Results Of A Six-State Pilot Study To Collect Exposure, Technique And Processing Data In Chest Radiography
Author(s): P. F. Butler; B. J. Conway; O. H. Suleiman; G. H. Koustenis; C. K. Showalter
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The routine measurement of exposures for a reference dimension patient in diagnostic radiology is regarded as an important part of an effective quality assurance program. The most frequent radiologic examination conducted in the United States is chest radiography. If manual techniques are used to conduct the exam, the procedure for measuring exposure to the reference patient is straight-forward. However, if automatic exposure controlled (AEC) techniques are used, a patient-equivalent chest phantom must be employed to reproducibly attenuate the x-ray beam. This is of particular importance if exposures are to be compared among AEC systems with different entrance x-ray spectra. Exposure monitoring is just part of the quality assurance story. Radiographic techniques, filtration, scatter reduction, film/screen use, and film processing performance (among other factors) must also be assessed, in order to effectively evaluate and modify these exposures so that they provide appropriate image quality. The first four factors are relatively easy to determine through measurement or documentation. Poor processor performance, potentially a major cause of abnormally high patient exposure, is more difficult to assess. We have designed, constructed and tested a Lucite/aluminum patient-equivalent attenuation chest phantom (LucAl) to use in the estimation of standard posteroanterior (22-23 cm) patient exposures for both manual and AEC chest systems. A sensitometric procedure that can be used to assess relative processor performance has also been developed. This paper describes these two procedures and their use in a six-State pilot study to monitor and evaluate exposure, technique and processor data in chest radiography. Results from approximately 200 chest systems will be summarized.

Paper Details

Date Published: 28 August 1984
PDF: 9 pages
Proc. SPIE 0486, Medical Imaging and Instrumentation '84, (28 August 1984); doi: 10.1117/12.943194
Show Author Affiliations
P. F. Butler, FDA, Center for Devices and Radiological Health (United States)
B. J. Conway, FDA, Center for Devices and Radiological Health (United States)
O. H. Suleiman, FDA, Center for Devices and Radiological Health (United States)
G. H. Koustenis, FDA, Center for Devices and Radiological Health (United States)
C. K. Showalter, FDA, Center for Devices and Radiological Health (United States)


Published in SPIE Proceedings Vol. 0486:
Medical Imaging and Instrumentation '84
James A. Mulvaney, Editor(s)

© SPIE. Terms of Use
Back to Top