Share Email Print

Proceedings of SPIE Volume 0486

Medical Imaging and Instrumentation '84
Editor(s): James A. Mulvaney
Format Member Price Non-Member Price
Softcover $105.00 * $105.00 *

*Available as a photocopy reprint only. Allow two weeks reprinting time plus standard delivery time. No discounts or returns apply.

Volume Details

Volume Number: 0486
Date Published: 28 August 1984
Softcover: 32 papers (218) pages
ISBN: 9780892525218

Table of Contents
show all abstracts | hide all abstracts
Application Of A Digital Beam Attenuator To Chest Radiography
Author(s): Bruce H. Hasegawa; Shaikh Naimuddin; James T. Dobbins III; Walter W. Peppler; Jack T. Cusma; Michael S. Van Lysel; Jerry C. Lancaster; Ching-Shan Lee; Sabee Molloi; Charles A. Mistretta
Show Abstract
Variable-Thickness Chest Filtration: The Effect Of High Atomic Number Filter Materials
Author(s): Carl J. Vyborny; Heber MacMahon; Kunio Doi; Mircea Sabau
Show Abstract
The Effect Of Pixel Size On The Detection Rate Of Early Pulmonary Sarcoidosis In Digital Chest Radiographic Systems
Author(s): Heber MacMahon; Carl Vyborny; Gregory Powell; Kunio Doi; Charles E. Metz
Show Abstract
Results Of A Six-State Pilot Study To Collect Exposure, Technique And Processing Data In Chest Radiography
Author(s): P. F. Butler; B. J. Conway; O. H. Suleiman; G. H. Koustenis; C. K. Showalter
Show Abstract
Video Cameras For Medical Imaging
Author(s): John N. Sandrik
Show Abstract
Video Requirements For Digital Subtraction Angiography
Author(s): Horace H. Hines; J.Anthony Seibert; David J. Borger
Show Abstract
Trouble-Shooting Multiformat Camera Applications
Author(s): David H. Haddick
Show Abstract
Videotape Recorders-Their Care And Feeding
Author(s): James C. Lawson
Show Abstract
Quality Control Of Video Components And Display Devices
Author(s): Joel E. Gray; John Stears; Merrill Wondrow
Show Abstract
Video Standards And Performance Tests Of Video Systems
Author(s): John H. Harshbarger
Show Abstract
Smpte Test Pattern For Certification Of Medical Diagnostic Display Devices
Author(s): Kenneth G. Lisk
Show Abstract
Film-Screen Speed System Considerations
Author(s): R. S. Holland
Show Abstract
Crossover And MTF Characteristics Of A Tabular-Grain X-Ray Film
Author(s): K. E. Huff; P. W. Wagner
Show Abstract
Comparison Of Signal-To-Noise Ratios For Some New Screen-Film Systems
Author(s): Phillip C. Bunch
Show Abstract
The Impact Of Anti-Crossover Radiographic Film In Clinical Practice
Author(s): J. W. Gorski; J. Skucas
Show Abstract
Rotatable Spoke Fluoroscopic Test Object
Author(s): Robert J. Moore
Show Abstract
Blood Flow Determination Using IV DSA
Author(s): Charles R. Wilson; David Smith; W.Dennis Foley; Sabee Molloi
Show Abstract
Arterial Blood Flow Measurement Using Digital Subtraction Angiography (DSA)
Author(s): David K. Swanson; P.David Myerowitz; Michael S. Van Lysel; Walter W. Peppler; Barry L. Fields; Kim M. Watson; Julia O'Connor
Show Abstract
Digital Subtraction Angiography (DSA) Techniques For The Evaluation Of Breast Lesions
Author(s): Michael J. Flynn; Laurens Ackerman; Scott Wilderman; Roger Block; Christine Watt; Matt Burke; P. C. Shetty
Show Abstract
Evaluation Of Phantoms Designed For Digital Fluorographic Systems
Author(s): Pei-Jan Paul Lin
Show Abstract
X-Ray Imaging With Two-Dimensional Charge-Coupled Device (CCD) Arrays
Author(s): John M. Herron; William H. Kennedy; David Gur; Stephen L. Miller; Walter F. Good; Barbara C. Good; Richard E. Latchaw; Howard Yonas
Show Abstract
Film-Screen Digital Radiography
Author(s): R. P. Schwenker
Show Abstract
Screen-Film Mammography Update: X-Ray Units, Breast Compression, Grids, Screen-Film Characteristics, And Radiation Dose
Author(s): Arthur G. Haus
Show Abstract
A Skeptical Look At A (DIGITAL) Sacred Cow
Author(s): Joel E. Gray; Philip R. Karsell; Gilbert P. Becker; Dale G. Gehring
Show Abstract
The Use Of A Digital Store To Provide Pulsed Fluoroscopy And Stored Images During Gastro-Intestinal Examinations
Author(s): D. M. Hynes; E. W. Edmonds; J. A. Rowlands; W. Wong Pack
Show Abstract
Preliminary Clinical Studies Using A Self Scanning Lineak Diode Array To Obtain 1024 X 1024 Digital Radiographs
Author(s): Donald Sashin; B.Simon Slasky; Ernest J. Sternglass; Klaus M. Bron; John M. Herron; William H. Kennedy; Joseph W. Boyer; Bertram R. Girdany; Raymond W. Simpson; Joseph A. Horton
Show Abstract
Experience With The SMPTE Test Pattern In Quality Control Of Magnetic Resonance Images
Author(s): Michael J. Bronskill
Show Abstract
Motion Artifact In 2DFT MR Imaging
Author(s): A. D. Nelson; R. J. Alfidi; A. Lent; M. Clampitt; M. Kritzer; F. Miraldi; C. Schultz; S. Kopiwoda
Show Abstract
Absorption Of NMR Signals At High Frequencies In Physiological Phantoms
Author(s): R. Mark Henkelman; Michael J. Bronskiil; Patrick R. Goebel
Show Abstract
Video Recording Paper - Innovation In Video Recording
Author(s): Hanoch Shalit
Show Abstract
Effects Of The CT Display Window On Detectability Of Large And Small Lesions
Author(s): Dana A. Twible; Philip F. Judy; Richard G. Swensson
Show Abstract
Radiation Dose Levels Associated With Newer CT Scanner Units
Author(s): Ahren Jacobson; Roy P. Osborne
Show Abstract

© SPIE. Terms of Use
Back to Top