Wide bandwidth, high throughput monochromators for synchrotron radiation applications have been developed using Layered Synthetic Microstructures (LSM's). A double crystal LSM monochromator has been demonstrated with an energy resolution of 3% at 1.5 keV and a tuning range of 0.8 to 3.5 keV. In addition, techniques for extending the tuning range to lower energies as well as studies of substrate perfection using soft X-ray topography will be described.

Paper Details

Date Published: 6 May 1985
PDF: 8 pages
Proc. SPIE 0563, Applications of Thin Film Multilayered Structures to Figured X-Ray Optics, (6 May 1985); doi: 10.1117/12.949693
Show Author Affiliations
P. Pianetta, Stanford Synchrotron Radiation Laboratory (United States)
R. Redaelli, Stanford Synchrotron Radiation Laboratory (United States)
T. W. Barbee, Lawrence Livermore National Laboratory (United States)