A new electron-optical image tube (the Photochron III) has been designed to achieve a time-resolution of 200 fs or less with high spatial and temporal resolutions over an extended field. Use for an ultra-rapid framing camera is also indicated. In both cases the dynamic range should be improved because of the high mean axial potential voltage employed in the electron-optical arrangement.

Paper Details

Date Published: 1 March 1983
PDF: 8 pages
Proc. SPIE 0348, 15th Intl Congress on High Speed Photography and Photonics, (1 March 1983); doi: 10.1117/12.967736