In vitro observation of cartilage-degeneration progression by Fourier-domain OCT
Author(s): Ulrich Marx; Robert Schmitt; Sven Nebelung; Markus Tingart; Christian Lüring; Björn Rath
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Optical Coherence Tomography (OCT) as emerging clinical diagnostic imaging technology for dermatology and other semitransparent tissues has shown high potential in monitoring and evaluating the inner structure of articular cartilages. Since novel therapies for the limitation of cartilage degeneration in early stages of osteoarthritis are available, the early minimal invasive diagnosis of cartilage degradation is clinically essential for further treatment options. With the advancing performance and thus diagnostic opportunities of 3D-OCT devices, we carried out a systematic study by monitoring arthrotic alterations of porcine osteochondral explants that are mechanically induced under traumatic impaction. As for in-vitro tomographic imaging we utilized two OCT devices, a Thorlabs FD-OCT device with 92KHz A-scan rate and 1310nm as central wavelength and a self-developed FD-OCT device at 840nm central wavelength. This allows the comparison in image contrast and optical penetration of cartilage tissue between these two spectral bandwidths. Further we analyzed human biopsies of articular cartilages with various degrees of osteoarthritis. The 2D and 3D OCT tomograms are characterized qualitatively regarding the inner tissue structure and quantitatively regarding the tissue absorption parameters. Therefore, we are developing image processing algorithms for the automated monitoring of cartilage tissue. A scoring system for 3D-monitoring allows the characterization of the probe volume regarding the morphological structure and tissue compactness by processing the C - scan data.

Paper Details

Date Published: 28 February 2012
PDF: 7 pages
Proc. SPIE 8214, Advanced Biomedical and Clinical Diagnostic Systems X, 82140X (28 February 2012); doi: 10.1117/12.907756
Show Author Affiliations
Ulrich Marx, Fraunhofer Institute for Production Technology (Germany)
Robert Schmitt, Fraunhofer Institute for Production Technology (Germany)
RWTH Aachen Univ. (Germany)
Sven Nebelung, Aachen Univ. Hospital (Germany)
Markus Tingart, Aachen Univ. Hospital (Germany)
Christian Lüring, Aachen Univ. Hospital (Germany)
Björn Rath, Aachen Univ. Hospital (Germany)


Published in SPIE Proceedings Vol. 8214:
Advanced Biomedical and Clinical Diagnostic Systems X
Tuan Vo-Dinh; Anita Mahadevan-Jansen; Warren S. Grundfest, Editor(s)