; Thilo Michel; Gisela Anton
Show Abstract
Photon counting CT of the liver with dual-contrast enhancement
Author(s): Daniela Muenzel; Roland Proksa; Heiner Daerr; Alexander A. Fingerle; Franz Pfeiffer; Ernst J. Rummeny; Peter B. Noël
Show Abstract
Low-dose performance of a whole-body research photon-counting CT scanner
Author(s): Zhicong Yu; Shuai Leng; Steffen Kappler; Katharina Hahn; Zhoubo Li; Ahmed F. Halaweish; Andre Henning; Erik L. Ritman; Cynthia H. McCollough
Show Abstract
Novel approaches to address spectral distortions in photon counting x-ray CT using artificial neural networks
Author(s): M. Touch; D. P. Clark; W. Barber; C. T. Badea
Show Abstract
Feasibility study of sparse-angular sampling and sinogram interpolation in material decomposition with a photon-counting detector
Author(s): Dohyeon Kim; Byungdu Jo; Su-Jin Park; Hyemi Kim; Hee-Joung Kim
Show Abstract
Spot scanning proton therapy plan assessment: design and development of a dose verification application for use in routine clinical practice
Author(s): Kurt E. Augustine; Timothy J. Walsh; Chris J. Beltran; Joshua B. Stoker; Daniel W. Mundy; Mark D. Parry; Martin Bues; Mirek Fatyga
Show Abstract
Estimation of the influence of radical effect in the proton beams using a combined approach with physical data and gel data
Author(s): K. Haneda
Show Abstract
Validation of coded aperture coherent scatter spectral imaging for normal and neoplastic breast tissues via surgical pathology
Author(s): R. E. Morris; K. E. Albanese; M. N. Lakshmanan; S. J. McCall; J. A. Greenberg; A. J. Kapadia
Show Abstract
Development of a Hausdorff distance based 3D quantification technique to evaluate the CT imaging system impact on depiction of lesion morphology
Author(s): Pooyan Sahbaee; Marthony Robins; Justin Solomon; Ehsan Samei
Show Abstract
Second generation anthropomorphic physical phantom for mammography and DBT: Incorporating voxelized 3D printing and inkjet printing of iodinated lesion inserts
Author(s): Dhiraj Sikaria; Stephanie Musinsky; Gregory M. Sturgeon; Justin Solomon; Andrew Diao; Michael E. Gehm; Ehsan Samei; Stephen J. Glick; Joseph Y. Lo
Show Abstract
Evaluation of a projection-domain lung nodule insertion technique in thoracic CT
Author(s): Chi Ma; Baiyu Chen; Chi Wan Koo; Edwin A. Takahashi; Joel G. Fletcher; Cynthia H. McCollough; David L. Levin; Ronald S. Kuzo; Lyndsay D. Viers; Stephanie A. Vincent Sheldon; Shuai Leng; Lifeng Yu
Show Abstract
Synthesized interstitial lung texture for use in anthropomorphic computational phantoms
Author(s): Marc F. Becchetti; Justin B. Solomon; W. Paul Segars; Ehsan Samei
Show Abstract
Development and comparison of projection and image space 3D nodule insertion techniques
Author(s): Marthony Robins; Justin Solomon; Pooyan Sahbaee; Ehsan Samei
Show Abstract
kV x-ray dual digital tomosynthesis for image guided lung SBRT
Author(s): Larry Partain; Douglas Boyd; Namho Kim; Andrew Hernandez; Megan Daly; John Boone
Show Abstract
Design, optimization and evaluation of a “smart” pixel sensor array for low-dose digital radiography
Author(s): Kai Wang; Xinghui Liu; Hai Ou; Jun Chen
Show Abstract
Modeling acquisition geometries with improved super-resolution in digital breast tomosynthesis
Author(s): Raymond J. Acciavatti; E. Paul Wileyto; Andrew D. A. Maidment
Show Abstract
Scatter estimation and removal of anti-scatter grid-line artifacts from anthropomorphic head phantom images taken with a high resolution image detector
Author(s): R. Rana; A. Jain; A. Shankar; D. R. Bednarek; S. Rudin
Show Abstract
Optical geometry calibration method for free-form digital tomosynthesis
Author(s): Pavel Chtcheprov; Allison Hartman; Jing Shan; Yueh Z. Lee; Otto Zhou; Jianping Lu
Show Abstract
Initial clinical evaluation of stationary digital chest tomosynthesis
Author(s): Allison E. Hartman; Jing Shan; Gongting Wu; Yueh Z. Lee; Otto Zhou; Jianping Lu; Michael Heath; Xiaohui Wang; David Foos
Show Abstract
Anatomical decomposition in dual energy chest digital tomosynthesis
Author(s): Donghoon Lee; Ye-seul Kim; Sunghoon Choi; Haenghwa Lee; Seungyeon Choi; Hee-Joung Kim
Show Abstract
Optimization of exposure parameters in digital tomosynthesis considering effective dose and image quality
Author(s): Seungyeon Choi; Sunghoon Choi; Ye-seul Kim; Haenghwa Lee; Donghoon Lee; Pil-Hyun Jeon; Dong-Hyuk Jang; Hee-Joung Kim
Show Abstract
Digital breast tomosynthesis reconstruction using spatially weighted non-convex regularization
Author(s): Jiabei Zheng; Jeffrey A. Fessler; Heang-Ping Chan
Show Abstract
Optimal kVp in chest computed radiography using visual grading scores: a comparison between visual grading characteristics and ordinal regression analysis
Author(s): Xiaoming Zheng; Myeongsoo Kim; Sook Yang
Show Abstract
On the properties of artificial neural network filters for bone-suppressed digital radiography
Author(s): Eunpyeong Park; Junbeom Park; Daecheon Kim; Hanbean Youn; Hosang Jeon; Jin Sung Kim; Dong-Joong Kang; Ho Kyung Kim
Show Abstract
Effects of angular range on image quality of chest digital tomosynthesis
Author(s): Haenghwa Lee; Ye-seul Kim; Sunghoon Choi; Dong-Hoon Lee; Seungyeon Choi; Hee-Joung Kim
Show Abstract
Quantitative comparison of spatial resolution in step-and-shoot and continuous motion digital breast tomosynthesis
Author(s): Muhammad U. Ghani; Di Wu; Molly D. Wong; Liqiang Ren; Bin Zheng; Kai Yang; Xizeng Wu; Hong Liu
Show Abstract
C-arm technique using distance driven method for nephrolithiasis and kidney stones detection
Author(s): Nuhad Malalla; Pengfei Sun; Ying Chen; Michael E. Lipkin; Glenn M. Preminger; Jun Qin
Show Abstract
Ray tracing reconstruction investigation for C-arm tomosynthesis
Author(s): Nuhad A. Y. Malalla; Ying Chen
Show Abstract
Integration of kerma-area product and cumulative air kerma determination into a skin dose tracking system for fluoroscopic imaging procedures
Author(s): Sarath Vijayan; Alok Shankar; Stephen Rudin; Daniel R. Bednarek
Show Abstract
Low dose CT perfusion using k-means clustering
Author(s): Francesco Pisana; Thomas Henzler; Stefan Schönberg; Ernst Klotz; Bernhard Schmidt; Marc Kachelrieß
Show Abstract
The evolution of medical imaging from qualitative to quantitative: opportunities, challenges, and approaches (Conference Presentation)
Author(s): Edward F. Jackson
Show Abstract

© SPIE. Terms of Use
Back to Top