Share Email Print
cover

Proceedings Paper

Optical Triangulation Using A CCD Array With Sub-Pixel Resolution
Author(s): Robert Jones; Lucy Rowbotham; Michael Pritchett
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The design of an optical triangulation gauge based upon a linear CCD array operating with sub-pixel resolution is described . Experimental results are presented that demonstrate the basic performance characteristics of the system and its ability to perform rapid measurements on complex engineering objects with accuracies in the range 2 to 5 µm .