Infrared detector applications often require detector sensitive areas that are as closely spaced as possible. In particular, imaging systems often need close-packed detectors in order to increase their resolution. The imaging/resolution performance of two-dimensional arrays may be limited by the fact that the electron-hole pairs created by an optical disturbance (detection) may diffuse long distances from where the electron-hole pair was created. Some results of measurements of crosstalk and out-of-field signals in InSb detectors specially fabricated for these measurements are given herein. The detector arrays were configured in a manner such that the measurements would allow differentiation between electrical and optical (carrier diffusion) crosstalk.

Paper Details

Date Published: 7 December 1988
PDF: 7 pages
Proc. SPIE 0972, Infrared Technology XIV, (7 December 1988); doi: 10.1117/12.948282
Show Author Affiliations
David S. Smith, Cincinnati Electronics Corporation (United States)
James T. Wimmers, Cincinnati Electronics Corporation (United States)