Share Email Print
cover

Proceedings Paper

Analysis of electrodes' placement and deformation in deep brain stimulation from medical images
Author(s): Maroua Mehri; Florent Lalys; Camille Maumet; Claire Haegelen; Pierre Jannin
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Deep brain stimulation (DBS) is used to reduce the motor symptoms such as rigidity or bradykinesia, in patients with Parkinson's disease (PD). The Subthalamic Nucleus (STN) has emerged as prime target of DBS in idiopathic PD. However, DBS surgery is a difficult procedure requiring the exact positioning of electrodes in the pre-operative selected targets. This positioning is usually planned using patients' pre-operative images, along with digital atlases, assuming that electrode's trajectory is linear. However, it has been demonstrated that anatomical brain deformations induce electrode's deformations resulting in errors in the intra-operative targeting stage. In order to meet the need of a higher degree of placement accuracy and to help constructing a computer-aided-placement tool, we studied the electrodes' deformation in regards to patients' clinical data (i.e., sex, mean PD duration and brain atrophy index). Firstly, we presented an automatic algorithm for the segmentation of electrode's axis from post-operative CT images, which aims to localize the electrodes' stimulated contacts. To assess our method, we applied our algorithm on 25 patients who had undergone bilateral STNDBS. We found a placement error of 0.91±0.38 mm. Then, from the segmented axis, we quantitatively analyzed the electrodes' curvature and correlated it with patients' clinical data. We found a positive significant correlation between mean curvature index of the electrode and brain atrophy index for male patients and between mean curvature index of the electrode and mean PD duration for female patients. These results help understanding DBS electrode' deformations and would help ensuring better anticipation of electrodes' placement.

Paper Details

Date Published: 17 February 2012
PDF: 7 pages
Proc. SPIE 8316, Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling, 831632 (17 February 2012); doi: 10.1117/12.912225
Show Author Affiliations
Maroua Mehri, INSERM (France)
IRISA, CNRS, Univ. de Rennes 1 (France)
Florent Lalys, INSERM (France)
IRISA, CNRS, Univ. de Rennes 1 (France)
Camille Maumet, INSERM (France)
IRISA, CNRS, Univ. de Rennes 1 (France)
Claire Haegelen, INSERM (France)
IRISA, CNRS, Univ. de Rennes 1 (France)
Pontchaillou Univ. Hospital (France)
Pierre Jannin, INSERM (France)
IRISA, CNRS, Univ. de Rennes 1 (France)


Published in SPIE Proceedings Vol. 8316:
Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling
David R. Holmes; Kenneth H. Wong, Editor(s)

© SPIE. Terms of Use
Back to Top