An image registration based ultrasound probe calibration
Author(s): Xin Li; Dinesh Kumar; Saradwata Sarkar; Ram Narayanan
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation σtranslation = 0.50 mm, σrotation = 0.52 degree) compared to the manual approach (pooled standard deviation σtranslation = 0.62 mm, σrotation = 0.78 degree).

Paper Details

Date Published: 14 February 2012
PDF: 8 pages
Proc. SPIE 8314, Medical Imaging 2012: Image Processing, 831423 (14 February 2012); doi: 10.1117/12.911461
Show Author Affiliations
Xin Li, Eigen Inc. (United States)
Dinesh Kumar, Eigen Inc. (United States)
Saradwata Sarkar, Eigen Inc. (United States)
Ram Narayanan, Eigen Inc. (United States)


Published in SPIE Proceedings Vol. 8314:
Medical Imaging 2012: Image Processing
David R. Haynor; Sébastien Ourselin, Editor(s)

© SPIE. Terms of Use
Back to Top