An encapsulated fiber optic fuel level sensor
Author(s): D. Sengupta; M. Sai Shankar; P. Saidi Reddy; R. L. N. Sai Prasad; K. S. Kamineni; P. Kishore
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

An encapsulated fiber optic sensor head for the detection of level of fuel in a tank is presented. The design is based on a concentric cam used along with a float and extrinsic intensity modulation of light. The sensor has been tested for its performance to measure a fuel level range of 35cm and a sensitivity of 0.2316 volts/cm was observed during rise in fuel level. The sensitivity and range of level sensing can be varied by varying the length of the connecting rod.

Paper Details

Date Published: 26 July 2011
PDF: 6 pages
Proc. SPIE 8001, International Conference on Applications of Optics and Photonics, 80013Y (26 July 2011); doi: 10.1117/12.892011
Show Author Affiliations
D. Sengupta, National Institute of Technology, Warangal (India)
M. Sai Shankar, National Institute of Technology, Warangal (India)
P. Saidi Reddy, National Institute of Technology, Warangal (India)
R. L. N. Sai Prasad, National Institute of Technology, Warangal (India)
K. S. Kamineni, National Institute of Technology, Warangal (India)
P. Kishore, National Institute of Technology, Warangal (India)