Paper Abstract
When measurements are made during the production of integrated circuit wafers on wafers that are out of specification, the wafers are considered misprocessed. Measurement accu-racy must be better than the specification to assure that the measurements are not part of the misprocessing problem. Optical tools have been used in the past for these critical dimension (CD) measurements. These tools have evolved from optical filars to TV pattern recognition to stepping a PMT aperture. This has improved the repeatability of measuring a single site multiple times by many operators to ±0.04 pm, 3.0 σ or better. However, with CDs of 1.0 μm or less, optical tools are reaching their limits of usability.
Paper Details
Date Published: 15 October 1984
PDF: 3 pages
Proc. SPIE 0480, Integrated Circuit Metrology II, (15 October 1984); doi: 10.1117/12.943044
Published in SPIE Proceedings Vol. 0480:
Integrated Circuit Metrology II
Diana Nyyssonen, Editor(s)
PDF: 3 pages
Proc. SPIE 0480, Integrated Circuit Metrology II, (15 October 1984); doi: 10.1117/12.943044
Show Author Affiliations
Peter Grant, IBM General Technology Division (United States)
Tim Fahey, Nanometrics, Inc. (United States)
Published in SPIE Proceedings Vol. 0480:
Integrated Circuit Metrology II
Diana Nyyssonen, Editor(s)
© SPIE. Terms of Use