Share Email Print
cover

Proceedings Paper

Further Tests Of The GE 32 X 1 InSb CID Array At KPNO
Author(s): R. R. Joyce; A. M. Fowler
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

For several years, the R&D group at KPNO has been evaluating the performance of a 32 X 1 InSb CID array obtained from General Electric (Syracuse) under background conditions anticipated for ground-based astronomical spectroscopic applications. The array, consisting of 100 pm square pixels on 125 pm centers, is intended for use in a cryogenic grating spec-trometer over the range 1.3 - 5.2 pm, with resolving power X/n -100 - 1000. To summarize the results of this evaluation12 i , it was found that an operating temperature -15 K would permit the MOS silicon scanner to operate reliably (but with changes in procedure from 77 K operation) and reduce the thermal dark current to negligible values. Quantum efficiencies measured in the laboratory under these operating conditions ranged from -0.8 at 2.2 pm to 0.25 at 4.7 pm. The most serious problem encountered with this array is the significant delay in output response to incident flux under conditions of low background. This "response lag" could present linearity problems in spectroscopic applica-tions where the integration time is limited by a strong spectral feature or by the thermal background at the long wavelength end of the spectral region being measured. In the summer of 1983, the array was sent to GE for repair of the scanner; in the course of this repair, four dead pixels were removed from the readout sequence and additional CID pixels at one end of the array were connected to the scanner. Thus, the new 33-element scanner reads out a linear array subtending 37 pixels, with pixels 4, 15, 19, and 21 missing from the sequence. After this repair was completed, the array was mounted in a cryostat for an evaluation of its performance as an imager through broadband photometric filters. This paper will summarize the imaging test and further experiments on the response lag problem and will conclude with some initial results with the array operating in the cryogenic grating spectrometer.

Paper Details

Date Published: 8 November 1984
PDF: 8 pages
Proc. SPIE 0501, State-of-the-Art Imaging Arrays and Their Applications, (8 November 1984); doi: 10.1117/12.944678
Show Author Affiliations
R. R. Joyce, National Optical Astronomy Observatories (United States)
A. M. Fowler, National Optical Astronomy Observatories (United States)


Published in SPIE Proceedings Vol. 0501:
State-of-the-Art Imaging Arrays and Their Applications
Keith N. Prettyjohns, Editor(s)