A passive visible to infrared image transducer is described which allows practical simulation of high resolution dynamic infrared imagery for the first time. A theoretical performance analysis is presented which indicates an MTF of 50% at 5 cycles/mm is achievable with a time response of less than 20 msec and a required input power of less than 2 mw/cm2 per simulated degree ΔT. Experimental results on working devices are reported which match theoretical predictions. Successful simulation of high speed real-world infrared imagery is described. Suggestions for future work are presented which should further enhance resolution and dynamic range.

Paper Details

Date Published: 24 June 1980
PDF: 9 pages
Proc. SPIE 0226, Infrared Imaging Systems Technology, (24 June 1980); doi: 10.1117/12.958734
Show Author Affiliations
Vincent T. Bly, U.S. Army Night Vision & Electro-Optics Laboratory (United States)


Published in SPIE Proceedings Vol. 0226:
Infrared Imaging Systems Technology
William L. Wolfe; Jerrold Zimmerman, Editor(s)