Share Email Print
cover

Proceedings Paper

Optical Triangulation Using A CCD Array With Sub-Pixel Resolution
Author(s): Robert Jones; Lucy Rowbotham; Michael Pritchett
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The design of an optical triangulation gauge based upon a linear CCD array operating with sub-pixel resolution is described . Experimental results are presented that demonstrate the basic performance characteristics of the system and its ability to perform rapid measurements on complex engineering objects with accuracies in the range 2 to 5 µm .

Paper Details

Date Published: 16 January 1989
PDF: 6 pages
Proc. SPIE 0954, Optical Testing and Metrology II, (16 January 1989); doi: 10.1117/12.947656
Show Author Affiliations
Robert Jones, Cambridge Consultants Ltd. (England)
Lucy Rowbotham, Cambridge Consultants Ltd. (England)
Michael Pritchett, Cambridge Consultants Ltd. (England)


Published in SPIE Proceedings Vol. 0954:
Optical Testing and Metrology II
Chander Prakash Grover, Editor(s)

© SPIE. Terms of Use