Share Email Print

Proceedings Paper

Calibration Of High-Temperature, Fiber-Optic, Microbend, Pressure Transducers
Author(s): J W Berthold; W L Ghering; D Varshneya
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We have measured the pressure response of a high-temperature pressure transducer fabricated from fused silica. This transducer uses a microbend fiber-optic sensor to measure diaphragm deflection. The transducer was characterized at pressures up to +690 kPa and tem-peratures to 540°C. The experimental data show approximately a linear dependence on the applied pressure when the microbend sensor is preloaded. This behavior agrees with the calcu-lated results for the linear deflection of a preloaded diaphragm with applied pressure. The experimental results showed a zero offset when the temperature was raised, and also the slope of the pressure response curve decreased with increasing temperature. The observed zero shift to 540°C was 15 times the theoretical predictions. The observed change in slope with temperature was about four times less than the slope at room temperature. These discrepancies have been attributed to the thermally induced radial tensile stress in the fused-silica assembly. These stresses were the result of the original pressure-sealing method that was used for pressure calibration. A modified pressure seal was used to eliminate the thermally induced stresses. Results of the tests performed at various temperatures showed much better agreement of the zero offset and the change in slope of the pressure-response curve with theoretical predictions. The transducer with the original pressure seal was insensitive to vibration over the frequency range from 50 Hz to 2500 Hz. The vibration response was less than 0.25% of the full-scale pressure response. When subjected to three times the design pressure, a permanent offset in the pressure-response curve was observed. This has been attributed to the change in the preload of the clamped fiber.

Paper Details

Date Published: 28 April 1987
PDF: 7 pages
Proc. SPIE 0718, Fiber Optic and Laser Sensors IV, (28 April 1987); doi: 10.1117/12.937510
Show Author Affiliations
J W Berthold, Babcock & Wilcox Research and Development Division (United States)
W L Ghering, Babcock & Wilcox Research and Development Division (United States)
D Varshneya, Teledyne Ryan Electronics (United States)