In order to decrease the patient's radiation exposure from Computed Tomography, the new CT geometry CTDOR has been invented. It consists of two data sets: A conventional arc or flat panel detector and a mask ring with shieldings on the outside and detectors on the inside separated by windows. Combined with the reconstruction algorithm OPED, it has the theoretical potential to decrease the dose about 50% while providing the same image quality as conventional systems. First steps to evaluate this theory were done with a mask ring demonstrator combined with a conventional C-arm device. Although the quality of the demonstrator is limited, this set-up was supposed to demonstrate how the combination of the two data sets works in principle. Preliminary results from earlier studies, however, provided images of rather poor quality. This work presents better images obtained with an optimized data treatment. We showed that most artifacts are eliminated and that we get sharper images with higher contrast compared to the images reconstructed from the single data sets and compared to the earlier study. Regarding the limitations of the set-up, the resulting images were remarkably good. CTDOR is therefore a promising method, which is worth to perform further studies.

Paper Details

Date Published: 3 March 2012
PDF: 13 pages
Proc. SPIE 8313, Medical Imaging 2012: Physics of Medical Imaging, 83132M (3 March 2012); doi: 10.1117/12.908231
Show Author Affiliations
Claudia C. Brunner, Helmholtz Zentrum München GmbH (Germany)
U.S. Food and Drug Administration (United States)
Oleg Tischenko, Helmholtz Zentrum München GmbH (Germany)
Hugo de las Heras, Helmholtz Zentrum München GmbH (Germany)
Quart GmbH (Germany)
Bernhard Renger, Klinikum rechts der Isar der Technischen Univ. München (Germany)
Helmut Schlattl, Helmholtz Zentrum München GmbH (Germany)
Christoph Hoeschen, Helmholtz Zentrum München GmbH (Germany)


Published in SPIE Proceedings Vol. 8313:
Medical Imaging 2012: Physics of Medical Imaging
Norbert J. Pelc; Robert M. Nishikawa; Bruce R. Whiting, Editor(s)

© SPIE. Terms of Use
Back to Top