Share Email Print
cover

Proceedings Paper

State of polarization mapping using a calibrated interferometric polarimeter
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We propose a simple scheme for accurate state of polarization (SOP) mapping with an interferometric polarimeter using Fourier transform method of fringe analysis. In single shot polarimeters that use Fourier transform method of fringe analysis, a spatial carrier frequency is introduced in the fringes of recorded interferogram either by introducing the relative tilt between the sample beam under test and a reference beam, as demonstrated by Ohtsuka and Oka or by passing the sample beam through birefringent optical components such as Wollaston prisms as demonstrated by Oka and Kaneko. In this technique, the amount of spatial carrier frequency that enabled to filter different terms in the Fourier spectrum of the recorded interferogram had to be calibrated with the use of light with a known SOP. Even in this case, the spatial carrier frequency introduced in the recorded interferogram is influenced by the relative tilt of the beam used for calibration. To eliminate the linear phase introduced by spatial carrier frequency, usually the spectrum around the carrier frequency location in the Fourier transform is shifted and brought to the centre. During this process an error of a fraction of a pixel in the shifting of the spectrum after filtering to remove the linear phase introduced by spatial carrier frequency will drastically change the measured SOP of light. For accurate SOP mapping, it is important that we eliminate the artifacts and errors due to the spatial carrier frequency in the single shot polarimeter that are otherwise very promising. In the present work, we propose a Mach-Zehnder interferometric polarimeter that uses a common path Sagnac interferometer to generate reference beams with orthogonal state of polarization. By taking advantage of the inherent stability of the proposed common path Sagnac interferometer against surrounding vibrations and air turbulences, a simple calibration scheme using a light of known state of polarization is used to map the state of polarization with better accuracy.

Paper Details

Date Published: 27 May 2011
PDF: 7 pages
Proc. SPIE 8082, Optical Measurement Systems for Industrial Inspection VII, 80821T (27 May 2011); doi: 10.1117/12.888964
Show Author Affiliations
Dinesh N. Naik, The Univ. of Electro-Communications (Japan)
Rakesh Kumar Singh, The Univ. of Electro-Communications (Japan)
Hitoshi Itou, The Univ. of Electro-Communications (Japan)
Yoko Miyamoto, The Univ. of Electro-Communications (Japan)
Mitsuo Takeda, The Univ. of Electro-Communications (Japan)


Published in SPIE Proceedings Vol. 8082:
Optical Measurement Systems for Industrial Inspection VII
Peter H. Lehmann; Wolfgang Osten; Kay Gastinger, Editor(s)

© SPIE. Terms of Use
Back to Top