Share Email Print
cover

Proceedings Paper

Fast CT-CT fluoroscopy registration with respiratory motion compensation for image-guided lung intervention
Author(s): Po Su; Zhong Xue; Kongkuo Lu; Jianhua Yang; Stephen T. Wong
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

CT-fluoroscopy (CTF) is an efficient imaging method for guiding percutaneous lung interventions such as biopsy. During CTF-guided biopsy procedure, four to ten axial sectional images are captured in a very short time period to provide nearly real-time feedback to physicians, so that they can adjust the needle as it is advanced toward the target lesion. Although popularly used in clinics, this traditional CTF-guided intervention procedure may require frequent scans and cause unnecessary radiation exposure to clinicians and patients. In addition, CTF only generates limited slices of images and provides limited anatomical information. It also has limited response to respiratory movements and has narrow local anatomical dynamics. To better utilize CTF guidance, we propose a fast CT-CTF registration algorithm with respiratory motion estimation for image-guided lung intervention using electromagnetic (EM) guidance. With the pre-procedural exhale and inhale CT scans, it would be possible to estimate a series of CT images of the same patient at different respiratory phases. Then, once a CTF image is captured during the intervention, our algorithm can pick the best respiratory phase-matched 3D CT image and performs a fast deformable registration to warp the 3D CT toward the CTF. The new 3D CT image can be used to guide the intervention by superimposing the EM-guided needle location on it. Compared to the traditional repetitive CTF guidance, the registered CT integrates both 3D volumetric patient data and nearly real-time local anatomy for more effective and efficient guidance. In this new system, CTF is used as a nearly real-time sensor to overcome the discrepancies between static pre-procedural CT and the patient's anatomy, so as to provide global guidance that may be supplemented with electromagnetic (EM) tracking and to reduce the number of CTF scans needed. In the experiments, the comparative results showed that our fast CT-CTF algorithm can achieve better registration accuracy.

Paper Details

Date Published: 17 February 2012
PDF: 8 pages
Proc. SPIE 8316, Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling, 83161J (17 February 2012); doi: 10.1117/12.910822
Show Author Affiliations
Po Su, Northwestern Polytechnical Univ. (China)
The Methodist Hospital Research Institute (United States)
Zhong Xue, The Methodist Hospital Research Institute (United States)
Kongkuo Lu, Philips Research North America (United States)
Jianhua Yang, Northwestern Polytechnical Univ. (China)
Stephen T. Wong, The Methodist Hospital Research Institute (United States)


Published in SPIE Proceedings Vol. 8316:
Medical Imaging 2012: Image-Guided Procedures, Robotic Interventions, and Modeling
David R. Holmes; Kenneth H. Wong, Editor(s)

© SPIE. Terms of Use
Back to Top