Low-dose and scatter-free cone-beam CT imaging: a preliminary study
Author(s): Xue Dong; Xun Jia; Tianye Niu; Lei Zhu
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Clinical applications of CBCT imaging are still limited by excessive imaging dose from repeated scans and poor image quality mainly due to scatter contamination. Compressed sensing (CS) reconstruction algorithms have shown promises in recovering faithful signals from low-dose projection data, but do not serve well the needs of accurate CBCT imaging if effective scatter correction is not in place. Scatter can be accurately measured and removed using measurement-based methods. However, in conventional FDK reconstruction, these approaches are considered unpractical since they require multiple scans or moving the beam blocker during the data acquisition to compensate for the inevitable primary loss. In this work, we combine the measurement-based scatter correction and CS-based iterative reconstruction algorithm, such that scatter-free images can be obtained from low-dose data. We lower the CBCT dose by reducing the projection number and inserting lead strips between the x-ray source and the object. The insertion of lead strips also enables scatter measurement on the measured samples inside the strip shadows. CS-based iterative reconstruction is finally carried out to obtain scatter-free and low-dose CBCT images. Simulation studies are designed to optimize the lead strip geometry for a certain dose reduction ratio. After optimization, our approach reduces the CT number error from over 220HU to below 5HU on the Shepp-Logan phantom, with a dose reduction of ~80%. With the same dose reduction and the optimized method parameters, the CT number error is reduced from 242HU to 20HU in the selected region of interest on Catphan©600 phantom.

Paper Details

Date Published: 9 March 2012
PDF: 11 pages
Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 831319 (9 March 2012); doi: 10.1117/12.911596
Show Author Affiliations
Xue Dong, Georgia Institute of Technology (United States)
Xun Jia, Univ. of California, San Diego (United States)
Tianye Niu, Georgia Institute of Technology (United States)
Lei Zhu, Georgia Institute of Technology (United States)


Published in SPIE Proceedings Vol. 8313:
Medical Imaging 2012: Physics of Medical Imaging
Norbert J. Pelc; Robert M. Nishikawa; Bruce R. Whiting, Editor(s)

© SPIE. Terms of Use
Back to Top