Continuous Monitoring Of Cardiogreen Removal By A Diseased Liver Using An Optical Sensor
Author(s): Masahiko Kanda; Kunihiko Taniguchi; Kunio Awazu; Yoshitaka Ishigami; Manabu Masuzawa; Hiroshi Abe
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A non-invasive monitoring instrument of Cardiogreen (Indocyanine green) dye removal by a liver, which uses a new optical sensor and analytical method, was developed. The optical sensor utilizes 2 light emitting diodes operating at 810 and 940 nm wavelength, and 1 photodiode to sample the transmittance of light through the tip of the index finger. Since the transmittance of light is affected most by changes in both blood volume and the concentration of the dye in blood, adequate analysis must be taken to eliminate the change of blood volume in vivo. Fortunately, for a wavelength near the 805 nm isobestic wavelength, the transmittance of light does not vary with hemoglobin oxygen saturation, however it varies with hemoglobin content. In addition, at 805 nm wavelength, absorption by the dye is quite high, but it is quite low at 940 nm wavelength. Accordingly, the authors developed a new analytical. method by using the transmittance of light measured through the tip of the index finger before and after the dye injection. As a result, the change of blood volume in vivo was eliminated by using the newly developed analytical method. Therefore, the dye information was only measured. A quantitative estimation of plasma disappearance rate (PDR) in hepatic diseased patients which was obtained using this instrument showed that PDR values concurred fairly well with the PDR values from the blood sampling method.

Paper Details

Date Published: 8 April 1988
PDF: 8 pages
Proc. SPIE 0904, Microsensors and Catheter-Based Imaging Technology, (8 April 1988); doi: 10.1117/12.945229
Show Author Affiliations
Masahiko Kanda, Sumitomo Electric Industries (Japan)
Kunihiko Taniguchi, Sumitomo Electric Industries (Japan)
Kunio Awazu, Sumitomo Electric Industries (Japan)
Yoshitaka Ishigami, Osaka National Hospital (Japan)
Manabu Masuzawa, Osaka National Hospital (Japan)
Hiroshi Abe, Osaka National Hospital (Japan)


Published in SPIE Proceedings Vol. 0904:
Microsensors and Catheter-Based Imaging Technology
Alan I. West, Editor(s)

© SPIE. Terms of Use
Back to Top