Share Email Print
cover

PROCEEDINGS VOLUME 8213

Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XVI
For the purchase of this volume in printed format, please visit Proceedings.com

Volume Details

Volume Number: 8213
Date Published: 8 March 2012

Table of Contents
show all abstracts | hide all abstracts
Front Matter: Volume 8213
Author(s): Proceedings of SPIE
In vivo human retinal and choroidal vasculature visualization using differential phase contrast swept source optical coherence tomography at 1060 nm
Author(s): Reza Motaghiannezam; Scott Fraser
Show Abstract
Angiogram visualization and total velocity blood flow assessment based on intensity information analysis of OCT data
Author(s): Daniel Ruminski; Danuta Bukowska; Iwona Gorczynska; Maciej Szkulmowski; Maciej Wojtkowski
Show Abstract
Visualization of human retinal capillary networks: a comparison of intensity, speckle-variance and phase-variance optical coherence tomography
Author(s): Dae Yu Kim; Jeff Fingler; John S. Werner; Daniel M. Schwartz; Scott E. Fraser; Robert J. Zawadzki
Show Abstract
Prenatal imaging of distal limb abnormalities using OCT in mice
Author(s): Irina V. Larina; Saba H. Syed; Mary E. Dickinson; Paul Overbeek; Kirill V. Larin
Show Abstract
Assessment of collagen changes in ovarian tissue by extracting optical scattering coefficient from OCT images
Author(s): Yi Yang; Tianheng Wang; Nrusingh Biswal; Xiaohong Wang; Melinda Sanders; Molly Brewer; Quing Zhu
Show Abstract
Fourier domain OCT imaging of American cockroach nervous system
Author(s): Joanna Wyszkowska; Iwona Gorczynska; Daniel Ruminski; Karol Karnowski; Andrzej Kowalczyk; Maria Stankiewicz; Maciej Wojtkowski
Show Abstract
Visible light optical coherence tomography for in vivo imaging the spectral contrasts of the retinal nerve fiber layer
Author(s): Xiangyang Zhang; Jianming Hu; Robert W. Knighton; Xiang-Run Huang; Carmen A. Puliafito; Shuliang Jiao
Show Abstract
Adaptive optics: optical coherence tomography system for in-vivo imaging of the mouse retina
Author(s): Yifan Jian; Ali Issaei; Robert J. Zawadzki; Marinko V. Sarunic
Show Abstract
MEMS tunable VCSEL light source for ultrahigh speed 60kHz - 1MHz axial scan rate and long range centimeter class OCT imaging
Author(s): Benjamin Potsaid; Vijaysekhar Jayaraman; James G. Fujimoto; James Jiang; Peter J. S. Heim; Alex E. Cable
Show Abstract
Coherence length extension of Fourier domain mode locked lasers
Author(s): Desmond C. Adler; Wolfgang Wieser; Francois Trepanier; Joseph M. Schmitt; Robert A. Huber
Show Abstract
Polarization maintaining buffered Fourier domain mode-locked swept source
Author(s): Jun Zhang; Joe Jing; Pinghe Wang; Zhongping Chen
Show Abstract
Broadband Fourier domain mode-locked laser for optical coherence tomography at 1060 nm
Author(s): Sebastian Marschall; Thomas Klein; Wolfgang Wieser; Teresa Torzicky; Michael Pircher; Benjamin R. Biedermann; Christian Pedersen; Christoph K. Hitzenberger; Robert Huber; Peter E. Andersen
Show Abstract
Long coherence length and linear sweep without an external optical k-clock in a monolithic semiconductor laser for inexpensive optical coherence tomography
Author(s): Jason Ensher; Paul Boschert; Katherine Featherston; Jonathan Huber; Michael Crawford; Michael Minneman; Chris Chiccone; Dennis Derickson
Show Abstract
In vivo intracardiac OCT imaging through percutaneous access: towards image guided radio-frequency ablation
Author(s): Hui Wang; Wei Kang; Thomas Carrigan; Austin Bishop; Noah Rosenthal; Mauricio Arruda; Andrew M. Rollins
Show Abstract
Advances in a fully integrated intravascular OCT-ultrasound system for cardiovascular imaging
Author(s): Joe Jing; Jiawen Li; Xiang Li; Jiechen Yin; Jun Zhang; Khiet Hoang; Pranav Patel; Qifa Zhou; Zhongping Chen
Show Abstract
Intensity-based modified Doppler variance algorithm dedicated for phase instable optical coherence tomography systems
Author(s): Gangjun Liu; Wangcun Jia; Danny Chou; Wenjuan Qi; Bernard Choi; Zhongping Chen
Show Abstract
Image guided 3D OCT for early diagnosis of carcinoma in situ of the bladder
Author(s): Hugang Ren; Ki Cheon Park; Rubin Pan; Kenneth Shroyer; Wayne Waltzer; Yingtian Pan
Show Abstract
Multi-MHz FDML OCT: snapshot retinal imaging at 6.7 million axial-scans per second
Author(s): Thomas Klein; Wolfgang Wieser; Raphael André; Tom Pfeiffer; Christoph M. Eigenwillig; Robert Huber
Show Abstract
Optical amplification of the signal and sensitivity of the ultrafast spectral domain optical coherence tomography at an A-scan rate of 10MHz in a wavelength region of 1300nm
Author(s): D. Choi; H. Hiro-oka; K. Shimizu; K. Ohbayashi
Show Abstract
Dual-depth SSOCT for simultaneous complex resolved anterior segment and conventional retinal imaging
Author(s): Al-Hafeez Dhalla; Theresa Bustamante; Derek Nanikivil; Hansford Hendargo; Ryan McNabb; Anthony Kuo; Joseph A. Izatt
Show Abstract
Doppler streak mode Fourier domain optical coherence tomography
Author(s): Rui Wang; Julie X. Yun; Richard Goodwin; Roger Markwald; Raymond B. Runyan; Bruce Gao
Show Abstract
Depth-ambiguity free or polarization sensitive optical frequency domain imaging using the Pancharatnam-Berry phase
Author(s): Norman Lippok; Stéphan Coen; Rainer Leonhardt; Poul Nielsen; Frédérique Vanholsbeeck
Show Abstract
Analysis of the signal fall-off in spectral domain optical coherence tomography systems
Author(s): M. Hagen-Eggert; P. Koch; G. Hüttmann
Show Abstract
Multiple-depth en face optical coherence tomography using active recirculation loops in the non-stationary state
Author(s): John A. Rogers; Adrian Bradu; Adrian Podoleanu
Show Abstract
Simultaneous dark-bright field swept source OCT for ultrasound detection
Author(s): Cedric Blatter; Branislav Grajciar; Boris Hermann; Robert Huber; Wolfgang Drexler; Rainer A. Leitgeb
Show Abstract
Optimizing magnetomotive contrast of SPIO-labeled platelets for thrombosis imaging in optical coherence tomography
Author(s): Amy L. Oldenburg; Dmitry Spivak; Gongting Wu; Frank Tsui; Thomas H. Fischer
Show Abstract
In vivo measurement of amplifying motion within the organ of Corti under sound stimulation using optical coherence tomography
Author(s): Niloy Choudhury; Fangyi Chen; Dingjun Zha; Anders Fridberger; Jiefu Zheng; Steven L. Jacques; Ruikang K. Wang; Alfred L. Nuttall
Show Abstract
Measuring the vibrational response of the mouse ear using coherently interleaved optical coherence tomography
Author(s): Ryan Shelton; Simon Gao; John S. Oghalai; Brian E. Applegate
Show Abstract
Spectral and time domain OCT: a tool for optimal imaging of biological samples
Author(s): Maciej Szkulmowski; Iwona Gorczynska; Daniel Szlag; Maciej Wojtkowski
Show Abstract
Imaging of photothermal tissue expansion via phase sensitive optical coherence tomography
Author(s): Hendrik Spahr; Linda Rudolph; Heike Müller; Reginald Birngruber; Gereon Hüttmann
Show Abstract
Absolute measurement of subnanometer scale vibration of cochlear partition of an excised guinea pig cochlea using spectral-domain phase-sensitive optical coherence tomography
Author(s): Hrebesh M. Subhash; Niloy Choudhury; Steven L. Jacques; Ruikang K. Wang; Fangyi Chen; Dingjun Zha; Alfred L. Nuttall
Show Abstract
Automated detection of chorio-scleral interface using polarization-sensitive optical coherence tomography
Author(s): Lian Duan; Masahiro Yamanari; Yoshiaki Yasuno
Show Abstract
Optical coherence microscopy for deep tissue imaging of the cerebral cortex with intrinsic contrast
Author(s): Vivek J. Srinivasan; Harsha Radhakrishnan; James Y. Jiang; Scott Barry; Alex E. Cable
Show Abstract
High resolution holoscopy
Author(s): Gesa Lilith Franke; Dierck Hillmann; Thorsten Claußen; Christian Lührs; Peter Koch; Gereon Hüttmann
Show Abstract
Morphological image analysis for classification of gastrointestinal tissues using optical coherence tomography
Author(s): P. Beatriz Garcia-Allende; Iakovos Amygdalos; Hiruni Dhanapala; Robert D. Goldin; George B. Hanna; Daniel S. Elson
Show Abstract
Graphics processing unit-based ultrahigh speed real-time multidimensional Fourier domain optical coherence tomography
Author(s): Kang Zhang; Jin U. Kang
Show Abstract
Digital refocusing in optical coherence tomography
Author(s): Alexander A. Moiseev; Grigory V. Gelikonov; Pavel A. Shilyagin; Dmitry A. Terpelov; Valentin M. Gelikonov
Show Abstract
Graphics processing unit-based dispersion encoded full-range frequency domain OCT
Author(s): Ling Wang; Boris Povazay; Jeremy A. Guggenheim; Wolfgang Drexler; Bernd Hofer
Show Abstract
Quantitative elastography of skin and skin lesion using phase-sensitive OCT (PhS-OCT) and surface wave method
Author(s): Chunhui Li; Guangying Guan; Zhihong Huang; Ruikang Wang
Show Abstract
Discretely swept optical coherence tomography system using super-structure grating distributed Bragg reflector lasers at 1561-1639nm
Author(s): D. Choi; R. Yoshimura; H. Hiro-Oka; H. Furukawa; A. Goto; N. Satoh; A. Igarashi; M. Nakanishi; K. Shimizu; K. Ohbayashi
Show Abstract
Depth profile absorber concentration reconstruction using photothermal optical coherence tomography
Author(s): Roberto Reif; Guangying Guan; Ruikang K. Wang
Show Abstract
Swept-source coherence-gated Shack-Hartmann wavefront sensor
Author(s): Jingyu Wang; Adrian Gh. Podoleanu
Show Abstract
Automatic three-dimensional registration of intra-vascular optical coherence tomography images for the clinical evaluation of stent implantation over time
Author(s): Giovanni J. Ughi; Tom Adriaenssens; Matilda Larsson; Christophe Dubois; Peter Sinnaeve; Mark Coosemans; Walter Desmet; Jan D'hooghe
Show Abstract
Resolution improvement in dual-band OCT by filling the spectral gap
Author(s): Peter Cimalla; Maria Gaertner; Julia Walther; Edmund Koch
Show Abstract
High-speed spectroscopic OCT around 1550 nm based on dual-band swept laser source
Author(s): Rui Zhu; Jianbing Xu; Chi Zhang; Edmund Y. Lam; Kenneth K. Y. Wong
Show Abstract
Microfluidics analysis of blood using joint spectral and time domain optical coherence tomography
Author(s): Danuta Bukowska; Maciej Szkulmowski; Iwona Gorczynska; Andrzej Kowalczyk; Maciej Wojtkowski
Show Abstract
Polarization-sensitive optical coherence tomography measurements with different phase modulation amplitude when using continuous polarization modulation
Author(s): Zenghai Lu; Deepa K. Kasaragod; Stephen J. Matcher
Show Abstract
Lateral resolution improvement in oversampled optical coherence tomography images assuming weighted oversampled multi-scatterer contributions
Author(s): Evgenia Bousi; Costas Pitris
Show Abstract
Correction of phase-error for phase-resolved k-clocked optical frequency domain imaging
Author(s): Jianhua Mo; Jianan Li; Johannes F. de Boer
Show Abstract
High-speed polarization sensitive optical coherence tomography for retinal diagnostics
Author(s): Biwei Yin; Bingqing Wang; Kalyanramu Vemishetty; Jim Nagle; Shuang Liu; Tianyi Wang; Henry G. Rylander; Thomas E. Milner
Show Abstract
Speckle reduction in swept source optical coherence tomography images with slow-axis averaging
Author(s): Ou Tan; Yan Li; Yimin Wang; Martin F. Kraus; Jonathan J. Liu; Benjamin Potsaid; Bernhard Baumann; James G. Fujimoto; David Huang
Show Abstract
Quantitative comparison of wavelength dependence on penetration depth and imaging contrast for ultrahigh-resolution optical coherence tomography using supercontinuum sources at five wavelength regions
Author(s): S. Ishida; N. Nishizawa
Show Abstract
Megahertz processing rate for Fourier domain optical coherence tomography using a graphics processing unit
Author(s): Yuuki Watanabe; Dai Kamiyama
Show Abstract
Quantitative comparison of hardware architectures for high-speed processing in optical coherence tomography
Author(s): Brian E. Applegate; Jesung Park; Esteban Carbajal; Darren Schmidt; Kalyanramu Vemishetty
Show Abstract
Improvement of coherence length in a 200-kHz swept light source equipped with a KTN deflector
Author(s): Shogo Yagi; Kazunori Naganuma; Tadayuki Imai; Yasuo Shibata; Jun Miyazu; Masahiro Ueno; Yuuichi Okabe; Yuzo Sasaki; Kazuo Fujiura; Masahiro Sasaura; Kazutoshi Kato; Masato Ohmi; Masamitsu Haruna
Show Abstract
Self-assembled quantum dot-based swept laser source for optical coherence tomography applications
Author(s): N. Peyvast; D. T. D. Childs; N. Krstajic; Z. Lu; S. J. Matcher; D. Livshits; A. Shkolnik; I. Krestnikov; R. A. Hogg
Show Abstract
Enhancement of the signal-to-noise ratio at depths in Fourier domain optical coherence tomography
Author(s): Adrian Bradu; Petr Bouchal; Adrian Gh. Podoleanu
Show Abstract
Quantitative analysis of cardiomyocyte dynamics with optical coherence phase microscopy
Author(s): Rehman Ansari; Redouane Aherrahrou; Zouhair Aherrahrou; Jeanette Erdmann; Gereon Hüttmann; Achim Schweikard
Show Abstract
Detailed software design of an ultra-parallel ultra-high speed SD-OCT for real-time 4D display at 12 volume/second
Author(s): H. Hiro-Oka; D. Choi; K. Shimizu; K. Ohbayashi
Show Abstract
High-power sweeping semiconductor light sources at 840 nm with up to 100 nm tuning range
Author(s): V. R. Shidlovskii; S. N. Ilchenko; A. A. Lobintsov; M. V. Shramenko; S. D. Yakubovich
Show Abstract
Complex conjugate term manipulation in optical frequency-domain imaging using the time-frequency distribution
Author(s): Norman Lippok; Stéphan Coen; Poul Nielsen; Frédérique Vanholsbeeck
Show Abstract
Dynamic analysis of mental sweating and the peripheral vessels for the activity of the autonomic nervous system by optical coherence tomography
Author(s): Masato Ohmi; Daisuke Takada; Yuki Wada; Masamitsu Haruna
Show Abstract
Optical coherence tomography-based angle-resolved backscattering studies on bovine tendon and cartilage
Author(s): Deepa K. Kasaragod; Zenghai Lu; Stephen J. Matcher
Show Abstract
Linear in-wavenumber optical spectrum registration in SD-OCT
Author(s): Grigory V. Gelikonov; Valentin M. Gelikonov; Pavel A. Shilyagin
Show Abstract
Polymer microlens fiber probe for common path optical coherence tomography
Author(s): Hai Xiao; Yinan Zhang; Edward Pienkowski; Tao Wei; Xinwei Lan
Show Abstract
Single-shot full complex spectrum spectrometer-based OCT with a single-line photodiode array
Author(s): Grigory V. Gelikonov; Valentin M. Gelikonov; Aleksandr A. Moiseev; Pavel A. Shilyagin
Show Abstract
Ex vivo optical coherence tomography imaging of larynx tissues using a forward-viewing resonant fiber-optic scanning endoscope
Author(s): R. Cernat; Y. Y. Zhang; A. Bradu; T. Tatla; P. J. Tadrous; X. D. Li; A. Gh. Podoleanu
Show Abstract
Parametric study of femtosecond inscription of microstructures for OCT artefact fabrication
Author(s): Janarthanan Rasakanthan; Graham Chun Bon Lee; Peter D. Woolliams; Kate Sugden
Show Abstract
Linewidth of swept laser source
Author(s): Haitham Omran; Sami Sakhawy; Mohamed Shalaby; Diaa Khalil
Show Abstract

© SPIE. Terms of Use
Back to Top