Share Email Print
cover

Proceedings Paper

Detection of cancer cells in prostate tissue with time-resolved fluorescence spectroscopy
Author(s): C. E. Gerich; J. Opitz; M. Toma; M. Sergon; S. Füssel; R. Nanke; J. Fehre; M. Wirth; G. Baretton; J. Schreiber
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Goals: Improving cancer diagnosis is one of the important challenges at this time. The precise differentiation between benign and malignant tissue is in the oncology and oncologic surgery of the utmost significance. A new diagnostic system, that facilitates the decision which tissue has to be removed, would be appreciated. In previous studies many attempts were made to use tissue fluorescence for cancer recognition. However, no clear correlation was found between tissue type and fluorescence parameters like time and wavelength dependent fluorescence intensity I(t, λ). The present study is focused on cooperative behaviour of cells in benign or malignant prostates tissue reflecting differences in their metabolism. Material and Methods: 50 prostate specimens were obtained directly after radical prostatectomy and from each specimen 6 punch biopsies were taken. Time-resolved fluorescence spectra were recorded for 4 different measurement points for each biopsy. The pathologist evaluated each measurement point separately. An algorithm was developed to determine a relevant parameter of the time dependent fluorescence data (fractal dimension DF ). The results of the finding and the DF -value were correlated for each point and then analysed with statistical methods. Results: A total of 1200 measurements points were analysed. The optimal algorithm and conditions for discrimination between malignant and non-malignant tissue areas were found. The correct classification could be stated in 93.4% of analysed points. The ROC-curve (AUC = 0.94) confirms the chosen statistical method as well as it informs about the specificity (0.94) and sensitivity (0.90). Conclusion: The new method seems to offer a very helpful diagnostic tool for pathologists as well as for surgery.

Paper Details

Date Published: 23 February 2011
PDF: 12 pages
Proc. SPIE 7897, Optical Interactions with Tissue and Cells XXII, 78970R (23 February 2011); doi: 10.1117/12.876094
Show Author Affiliations
C. E. Gerich, Fraunhofer-Institut für Zerstörungsfreie Prüfverfahren (Germany)
J. Opitz, Fraunhofer-Institut für Zerstörungsfreie Prüfverfahren (Germany)
M. Toma, Universitätsklinikum Carl Gustav Carus Dresden (Germany)
M. Sergon, Universitätsklinikum Carl Gustav Carus Dresden (Germany)
S. Füssel, Universitätsklinikum Carl Gustav Carus Dresden (Germany)
R. Nanke, Siemens AG (Germany)
J. Fehre, Siemens AG (Germany)
M. Wirth, Universitätsklinikum Carl Gustav Carus Dresden (Germany)
G. Baretton, Universitätsklinikum Carl Gustav Carus Dresden (Germany)
J. Schreiber, Fraunhofer-Institut für Zerstörungsfreie Prüfverfahren (Germany)


Published in SPIE Proceedings Vol. 7897:
Optical Interactions with Tissue and Cells XXII
E. Duco Jansen; Robert J. Thomas, Editor(s)

© SPIE. Terms of Use
Back to Top