Share Email Print
cover

Proceedings Paper

Digital Characterization Of Clinical Mammographic Microcalcifications: Applications In Computer-Aided Detection
Author(s): Heang-Ping Chan; Kunio Doi; Kwok-Leung Lam; Carl J. Vyborny; Robert A. Schmidt; Charles E. Metz
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

As part of our ongoing effort to develop an automated computer scheme for the detection and analysis of microcalcifications in digital mammograms, we have analyzed the physical characteristics of microcalcifications from a data base of 39 clinical mammograms in patients undergoing breast biopsy. A signal-extraction method was developed for determination of the size, contrast, and signal-to-noise ratio (SNR) of each microcalcification from unprocessed mammograms. The average power spectrum of the microcalcifications thus extracted was compared to that of the mammographic background. Based on an analysis of these characteristics, we designed a new type of spatial filter, obtained as the difference between a matched filter and a box-rim filter, that can selectively preserve the frequency content of microcalcifications while suppressing the low-frequency background and high-frequency noise. The SNR of the microcalcifications is thereby enhanced. Signal-extraction tests that make use of the size, contrast, local frequency content, and clustering properties of microcalcifications were employed for further discrimination between true signals and normal mammographic structures or artifacts. In order to evaluate the potential clinical utility of our approach, we applied the program to 20 clinical mammograms that contained subtle clustered microcalcifications. These mammograms were not included in the data base mentioned above. The automated computer detection scheme provided a true-positive cluster detection rate of 90% at a false-positive detection rate of one-half cluster per image. These results demonstrate the feasibility of using computer methods to aid radiologists in screening of mammograms for subtle microcalcifications.

Paper Details

Date Published: 27 June 1988
PDF: 3 pages
Proc. SPIE 0914, Medical Imaging II, (27 June 1988); doi: 10.1117/12.968685
Show Author Affiliations
Heang-Ping Chan, The University of Chicago (United States)
Kunio Doi, The University of Chicago (United States)
Kwok-Leung Lam, The University of Chicago (United States)
Carl J. Vyborny, The University of Chicago (United States)
Robert A. Schmidt, The University of Chicago (United States)
Charles E. Metz, The University of Chicago (United States)


Published in SPIE Proceedings Vol. 0914:
Medical Imaging II
Samuel J. Dwyer; Roger H. Schneider; Roger H. Schneider; Samuel J. Dwyer; Samuel J. Dwyer; Roger H. Schneider, Editor(s)

© SPIE. Terms of Use
Back to Top