Experiments show that optical fiber attenuation measurement systems used by many laboratories in China meet the requirements of standard measurement methods recommended by the International Telegraph and Telephone Consultative Committee (CCITT) and the International Electrotechnical Commission (IEC). A simplified, practical criterion for checking equilibrium mode distribution (EMD) has been obtained. Round-robin results show good agreement of attenuation measurement for six Chinese laboratories using this criterion.

Paper Details

Date Published: 19 November 1985
PDF: 4 pages
Proc. SPIE 0559, Fiber Optics: Short-Haul and Long-Haul Measurements and Applications III, (19 November 1985); doi: 10.1117/12.949590
Show Author Affiliations
Li Luo, Shanghai Institute of Testing Technology (China)
Jiang Tongcun, Shanghai Institute of Testing Technology (China)
Luo Ling, Shanghai Institute of Testing Technology (China)
Yang Shao, Shanghai Institute of Testing Technology (China)