Share Email Print
cover

Proceedings Paper

Resolution enhancement of computed radiography images using two orthogonal tilts
Author(s): Steven I. Pollmann; Chris J. D. Norley; Xunhua Yuan; David W. Holdsworth
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Limitations to the spatial resolution of current digital x-ray systems are bounded by the physical characteristics of the xray detector. However, the need to image smaller structures provides motivation to develop high-resolution x-ray detector systems for use with computed radiographic, and tomographic x-ray systems. We report the implementation of a tilted detector technique (TDT) to attain near isotropic resolution enhancement by combining two orthogonal image views, acquired with existing detector hardware tilted at a fixed angle. Images were acquired using a ceiling-mounted x-ray unit (Proteus XR/a, GE Medical Systems, 50kVp, 250mAs). Images were digitized using a Fujifilm Capsula X CR system, from a 35×43cm detector cassette placed on an angulated stand, featuring a 3520×4280 image matrix with an in-plane pixel spacing of 0.1mm. Three images were acquired: two for use with our TDT; and one for comparison, with no detector tilt. Performance was determined by using two line-pair phantoms (Models 07-521 and 07-533, Nuclear Associates) placed orthogonally to each other in the field of view. Custom software corrected for perspective distortion, co-registered and combined the tilted-detector images into a single higher-resolution image. Following unwarping and co-registration, the limiting spatial resolution of an image obtained via the weighted combination of the two orthogonal views (8 lp/mm) is found to be superior to that of a single view acquired with no detector tilt (5 lp/mm). This novel technique shows significant improvement in the spatial resolution of x-ray image acquisitions, using existing x-ray components and detector hardware.

Paper Details

Date Published: 3 March 2012
PDF: 7 pages
Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 831313 (3 March 2012); doi: 10.1117/12.913321
Show Author Affiliations
Steven I. Pollmann, Robarts Research Institute (Canada)
Chris J. D. Norley, Robarts Research Institute (Canada)
Xunhua Yuan, Robarts Research Institute (Canada)
David W. Holdsworth, Robarts Research Institute (Canada)
The Univ. of Western Ontario (Canada)


Published in SPIE Proceedings Vol. 8313:
Medical Imaging 2012: Physics of Medical Imaging
Norbert J. Pelc; Robert M. Nishikawa; Bruce R. Whiting, Editor(s)

© SPIE. Terms of Use
Back to Top