Share Email Print
cover

Proceedings Paper

Sensitivity investigation of intra-cavity absorption gas sensors based on erbium-doped fiber ring lasers
Author(s): Tie-gen Liu; Kun Liu; Jun-feng Jiang; Yi-mo Zhang
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The sensitivity is an important issue for intra-cavity absorption gas sensors (ICAGS). In this paper, the ICAGS based on erbium-doped fiber ring lasers (EDFRL) are modeled using propagation equations, from which the expressions of the signal-to-noise ratio (SNR) and the sensitivity of the system are deduced. The influence of the pump power and the total attenuation of the system on the performance of the ICAGS are simulated theoretically and measured experimentally. The absorption signal of acetylene is detected by adjusting the state of the system. And concentration calibration of acetylene is realized finally.

Paper Details

Date Published: 31 January 2012
PDF: 8 pages
Proc. SPIE 8351, Third Asia Pacific Optical Sensors Conference, 83511W (31 January 2012); doi: 10.1117/12.916042
Show Author Affiliations
Tie-gen Liu, Tianjin Univ. (China)
Ministry of Education (China)
Kun Liu, Tianjin Univ. (China)
Ministry of Education (China)
Jun-feng Jiang, Tianjin Univ. (China)
Ministry of Education (China)
Yi-mo Zhang, Tianjin Univ. (China)
Ministry of Education (China)