Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods
Author(s): Yahui Peng; Yulei Jiang; Fatma Nur Soylu; Mark Tomek; William Sensakovic; Aytekin Oto
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

Paper Details

Date Published: 28 February 2012
PDF: 6 pages
Proc. SPIE 8318, Medical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment, 83181H (28 February 2012); doi: 10.1117/12.911637
Show Author Affiliations
Yahui Peng, The Univ. of Chicago (United States)
Yulei Jiang, The Univ. of Chicago (United States)
Fatma Nur Soylu, The Univ. of Chicago (United States)
Mark Tomek, The Univ. of Chicago (United States)
William Sensakovic, The Univ. of Chicago (United States)
Aytekin Oto, The Univ. of Chicago (United States)


Published in SPIE Proceedings Vol. 8318:
Medical Imaging 2012: Image Perception, Observer Performance, and Technology Assessment
Craig K. Abbey; Claudia R. Mello-Thoms, Editor(s)

© SPIE. Terms of Use
Back to Top